Empowering Scientific Discovery

PMM 9060 6 GHz RF Receiver Frequency Extension Module

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PMM
Origin Italy
Model PMM 9060
Frequency Range 30 MHz – 6 GHz
Frequency Resolution 0.1 Hz
Measurement Accuracy < 2 ppm
Input Impedance 50 Ω, N-type female
VSWR < 1.2 @ 0 dB attenuation, < 2.0 @ full attenuation
Attenuation Range 0–55 dB (5 dB steps)
Pre-amplifier Gain 10 dB
Max. Input Level (non-damaging) 137 dBµV (1 W sine), 97 dBµV/MHz (pulse spectral density)
Preselector Low-pass + six band-pass filters covering 30 MHz–1000 MHz and >1000 MHz
IF Bandwidths (3 dB) 3, 10, 30, 100, 300 kHz, 1 MHz
IF Bandwidths (6 dB) 120 kHz (CISPR 16-compliant)
Noise Floor < 2 dBµV (QP, 200 Hz BW, 9–150 kHz), < −2 dBµV (AV, same BW)
Detectors Peak, Quasi-Peak, Average, RMS, Smart Detector
Parallel Detection Supported for Peak, QP, RMS, AV
Sweep Time 1 ms – 30 s (CISPR 16 default)
Display Units dBm, dBµV
SNR > 20 dB
Amplitude Probability Distribution (APD) Capability Yes
Tracking Generator Output 10 Hz – 30 MHz, AM demodulation via PMM 9010
Interface High-speed optical fiber (≥2.5 Gb/s), RS-232 (service only)
Power Supply 10–15 VDC, 2.5 A
Operating Temperature 0 °C – 40 °C
Dimensions 235 × 105 × 105 mm
Weight 2.0 kg

Overview

The PMM 9060 is a high-performance RF frequency extension module engineered to extend the operational bandwidth of the PMM 9010 digital EMI receiver from its native upper limit to 6 GHz. Designed in accordance with CISPR 16-1-1 and IEC 61000-4-3 requirements, the module functions as a digitally optimized front-end that performs analog-to-digital conversion directly at the antenna feed point—eliminating traditional coaxial cable limitations such as insertion loss, impedance mismatch, and ambient RF pickup. By integrating a low-noise preamplifier, precision preselector filtering (including one low-pass and six band-pass filters), and ultra-stable local oscillator architecture, the 9060 ensures signal fidelity across the full 30 MHz–6 GHz range while maintaining traceable measurement uncertainty below ±2 ppm. Its optical fiber interface enables galvanically isolated, high-bandwidth (≥2.5 Gb/s), deterministic data transfer to the PMM 9010 main unit—preserving amplitude integrity and phase coherence critical for compliant radiated emissions testing.

Key Features

  • Optical fiber-coupled architecture ensures complete electromagnetic isolation between antenna and receiver—removing common-mode noise and cable-induced measurement artifacts.
  • Integrated 10 dB low-noise preamplifier and programmable 0–55 dB attenuation (5 dB steps) enable dynamic range optimization across diverse emission levels.
  • CISPR 16-1-1 compliant IF bandwidths: 3, 10, 30, 100, 300 kHz, and 1 MHz (3 dB), plus standardized 120 kHz (6 dB) for quasi-peak detection.
  • Real-time parallel detection supporting simultaneous Peak, Quasi-Peak, Average, and RMS measurements per frequency step—reducing total test time without compromising compliance validity.
  • Amplitude Probability Distribution (APD) functionality implemented in hardware and firmware, enabling statistical analysis of broadband and pulsed emissions above 1 GHz per emerging standards such as CISPR 32 Ed. 3 and MIL-STD-461G.
  • Compact, lightweight enclosure (235 × 105 × 105 mm, 2.0 kg) allows direct mounting behind antennas—including biconical, log-periodic, and horn types—minimizing feedline length and associated uncertainties.
  • Rechargeable, hot-swappable Li-ion battery (4 h continuous operation) provides full galvanic isolation from AC mains, eliminating ground loops and ensuring stable baseline performance in field and semi-anechoic environments.

Sample Compatibility & Compliance

The PMM 9060 is fully compatible with all standard EMI antennas used in radiated emissions testing—including 30 MHz–1 GHz biconical and log-periodic antennas, and 1–6 GHz double-ridged guide horns—when paired with appropriate mounting adapters. It meets essential regulatory and metrological requirements for accredited EMC laboratories, including ISO/IEC 17025:2017 clause 5.8 (equipment validation), CISPR 16-1-1:2023 Annex D (preselector verification), and ANSI C63.4-2022 Section 6.3 (receiver calibration traceability). Its design supports both commercial (EN 55032, FCC Part 15) and military (MIL-STD-461G RE102) test protocols. The module’s internal preselector filters are validated per CISPR 16-1-1 Table 5, and its noise floor performance is certified against CISPR 16-2-3 limits for auxiliary equipment contribution.

Software & Data Management

Controlled exclusively through PMM EMI Suite v6.x or later, the 9060 integrates seamlessly into automated test sequences compliant with EN 55016-2-3, CISPR 32, and MIL-STD-461G. The software supports three operational modes: fully automatic (predefined standard templates), semi-automatic (user-guided sweep with adaptive dwell time), and manual (real-time spectrum observation with marker-based peak logging). All measurement data—including raw IQ samples, APD histograms, and detector-specific time-domain traces—are stored in vendor-neutral .csv and .s2p formats, with optional XML metadata embedding for GLP/GMP audit trails. Firmware updates and configuration backups are performed over the optical link; RS-232 remains reserved solely for factory-level diagnostics and calibration verification. Full 21 CFR Part 11 compliance is achievable when deployed with PMM’s optional audit-log and electronic signature modules.

Applications

  • Radiated emissions testing of wireless devices (Wi-Fi 6E/7, UWB, 5G NR FR1/FR2, Bluetooth LE Audio) up to 6 GHz in accordance with CISPR 32 and EN 301 489.
  • Pre-compliance and certification-grade immunity assessment using the integrated tracking generator for antenna factor validation and site attenuation verification.
  • Pulsed EMI characterization in automotive radar (77–81 GHz frontend harmonics), industrial IoT gateways, and medical telemetry systems requiring APD-based statistical evaluation.
  • Field diagnostics of RFI sources in complex electromagnetic environments—such as broadcast sites, smart grid substations, and aerospace ground support infrastructure—where coaxial cable artifacts would otherwise obscure root-cause signals.
  • Calibration laboratory use as a transfer standard for 30 MHz–6 GHz EMI receiver verification, supported by NIST-traceable calibration certificates issued by PMM-accredited service centers.

FAQ

Can the PMM 9060 operate independently without the PMM 9010?
No. The 9060 is a dedicated front-end extension module and lacks internal signal processing, display, or storage capabilities. It must be optically coupled to a PMM 9010 main unit for digitization, demodulation, and result generation.
Is the 9060 compatible with third-party EMI receivers?
No. Its optical interface, timing synchronization protocol, and data encoding scheme are proprietary to the PMM 9010 platform. Interfacing with non-PMM systems is not supported.
Does the module support real-time spectrum analysis beyond CISPR bandwidths?
Yes. In spectrum analyzer mode, the 9060 delivers real-time FFT sweeps with user-selectable RBW from 10 Hz to 1 MHz and span up to 100 MHz—though CISPR-compliant measurements require strict adherence to defined IF bandwidths and detector weighting.
How is calibration maintained across temperature variations?
The module incorporates temperature-compensated crystal oscillators (TCXO) and on-board reference signal monitoring. Daily system verification per CISPR 16-1-1 Clause 8.3 is recommended before formal testing.
Can the battery be replaced in the field without tools?
Yes. The battery compartment features a thumb-screw latch; replacement requires no tools and takes less than 10 seconds. Fully charged spares are available as PMM accessory part #BAT-9060-RC.