Physical Property Testing Instruments
Filter
Showing 7111–7140 of 12456 results
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NXL Desktop Large-Cavity Micro-CT |
| Detector Type | Flat-Panel Detector |
| Scanning Method | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| X-ray Energy | 150 kV |
| Spatial Resolution | 5 µm |
| Maximum Sample Dimensions | 320 mm × 540 mm |
| Dimensional Measurement Accuracy | 2.5 µm |
| Maximum Sample Weight | 40 kg |
| Equipment Dimensions | 1500 × 791 × 720 mm |
| X-ray Source | 150 kV / 75 W Microfocus |
| Detector Resolution | 13.5 MP, 14-bit Dynamic Range |
| Scan Modes | Circular Scan, Automated Stitching, Helical Scan |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Model | NES 713 |
| Compliance Standard | NES 713 (Naval Engineering Standard) |
| Operating Temperature | 800 °C |
| Chamber Volume | V m³ (user-specified per configuration) |
| Sample Mass | 100 g (standard test mass) |
| Toxicity Index Calculation | Σ(C₈ᵢ / Cfᵢ), i = 1 to n |
| Observation Window | Reinforced PTFE-coated polycarbonate viewport |
| Exhaust Control | Timer-actuated automatic purge mode |
| Test Modes | Manual and programmable automatic cycle |
| Chamber Lining | PTFE-bonded stainless steel interior |
| Door Mechanism | Positive-seal dual-latch system |
| Ignition System | Electric spark ignition with auto-shutoff |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | APTAC 264 |
| Temperature Range | RT to 500 °C |
| Temperature Tracking Rate | 0–400 °C/min |
| Minimum Detectable Heat Flow Rate | 0.002 °C/min |
| Pressure Range | 0–140 bar |
| Pressure Tracking Rate | 0–680 bar/min |
| Standard Functions | Integrated Stirring, Liquid Injection, and Effluent Discharge |
| Optional Feature | VARIPHI™ Thermal Inertia Compensation Technology |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | ARC 244 |
| Temperature Range | RT to 500 °C |
| Temperature Tracking Rate | 0–20 °C/min |
| Minimum Detectable Heat Flow Rate | 0.01 °C/min |
| Pressure Range | 0–200 bar |
| Optional Features | Integrated Stirring, Venting Module, VARIPHI™ Thermal Inertia Compensation Technology |
| Safety Architecture | Dual-Redundant Interlock System, Top-Lifting Furnace Assembly, Tubular Heater Design for Minimized Thermal Backflow |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | ARC254 |
| Temperature Range | RT to 500°C |
| Temperature Tracking Rate | 0–200°C/min |
| Minimum Detectable Heat Flow Rate | 0.01°C/min |
| Pressure Range | 0–200 bar |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter |
| Optional Accessories | VARIPHI™ Technology Module, Stirring/Injection/Emission Units, Battery Test Fixture, Nail Penetration Fixture for Li-ion Cells |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DEA 288 |
| Frequency Range | 0.001–1 MHz |
| Resistivity Measurement Range | 10⁰–10¹⁶ Ω·cm (sensor-dependent) |
| Data Channels | 1–16 (configurable) |
| Configuration Options | Portable Version or Industrial Rack-Mounted Version |
| Sensor Compatibility | In-mold, embedded, and lab-grade dielectric sensors |
| Environmental Test Capabilities | Compatible with heating/cooling stages, hot presses, humidity chambers, and UV irradiation systems |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Classic |
| Temperature Range | RT to 1600 °C |
| Heating Rate | 0–50 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±5000 µm |
| Resolution | 2 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Classic |
| Temperature Range | RT to 1600°C |
| Heating Rate | 0.001–50°C/min |
| Temperature Accuracy | ±0.1°C |
| Sample Length | 25–50 mm |
| Atmosphere Control | Integrated MFC (1 standard, up to 3 optional) |
| Vacuum Capability | Sealed vacuum chamber (optional auto-vacuum) |
| Force Control | Programmable contact force with stepwise or linear ramping |
| Displacement Resolution | 2 nm (NanoEye optical encoder) |
| 炉体配置 | Single-furnace integrated design |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045, USP <671> |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Select |
| Temperature Range | −180 °C to 2000 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±10,000 µm / ±25,000 µm |
| Resolution | 1 nm / 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Force Control | Adjustable from 10 mN to 3 N (optional) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Supreme HT |
| Temperature Range | −180 to 2800 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±25,000 µm |
| Resolution | 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum (down to 10⁻⁵ mbar) |
| Furnace Types | Graphite, Alumina, Fused Silica |
| Optional Features | c-DTA® (calibrated Differential Thermal Analysis), Identify™ Spectral Matching, Rate-Controlled Sintering (RCS) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Supreme |
| Temperature Range | −180 to 2800 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±25,000 µm |
| Resolution | 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Force Control | Adjustable from 10 mN to 3 N (optional) |
| Sample Types | Solid, Powder, Liquid |
| Furnace Configurations | Single or dual interchangeable furnaces |
| Patented Technologies | NanoEye displacement sensor, MultiTouch sample positioning, c-DTA® (optional), Identify spectral library (optional), Rate-Controlled Sintering (RCS, optional) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DMA 242 E |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Static Force Range | 12 N (up to 24 N with optional configuration) |
| Dynamic Force Range | 12 N (up to 24 N with optional configuration) |
| Displacement Range | 20 mm |
| Frequency Range | 0.01–100 Hz |
| Strain Control Range | ±240 µm |
| Modulus Range | 10⁻³–10⁶ MPa |
| Damping Factor (tan δ) Range | 0.005–100 |
| Cooling Options | Liquid Nitrogen (to −170 °C) or Vortex-Tube Compressed Air (to 0 °C) |
| Deformation Modes | 3-Point Bending, Single/Double Cantilever, Shear, Tension, Compression/Indentation |
| Additional Modes | TMA, Creep/Relaxation, Stress/Strain Sweep |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DMA 303 Eplexor |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −170 °C to 800 °C |
| Temperature Accuracy | ±0.1 °C |
| Force Range | 1 mN to 50 N |
| Displacement Range | 30 mm |
| Frequency Range | 0.001 Hz to 150 Hz |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 F1 Phoenix |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –180 °C to 700 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0 to 200 K/min |
| Sensor Options | τ-type (time constant 0.6 s), μ-type (high-sensitivity) |
| Cooling Options | Liquid nitrogen (LN₂), mechanical refrigeration (–85 °C to 600 °C), compressed air, cooling cup |
| Sample Capacity | Multi-sample capability (optional 64-position ASC auto-sampler) |
| Atmosphere Control | Integrated mass flow controller, gas-tight furnace design compatible with FTIR/MS coupling |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 F1 |
| Temperature Range | −180 °C to 700 °C |
| Heating/Cooling Rate | 0–200 K/min |
| Sensor Options | τ-type (time constant: 0.6 s), μ-type (ultra-high sensitivity) |
| Cooling Options | Liquid nitrogen (LN₂), mechanical refrigeration (−85 °C to 600 °C), compressed air, cooling cup |
| Gas Control | Dual purge + single protective gas channels with integrated mass flow controllers |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 HP |
| Temperature Range | –150 °C to 600 °C (with CC 200L cryo-cooler) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Pressure Range | Vacuum to 15 MPa (150 bar) |
| Pressure Resolution | 0.002 MPa |
| Gas Flow Control | Up to 500 mL/min |
| Atmosphere Options | N₂, Ar, He, O₂, H₂, CO₂, CH₄, air, and custom gas mixtures |
| Sensor Type | Interchangeable high-stability DSC sensors |
| Furnace | Gold-plated corrosion-resistant cell |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 HP Phoenix |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –150 °C to 600 °C (under vacuum to 15 MPa) |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–100 K/min |
| Pressure Range | 0–15 MPa (0–150 bar) |
| Atmosphere Compatibility | Static or dynamic O₂, N₂, Ar, He, H₂, CO₂, CH₄, and other process gases |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0 to 500 °C/min |
| Detection Limit | 0.1 μW |
| Atmosphere Control | Dynamic or static inert, reducing, or oxidizing (automated gas switching) |
| Cooling Options | Compressed air, mechanical refrigeration, liquid nitrogen (dual-cooling system optional, software-switchable) |
| Optional Accessories | Photo-DSC module, ASC automatic sample changer (20 positions), TMDSC upgrade |
| Software Features | Intelligent Mode, Expert Mode, Auto-Calibration, Auto-Analysis, Pattern Recognition, Tau-R® advanced thermal lag correction, DSC spectral database and search engine |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 214 Polyma |
| Temperature Range | −170 °C to 600 °C / 700 °C (depending on furnace) |
| Temperature Accuracy | ±0.1 °C (against standard metals) |
| Heating/Cooling Rate | 0.001–500 K/min |
| Baseline Drift | 10 μW (−50 °C to 300 °C) |
| DSC Signal Range | ±750 mW |
| Enthalpy Sensitivity | 0.1 μW |
| Enthalpy Accuracy | ±0.05% (against standard metals) |
| Thermal Response Ratio | >100 mW/K |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Classic |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −170 °C to 600 °C |
| Heating/Cooling Rate | 0.001–100 K/min |
| Temperature Accuracy | ±0.1 K (intrinsic) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Supreme-H |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | −180 °C to 750 °C |
| Heating/Cooling Rate | 0 to 200 K/min |
| Module Architecture | Interchangeable Multi-Module Platform |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (with optional software package) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris® Select-P |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –170 to 600 °C |
| Heating/Cooling Rate | 0 to 500 K/min |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (software-enabled), ISO 11357, ASTM E794, ASTM E1356 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 to 650 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Module Configuration | Sensor + Furnace Assembly (S-Module) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (with optional software package) |
| Key Software Features | BeFlat®, Tau-R Correction, TM-DSC (optional), Automatic Baseline Subtraction, Crystallinity Calculation, Cp Measurement |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 3500 Sirius |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Sample Capacity (with ASC) | Up to 20 positions (samples + references) |
| Instrument Type | Differential Scanning Calorimeter |
| 炉 Body Material | Silver-based furnace block |
| Sensor Architecture | Monolithic sensor design |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 3500 Sirius |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0.001–100 K/min (temperature-dependent) |
| Sensor Type | Heat-Flow |
| Calorimetric Range | ±650 mW |
| Enthalpy Accuracy | ±1% (vs. certified metals) |
| Atmosphere Options | Oxidizing or inert (static/dynamic) |
| ASC Capacity | Up to 20 sample/reference positions (optional) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F1 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Sensor Types | Replaceable DSC (−150 to 1650 °C) and DTA (up to 2000 °C) |
| Vacuum Capability | High-vacuum sealed system |
| Gas Control | Integrated stainless-steel gas lines with metal-encapsulated mass flow controllers (MFCs) |
| Optional Automation | Stepper-motor-driven dual-furnace configuration and 20-position auto-sampler |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F1 |
| Temperature Range | −150 °C to 1000 °C (extendable to 2000 °C with optional furnaces) |
| Heating/Cooling Rate | 0.001–50 K/min (up to 20 K/min for Rh furnace) |
| Vacuum Capability | Down to 10⁻⁴ mbar |
| Sensor Types | DSC (Cp-optimized up to 1600 °C), DTA (up to 2000 °C with W/Re thermocouples) |
| Compliance | ASTM E793, E1269, ISO 11357, USP <1158>, GLP/GMP-ready with audit trail (Proteus® software) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F3 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | FRG Structural Adhesion Tester |
| Compliance | DIN EN 520 |
| Sample Dimensions (L × W × T) | 300 × 45 × 9.5 / 12.5 / 15.0 mm |
| Propane Purity | ≥95%, Operating Pressure: 4.0 bar |
| Device Dimensions (W × D × H) | 450 × 400 × 300 mm |
| Weight | 37 kg |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | NETZSCH GABO EPLEXOR |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –160 °C to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Static Force Range | up to 500 N (optional 1500 N) |
| Dynamic Force Range | ±25 N, ±100 N, ±150 N, or ±500 N |
| Displacement Range | 60 mm |
| Frequency Range | 0.01 Hz to 100 Hz (optional: 0.0001 Hz and 200 Hz) |
