Empowering Scientific Discovery

Hach 2582sc Trace Dissolved Oxygen Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Hach
Origin Imported
Manufacturer Type Manufacturer
Model Hach 2582sc Trace Dissolved Oxygen Analyzer
Pricing Upon Request

Overview

The Hach 2582sc Trace Dissolved Oxygen Analyzer is a high-precision, industrial-grade online analyzer engineered for continuous measurement of ultra-low dissolved oxygen (DO) concentrations in ultrapure water systems—particularly within power generation, semiconductor manufacturing, and pharmaceutical purified water loops. It operates on the principle of galvanic or polarographic electrochemical sensing (configurable per application), utilizing a membrane-covered, temperature-compensated sensor that delivers stable, drift-free measurements down to sub-ppb levels. The system integrates seamlessly into existing plant automation architectures via standard 4–20 mA analog outputs and Modbus RTU/TCP digital communication protocols. Designed specifically for compliance-critical environments, the 2582sc meets stringent performance expectations for long-term stability, low maintenance intervals, and repeatable calibration traceability.

Key Features

  • Modular architecture combining the SC4500 universal controller with a field-proven Hach trace DO sensor—enabling flexible deployment in panel-mounted or pipe-rack configurations.
  • Intuitive 5.7-inch color touchscreen interface with multilingual support (English, Spanish, German, Chinese), consistent with Hach’s SC platform navigation logic and icon-based menu structure.
  • Identical mechanical footprint and mounting pattern as the legacy Hach 9500sc controller—reducing retrofit time and eliminating re-engineering of enclosure cutouts or conduit entries.
  • Auto-zero and span calibration routines supported via built-in solenoid valves and optional zero-gas manifold integration; calibration logs include timestamp, operator ID, and deviation metrics.
  • Rugged IP66-rated enclosure with NEMA 4X compatibility, suitable for indoor and outdoor installations in harsh utility environments including turbine halls and chemical feed rooms.
  • Integrated temperature compensation using Pt1000 RTD input—ensuring accurate DO readings across operational ranges from 0 to 50 °C.

Sample Compatibility & Compliance

The 2582sc is validated for use with deionized water, boiler feedwater, condensate, and ultrapure water (UPW) streams meeting ASTM D1125 and ISO 5667-3 requirements for sampling integrity. Sensor design minimizes flow sensitivity and eliminates oxygen ingress artifacts during low-flow or stagnant conditions. The analyzer complies with IEC 61508 (SIL2-capable architecture), EN 61326-1 (EMC for industrial environments), and supports audit-ready documentation per FDA 21 CFR Part 11 when paired with Hach’s DataStream™ software. All firmware revisions are version-controlled and qualified under Hach’s internal GLP-aligned software development lifecycle.

Software & Data Management

The SC4500 controller hosts embedded firmware supporting real-time data logging (up to 1 year at 1-minute intervals), configurable alarm thresholds with latching/non-latching behavior, and event-driven notifications via relay outputs or Modbus status registers. Optional Hach DataStream™ software enables centralized configuration management, remote diagnostics, and secure export of CSV-formatted trend reports compliant with ISO/IEC 17025 record retention guidelines. Calibration history, sensor diagnostics (e.g., membrane integrity, electrolyte level estimation), and system uptime statistics are stored locally and retrievable via USB or Ethernet.

Applications

  • Monitoring dissolved oxygen in high-pressure boiler feedwater circuits to prevent oxidative corrosion of economizers and superheater tubes.
  • Continuous verification of deaerator performance and post-treatment polishing stages in thermal power plants.
  • Real-time DO surveillance in semiconductor fab UPW distribution networks where oxygen excursions >1 ppb may induce wafer surface defects.
  • Validation and routine monitoring of water-for-injection (WFI) and purified water systems under EU GMP Annex 1 and USP guidance.
  • Integration into distributed control systems (DCS) or PLC-based water treatment skids for closed-loop chemical dosing control (e.g., hydrazine or carbohydrazide injection).

FAQ

What is the typical detection range for the 2582sc analyzer?

The instrument measures dissolved oxygen from 0.1 ppb to 200 ppb in ultrapure water applications, with extended range capability up to 1,000 ppb when configured for less demanding service conditions.
Is sensor replacement a field-serviceable operation?

Yes—the trace DO sensor uses a standardized bayonet mount and pre-calibrated module design; replacement requires no tooling and can be completed in under five minutes without recalibration if using factory-trimmed sensors.
Does the 2582sc support regulatory audit trails?

When operated with DataStream™ software and enabled audit settings, it records user actions, parameter changes, calibration events, and system faults with immutable timestamps and operator authentication—fully aligned with 21 CFR Part 11 electronic record requirements.
Can the analyzer operate in high-conductivity condensate streams?

It is rated for conductivity up to 10 µS/cm; for higher conductivity samples, optional flow-cell conditioning or dilution modules are recommended to maintain measurement fidelity and sensor longevity.
What certifications does the SC4500 controller hold?

The controller carries CE marking, UL 61010-1 listing, ATEX II 2G Ex db IIB T4 Gb certification for hazardous area Zone 1 installations, and RoHS 2011/65/EU compliance.