Physical Property Testing Instruments
Filter
Showing 7081–7110 of 12460 results
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | NC-C-SC-AN Series for Bar Inspection |
| Pricing | Upon Request |
| Probe Configuration | 128-element array, max 32 elements fired per group |
| Static Sensitivity | Φ0.8 mm flat-bottom hole at depths of ½, ¼, and 1/8 bar diameter (≥5 mm min depth), SNR > 12 dB |
| Dynamic Sensitivity | Φ0.8 mm FBH at ≤0.5 m/s |
| End Blind Zone | <30 mm |
| Near-Surface Blind Zone | None |
| False Negative Rate | 0% |
| Inspection Speed | ≥60 m/min |
| Scan Modes | Linear Scan, Sector Scan, Dynamic Depth Focusing (DDF) |
| Applicable Standards | GB/T 4162, ISO 18563-1:2015, ISO 18563-2:2015, ASTM E2700 |
| Material Coverage | Carbon steel, alloy steel, bearing steel, spring steel, cold-heading steel |
| Bar Diameter Range | 16–65 mm (customizable) |
| Bar Length Range | 6–12 m |
| Surface Roughness Requirement | ≤25 µm Ra |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | NC-C-SC-AN Series for Steel Plate Inspection |
| Ultrasound Channels | 16 (expandable to 64 via cascading) |
| Probe Configuration | Up to 4 probes, 128 total elements |
| Phased Array Beamforming Capacity | 1024 delay laws |
| Data Throughput | 40 MB/s via Gigabit Ethernet |
| Network Interface | Industrial Power + Dual-Mode Fiber Optic |
| Encoder Input | 2-channel quadrature (A/B phase) |
| Trigger Mode | Internal or External (software-selectable) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| TCG (Time-Corrected Gain) | Integrated |
| Minimum Detectable Flaw | Ø3 mm flat-bottom hole (FBH) at full material thickness |
| Scanning Coverage | Adjustable multi-probe array with 15 mm overlap per 120 mm probe |
| Mechanical Architecture | Immersion-type water bath with dual staggered probe carriage assemblies |
| Compliance Standards | ISO 3183, GB/T 2970, ASTM A435, ASTM A578, ISO 10893-11 |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Model | NC-C-SCAN Series |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | NC-DMT Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | NC-MT Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Domestic (China) |
| Model | NC-Series |
| Pricing | Available Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Producer |
| Country of Origin | Domestic (China) |
| Model | NCS-MMTI600 |
| Price | USD 1 (Reference Only) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Central Iron and Steel Research Institute) |
| Type | Domestic |
| Model | NCS-SJ01 |
| Pricing | Upon Request |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (Steel Research Institute Nano-Characterization Co., Ltd.) |
| Type | Pendulum Impact Tester |
| Compliance Standards | GB/T 229, GB/T 19478–2005, ASTM E23, ISO 14556 |
| Output Data | Load-time, Force-displacement, Energy absorption, Crack initiation & propagation parameters (K₁d, J₁d) |
| Sensor Resolution | High-resolution dynamic load cell & energy transducer |
| Control Interface | Touchscreen-based digital control system |
| Test Modes | Charpy, Izod, Tensile Impact, Bending Impact |
| Report Export | Word, Excel-compatible formats |
| Frame Construction | Monolithic cast steel base and column |
| Brand | NCS |
|---|---|
| Model | YYU-5/50 |
| Gauge Length | 50 mm |
| Extension Range | ±5 mm |
| Output Signal | Analog Voltage (±10 V) or Digital RS-232/RS-485 |
| Resolution | ≤0.1 µm |
| Accuracy | ±0.5% of full scale |
| Operating Temperature | 10–40 °C |
| Compliance | ASTM E8/E21, ISO 6892-1, GB/T 228.1 |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS (National Center for Steel Research) |
| Type | Domestic |
| Model | NCS-RBET Series |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ND-11 |
| Pricing | Upon Request |
| Measurement Parameters | Reflectance Density (OD), Reflectance (%) |
| Measurement Range | 0.00–100.0% (Reflectance), 0.00–3.00 D (Optical Density) |
| Aperture Sizes | Φ3.0 mm, Φ1.7 mm, Φ1.0 mm |
| Illumination/Reception Geometry | 0° vertical illumination / 45° annular edge reception |
| Accuracy (Repeatability) | ±0.01 D (≤2.0 D, Φ3.0 mm) |
| Data Compensation Function | Yes, for cross-model result compatibility |
| Averaging Function | 2–9-point reflectance intensity averaging |
| Data Storage Capacity | Up to 500 measurements |
| Dimensions | 210 × 72 × 50 mm (L × D × H) |
| Weight | 530 g (including Ni-Cd battery) |
| Power Supply | Built-in 4.8 V / 800 mAh Ni-Cd rechargeable battery |
| Light Source | Tungsten-halogen lamp (CCT ≈ 2856 K) |
| Optional Accessories | Serial printer PR-95, RS-232 cable, PC software for Excel-compatible data export, calibration standard plates |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NDJ-1 |
| Quotation | Available Upon Request |
| Viscosity Range | 10–100,000 mPa·s |
| Rotors | Four interchangeable spindles (No. 1–4) |
| Speed Settings | 6, 12, 30, and 60 rpm |
| Accuracy | ±5% for Newtonian liquids |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, ≤80% RH |
| Dimensions (L×W×H) | 300 × 300 × 450 mm |
| Net Weight | 1.5 kg (excluding stand) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NDJ-1 |
| Price | USD 395 (FOB Shanghai) |
| Display | Analog Dial |
| Rotational Speeds | 6 / 12 / 30 / 60 rpm |
| Included Rotors | #1–#4 |
| Measuring Range (Newtonian Fluids) | 10–10⁵ mPa·s |
| Accuracy | ±5% (at specified calibration points) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NDJ-5S |
| Instrument Type | Rotational Viscometer |
| Measuring Range | 1–100,000 mPa·s |
| Spindle Speeds | 6, 12, 30, 60 rpm |
| Spindles | LV #1–#4 (optional #0 spindle available) |
| Accuracy | ±1.0% of full scale |
| Repeatability | 0.5% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Display | LCD with blue backlight |
| Features | Real-time viscosity readout, auto-range alert, programmable measurement timer, full-scale linear calibration, temperature probe interface (RTD-compatible) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | NDJ-5S |
| Pricing | Available Upon Request |
| Display | LCD with blue backlight |
| Drive System | High-resolution stepper motor |
| Power Supply | 220 V / 50 Hz AC |
| Measurement Range | 10–100,000 mPa·s (with spindles #1–#4) |
| Optional Low-Viscosity Range | 1–10 mPa·s (with #0 spindle) |
| Accuracy | ±3% of full scale (for Newtonian fluids) |
| Repeatability | ±0.5% of full scale (for Newtonian fluids) |
| Output Interface | RS232 (optional) |
| Compliance | Designed per GB/T 2794–2013 (Chinese national standard for viscometry), compatible with ISO 2555 and ASTM D2196 practices |
| Accessories | #0 spindle (optional), ultra-low-viscosity adapter, external thermostatic bath (not included) |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma EFI HiRes |
| Pricing | Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma EFI |
| Pricing | Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma SSM HiRes |
| Pricing | Available Upon Request |
| SQUID Spatial Resolution | 3 µm |
| HiRes Spatial Resolution | 250 nm |
| SQUID Scan Area | ≥100 mm × 100 mm |
| HiRes Scan Area | ≥100 mm × 100 mm |
| SQUID Current Sensitivity | 500 nA @ 333 µm, 1.5 µA @ 1000 µm |
| HiRes Current Sensitivity | 5 µA @ 2 µm, 100 µA @ 100 µm |
| SQUID Magnetic Field Sensitivity | 15 pT/√Hz (typ.) |
| HiRes Magnetic Field Sensitivity | 10 nT/√Hz (typ.) |
| SQUID Operating Frequency Range | DC–25 kHz |
| HiRes Operating Frequency Range | 10 kHz–200 kHz |
| SQUID Imaging Depth | ≤10 mm |
| HiRes Imaging Depth | <100 µm |
| Excitation Source | ±10 V @ 100 mA, DC–200 kHz |
| Optical Lens Resolution | 2 µm (NIR/Visible) |
| Power Supply | 110–120 V @ 20 A or 220–240 V @ 10 A |
| OS | Windows 10 64-bit |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma SSM |
| Pricing | Upon Request |
| Spatial Resolution (SQUID) | 3 µm |
| Scan Area (SQUID) | ≥100 mm × 100 mm |
| Current Sensitivity | 500 nA @ 333 µm |
| Magnetic Field Sensitivity | 15 pT/√Hz (typ.) |
| Imaging Depth | 10 mm |
| SQUID Operating Frequency Range | DC to 25 kHz |
| Function Generator | ±10 V @ 100 mA, DC to 200 kHz |
| Optical Lens Resolution | 2 µm (NIR/Visible) |
| Power Supply | 110–120 V @ 20 A or 220–240 V @ 10 A |
| OS | Windows 10 64-bit |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Model | N60 |
| X-ray Source Energy | 100 kV |
| Detector Type | Flat-panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 8 µm |
| Measurement Field of View | 36 mm × 60 mm |
| Sample Weight Capacity | 20 kg |
| System Dimensions | 800 mm × 310 mm × 375 mm |
| Accuracy | Micron-level |
| Software | Integrated acquisition, reconstruction, quantification & STL export |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Model | N70 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 4 µm |
| X-ray Energy | 100 kV |
| Maximum Sample Dimensions | 100 mm × 120 mm (diameter × height) |
| Max Sample Weight | 20 kg |
| System Dimensions | 1050 mm × 607 mm × 463 mm |
| Accuracy | Micron-Level |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Sample Rotation Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 mm × 163 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions | 1200 mm × 640 mm × 520 mm |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 mm × 163 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions | 1200 mm × 640 mm × 520 mm |
| Precision | Micron-Level |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Sample Rotation Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 mm × 163 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions | 1200 mm × 640 mm × 520 mm |
| Precision | Micron-Level |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Model | N80 |
| X-ray Source Energy | 110 kV |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 2 µm |
| Accuracy | Micron-Level |
| Maximum Sample Dimensions | 100 mm × 163 mm (diameter × height) |
| Maximum Sample Weight | 20 kg |
| System Footprint | 1200 mm × 640 mm × 520 mm |
| X-ray Source | Sealed-Tube Transmission Type |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Sample Rotation Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 mm × 163 mm |
| Maximum Sample Weight | 20 kg |
| Dimensions | 1200 mm × 640 mm × 520 mm |
| Precision | Micron-Level |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 2 µm |
| X-ray Energy | 110 kV |
| Field of View | 100 × 163 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions | 1200 × 640 × 520 mm |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 300 nm |
| X-ray Energy | 160 kV |
| Maximum Sample Dimensions | 100 mm × 400 mm |
| System Footprint | 1540 mm × 580 mm × 740 mm |
| Brand | Neoscan |
|---|---|
| Origin | Belgium |
| Model | N90 Desktop Nanoscale CT |
| X-ray Source | 20–160 kV, 16 W Diamond-Window Microfocus Tube |
| Detector Configuration | Dual-Detector System (27 MP CMOS + 7 MP Flat-Panel Detector) |
| Spatial Resolution | ≤300 nm (≤40 nm voxel size achievable under optimized conditions) |
| Scan Mode | Rotation-Only (RO) |
| Maximum Sample Dimensions | Ø100 mm × H400 mm |
| System Dimensions | 1540 mm × 580 mm × 740 mm |
| Weight | 550 kg |
| Radiation Shielding | Integrated Lead-Lined Enclosure Compliant with IEC 61331-1 & EN 62463 |
| Filtration | Motorized 7-Position Filter Changer |
| Software Platform | NeoScan Suite v5.2 with GLP/GMP-Aware Audit Trail & FDA 21 CFR Part 11 Compliance Options |