Purification Equipment
Filter
Showing 481–510 of 1230 results
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Model | HPE-66B |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Capacity per Position | 1 mL (compatible with 50–200 mL tubes) |
| Rotational Radius | 5 mm |
| Speed Range | 0–600 rpm |
| Heating Method | PTC Water Bath with Lid Heating |
| Vacuum Control Range | Adjustable down to ≤5 mbar (display resolution: 1 mbar |
| manual control precision | 10 mbar) |
| Gradient Programs | Up to 5 segments, 30 pre-stored methods |
| Max Total Program Duration | 42.5 hours |
| Display | 5-inch capacitive touchscreen with real-time pressure/temperature curve logging |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity per Position | 200 mL |
| Vacuum System | HVS-03 Integrated Controller (PTFE-lined pump head, diaphragm, and valves) |
| Ultimate Vacuum | 20 mbar |
| Adjustable Vacuum Range | 20–1000 mbar |
| Vacuum Control Resolution | 1 mbar (display), ±5 mbar (control accuracy) |
| Gradient Stages | Up to 5 programmable segments |
| Max Program Duration | 42.5 h |
| Pump Flow Rate | 50 L/min |
| Vacuum Port Diameter | 8 mm |
| Motor Power Rating | 100 W |
| Collection Flask Options | 1000 mL or 2000 mL |
| Cooling System | Integrated recirculating chiller unit |
| Control Interface | 5-inch capacitive touchscreen with real-time pressure curve logging |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Maximum Sample Capacity | 200 mL per tube |
| Throughput Options | 9 × 850 mL |
| Evaporation Environment | Transparent Glass Water Bath |
| Quantitative Endpoint Detection | 1 mL or 0.5 mL preset volume |
| Optional Accessory | Sealed Lid Assembly |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HSC-12A |
| Heating Method | Water Bath |
| Temperature Range | 0–100 °C |
| Temperature Stability | ±1 °C |
| Sample Capacity | 12 or 24 positions |
| Adjustable Tube Holder Diameter | Yes |
| Gas Flow Rate | 0–5 L/min |
| Heating Power | 150 W |
| Weight | 4.5 kg |
| Control | 4-digit LED display with PID temperature regulation, overheat protection, PTC heating element |
| Power Supply | 220 V, 50 Hz |
| Gas Inlet Pressure | 0–200 kPa |
| Materials in Contact with Solvents | 316 stainless steel, anodized aluminum, plastic-coated surfaces |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±1 °C |
| Sample Capacity | 12 or 24 positions |
| Tube Diameter Compatibility | 10–25 mm |
| Nitrogen Flow Rate | 0–5 L/min |
| Rated Power | 400 W |
| Dimensions (HSC-12B) | Ø250 × 820 mm |
| Weight | 7 kg |
| Control | 4-digit LED display with PID temperature regulation, overheat protection, PTC heating element |
| Power Supply | 220 V, 50 Hz |
| Gas Inlet Pressure | 0–200 kPa |
| Material Contacting Solvents | 316 stainless steel, anodized aluminum, or epoxy-coated surfaces |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Model | HSC-24A |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±1 °C |
| Sample Capacity | 24 positions |
| Tube Diameter Compatibility | 10–29 mm |
| Nitrogen Flow Rate | 0–10 L/min |
| Heating Power | 150 W |
| Power Supply | 220 V, 50 Hz |
| Control System | 4-digit LED display with PID temperature regulation and overheat protection |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HSC-24BA |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±1 °C |
| Sample Capacity | 24 positions |
| Tube Diameter Compatibility | 11–21 mm |
| Nitrogen Flow Rate | 0–10 L/min |
| Heating Power | 1000 W |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-ZLA |
| Heating Method | Far-Infrared Electric Heating Mantle (Flame-Free) |
| Cooling Method | External Chilled Water Circulator (Recommended) or Tap Water (Not Recommended Due to Scaling Risk) |
| Distillation Rate | 0–6 mL/min |
| Heating Ramp Time | <20 min |
| Independent Heating Zones | 6 |
| [Brand | HePu (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | R-1005 |
| Capacity | 5 L |
| Voltage/Frequency | 220 V / 50 Hz |
| Total Power | 2100 W |
| Rotation Speed | 0–120 rpm |
| Heating Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 °C |
| Vacuum Degree | ≤0.095 MPa |
| Condenser Surface Area | 0.5 m² |
| Bath Lift Stroke | 140 mm |
| Dimensions (W×D×H) | 980 × 480 × 1260 mm |
| Net Weight | 46 kg] |
| [Brand | HePu (Jihepu) |
|---|---|
| Origin | Shandong, China |
| Model | R-1020 |
| Capacity | 20 L |
| Ultimate Vacuum | 399.9 Pa (≤3 mmHg) |
| Rotation Speed | 10–130 rpm |
| Bath Temperature Range | Ambient to 99 °C |
| Heating Control Accuracy | ±1 °C (typical for digital PID-controlled stainless steel water bath) |
| Condenser Surface Area | Equivalent to high-efficiency triple-loop vertical glass condenser |
| Motor | 250 W DC motor |
| Power Supply | 1×220 V / 50 Hz or 3×380 V / 50 Hz |
| Total Power Consumption | 4 kW |
| Dimensions (L×W×H) | 1250 × 600 × 2100 mm |
| Lift Stroke | 0–190 mm |
| Sealing | Dual-material seal (PTFE + fluororubber) |
| Material Contact | High-borosilicate glass (DIN ISO 3585) and PTFE throughout wetted path] |
| Brand | HePu |
|---|---|
| Origin | Shandong, China |
| Model | RE-5003 |
| Rotating Flask Capacity | 50 L |
| Collection Flask Capacity | 20 L |
| Ultimate Vacuum | 0.098 MPa |
| Rotation Speed Range | 0–110 rpm (frequency-controlled, digital display) |
| Bath Temperature Range | 0–400 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 8 kW (380 V / 50 Hz) |
| Rotation Motor Power | 180 W (220 V / 50 Hz) |
| Condenser Type | Vertical triple-coil glass condenser (main coil: Ø160 × 840 mm |
| auxiliary coil | Ø160 × 530 mm) |
| Cooling Surface Area | 0.11 m² |
| Overall Dimensions (W×D×H) | 1520 × 620 × 2470 mm |
| Net Weight | 170 kg |
| Brand | Hercy |
|---|---|
| Origin | Hunan, China |
| Model | ZLS-2 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 60 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 6 × 50 mL |
| Rotational Speed | 1500 rpm |
| Vacuum Interface | φ10 mm |
| Final Vacuum Level | 0.1 mbar |
| Dimensions (L×W×H) | 500 × 490 × 280 mm |
| Timer Range | 1 min – 99 h 59 min |
| Rotor Configurations | 62 × 1.5 mL |
| Over-Temperature Protection | 98 °C |
| Heating Method | Uniform Chamber Heating |
| Chamber Material | Anodized Aluminum Alloy |
| Lid Material | Polymethyl Methacrylate (PMMA) Transparent Cover |
| Drive System | Brushless DC Motor with Contactless Drive |
| Control Interface | TFT-LCD True Color Display with Dual Touch + Physical Keypad |
| Optional Accessories | CT-6 Cold Trap, External Vacuum Pump |
| Brand | Hershey |
|---|---|
| Model | CT-6 |
| Type | Cryogenic Cold Trap (Cryo-Cold Trap) |
| Cooling Temperature Range | Ambient to –40 °C |
| Temperature Control Accuracy | ±1 °C |
| Cold Trap Capacity | 4 L |
| Condensate Collection Volume | 200 mL |
| Refrigeration Power | 300 W |
| Refrigerant | R404a |
| Vacuum Port Diameter | φ10 mm |
| Timer Range | 1 min – 99 h 59 min |
| Net Weight | 44 kg |
| Dimensions (L×W×H) | 440 × 340 × 630 mm |
| Display | 4.3″ TFT True-Color Touchscreen with Dual Control Interface |
| Cooling System | Hermetically Sealed, Eco-Friendly Refrigeration Unit |
| Circulation Type | Closed-Loop Internal Circulation |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments and compatible with GLP/GMP workflows requiring traceable condensate capture and vacuum integrity |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | ZLS-4 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to +60 °C (optional heating) |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Capacity | 6 × 250 mL |
| Rotational Speed | 1500–2000 rpm |
| Vacuum Interface | φ12 mm |
| Power Supply | AC 220 V / 50 Hz |
| Max. Power Consumption | 1.5 kW |
| Noise Level | <50 dB(A) |
| Chamber Material | Anodized Aluminum Alloy |
| Display | TFT-LCD Touchscreen with Dual Keypad Interface |
| Drive System | Brushless DC Motor with Contactless Magnetic Drive |
| Cold Trap Options | CT40 or CT50 |
| Compatible Vacuum Pumps | Diaphragm Pump, Domestic Oil-Sealed Pump, or Imported Oil-Sealed Pump |
| Rotor Configurations | 2×96-well, 62×1.5 mL, 12×10 mL, 6×50 mL, 6×250 mL, or 6×2×50 mL |
| Optional Adapters | 6×5×20 mL |
| Brand | Herxi |
|---|---|
| Model | ZLS-1 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 60 °C |
| Temperature Control Accuracy | ±1 °C |
| Rotor Capacity | 62 × 1.5 mL tubes |
| Maximum Rotational Speed | 1500 rpm |
| Timer Range | 0–99 h 59 min |
| Chamber Material | Anodized Aluminum with Corrosion-Resistant Coating |
| Drive System | Maintenance-Free Electromagnetic Drive |
| Display | 4.3″ TFT True-Color Touchscreen Interface |
| Dimensions (W×D×H) | 500 × 490 × 280 mm |
| Compatibility | Optional Cold Trap and Vacuum Pump (not included) |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZLS-3 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 60 °C (heating optional) |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 6 × 250 mL |
| Maximum Rotational Speed | 2000 rpm |
| Maximum RCF | 500 × g |
| Vacuum Interface | φ10 mm |
| Ultimate Vacuum | 0.1 mbar (with compatible pump) |
| Timer Range | 1 min – 99 h 59 min |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Power Supply | AC 220 V / 50 Hz |
| Optional Accessories | CT-6 Cold Trap, 2×2×48-well Microplate Rotor, 50 mL & 20 mL Adapters |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W20 Series (L-11 / T-21 / S-41) |
| Instrument Type | Automated Quantitative Concentration & Ashing System |
| Temperature Range | 0–300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Evaporation Capacity | 4 × 24,000 mL (total, configurable per channel) |
| Microwave Frequency | 2450 MHz |
| Evaporation Power | 800–3200 W (model-dependent) |
| Ashing Power | 800 W |
| Evaporation Cavity Volume | 24 L per channel |
| Ashing Cavity Volume | 1.8 L |
| Microwave Leakage | <5 mW/cm² (per GB 4706.21 & GB 5959.6) |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W20 Series (Dual-Channel HXN-W20Y-20 / Quad-Channel HXN-W20W-40) |
| Instrument Type | Automated Quantitative Microwave Concentrator |
| Temperature Range | 0–300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Total Sample Capacity | 4 × 24 L (Quad-Channel Configuration) |
| Microwave Power/Frequency | 1600 W / 2450 MHz (Dual) or 3200 W / 2450 MHz (Quad) |
| Cavity Material | Stainless Steel with PTFE Coating (Evaporation Mode) or Quartz Lining (Ashing Mode) |
| Evaporating Dish Standard | 4 × 2.9 L (Customizable up to 10 L) |
| Cooling/Exhaust | Low-Noise (<60 dB) Corrosion-Resistant Centrifugal Fan |
| Safety Compliance | GB 4706.21–2008, GB 5959.6–2008, Microwave Leakage <5 mW/cm² |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W20 Series |
| Instrument Type | Automated Quantitative Microwave Evaporator |
| Temperature Range | 0–300 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume Capacity | 24,000 mL |
| Microwave Power | 0–800 W (HXN-W20/W20D) / 0–4000 W (HXN-W20P) |
| Frequency | 2450 MHz |
| Cavity Volume | 24 L (W20/W20D) / 91 L (W20P) |
| Evaporating Dish Standard | 2.9 L (customizable up to 10 L) |
| Surface Area | 0.1 m² (standard) / 0.25 m² (W20P) |
| Microwave Leakage | <5 mW/cm² (per GB 4706.21 & IEC 60335-2-90) |
| Control System | PLC-based with programmable multi-step protocols |
| Display | Color touchscreen (W20D/W20P) or keypad + rotary interface (W20) |
| Noise Level | ≤60 dB(A) |
| Dimensions (W×D×H) | 760×550×610 mm (W20), 760×550×710 mm (W20D), 850×880×650 mm (W20P) |
| Construction | Fully welded stainless steel cavity with PTFE-coated interior |
| Safety | Interlocked door, explosion-resistant design, integrated LED illumination, transparent observation window |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W40S |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 0–300°C |
| Temperature Control Accuracy | ±0.1°C |
| Maximum Sample Volume Capacity | 40 L |
| Microwave Power | 0–800 W at 2450 MHz |
| Electric Heating Power | 1600 W |
| Cavity Volume | 40 L |
| Construction | Stainless Steel Monolithic Welded Body with PTFE Anti-Corrosion Coating |
| Evaporation Vessels | One 2000 mL Ceramic Tray (microwave mode) or Two 2000 mL Standard Glass Beakers (electric heating mode) |
| Acid Removal & Ashing Capacity | Three 100 mL Ceramic Crucibles |
| Temperature Monitoring | Dual-mode — Non-contact Infrared + Thermocouple |
| Exhaust System | Corrosion-Resistant Centrifugal Fan (≤60 dB) |
| Control System | PLC-based Intelligent Touchscreen Interface with LED Internal Illumination and Transparent Observation Window |
| Dimensions (W×D×H) | 760 × 550 × 610 mm |
| Brand | HEXING BIOCHEMICAL |
|---|---|
| Origin | Shandong, China |
| Model | HXN-W50 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Cycle | 5 L |
| Total Throughput Capacity | 50–100 L (automated sequential concentration) |
| Microwave Output Power | 3200 W |
| Temperature Sensor | Thermocouple (±1 °C accuracy) |
| Evaporation Vessel | 5 L microwave-compatible ceramic-coated stainless steel dish |
| Cavity Material | Stainless steel with multi-layer PTFE coating |
| Exhaust System | Corrosion-resistant variable-frequency centrifugal blower (2.5 m³/min airflow) |
| Control System | PID controller or optional PLC-based touchscreen interface |
| Safety Interlock | Door-activated power cutoff with multi-layer RF leakage suppression |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HGC-12D |
| Price | USD 650 (FOB Shanghai) |
| Sample Capacity | 12 positions |
| Heating Block Quantity | 1 |
| Dimensions (W×D×H) | 226 × 355 × 85 mm |
| Gas Flow Range | 0–5 L/min |
| Power Consumption | 150 W |
| Net Weight | 3.0 kg |
| Temperature Range | Ambient to 150 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Control | 4-digit LED display, PID algorithm, overheat protection, PTC heating element |
| Input Power | 220 V AC, 50 Hz |
| Gas Supply Pressure | 0–200 kPa |
| Construction Materials | 316 stainless steel gas manifolds and needle guides, anodized aluminum heating block, plastic-coated housing |
| Brand | HHitech |
|---|---|
| Origin | United Kingdom |
| Model | Basic-RO15(IT)/Basic-RO30(IT)/Basic-RO45(IT)/Basic-Q15(IT)/Basic-Q30(IT)/Basic-Q45 |
| Purified Water Output | 15/30/45 L/hour |
| RO Rejection Rate | 97–99% (ions), >99% (organics, MW >200 Da), >99% (particles & bacteria) |
| DI Resistivity | 13–17.5 MΩ·cm @ 25°C |
| Conductivity | 0.077–0.057 µS/cm |
| Bacterial Count | <0.01 CFU/mL (with optional 0.45 + 0.1 µm PES final filter) |
| Particle Count (>0.1 µm) | <1/mL (with optional filter) |
| Feed Water | Municipal tap water, 5–45 °C, 1.0–4.0 kgf/cm² |
| Dimensions (Standard) | 340 × 320 × 470 mm |
| Weight | ~15 kg |
| Dimensions (IT Series) | 535 × 320 × 470 mm |
| Weight | ~20 kg |
| Electrical | 100–240 V, 50/60 Hz |
| Power Consumption | 48 W / 72 W / 120 W |
| Configuration | Main unit (incl. one set of purification cartridges) + integrated 12 L pressurized tank (IT models) + accessory kit |
| Certifications | NSF-certified tubing and fittings |
| RO Membrane | Original Dow Filmtec™ elements |
| Brand | HHitech |
|---|---|
| Origin | Shanghai, China |
| Model | Benchmark |
| Pure Water Output | 60 L/hour |
| Max Flow Rate | 2.0 L/min (1.0 L/min continuous) |
| DI Water Resistivity | 16–18 MΩ·cm |
| UP Water Resistivity | 18.2 MΩ·cm @ 25°C |
| Bacterial Count | <0.01 CFU/mL |
| Particles (>0.2 µm) | <1/mL |
| TOC | <10 ppb (UP), <3 ppb (with UV 185/254 nm) |
| Endotoxin | <0.001 EU/mL (with UF membrane) |
| RNase | <1 pg/mL |
| DNase | <5 pg/mL |
| Dimensions (L×W×H) | 500 × 385 × 650 mm |
| Weight | ~25 kg |
| Power Supply | 100–240 V, 50/60 Hz, 192 W |
| Feed Water | Municipal tap water (5–35°C, 1.0–4.0 bar) |
| Brand | HHitech |
|---|---|
| Origin | Shanghai, China |
| Model | Center Series |
| Pure Water Output | 45/60/90 L/hour |
| Ultra-Pure Water Output | Up to 2.0 L/min (with full reservoir) |
| Resistivity (25°C) | ≥18.2 MΩ·cm |
| TOC | <3–10 ppb |
| Bacteria | <0.01 CFU/mL |
| Particles (>0.2 µm) | <1/mL |
| Endotoxins | <0.001 EU/mL (FC/FV models) |
| RNases | <1 pg/mL (FV models) |
| DNases | <5 pg/mL (FV models) |
| RO Feed Water Conductivity Reduction | ~95% (1st stage) |
| Dimensions (L×W×H) | 610×585×1580 mm |
| Weight | ~70 kg |
| Power | 220 V, 50 Hz, 480 W |
| Pre-treatment | DOW RO membrane |
| Final Polishing | Nuclear-grade ion exchange resin, dual-wavelength UV (254 & 185 nm), 5 kDa UF, 0.2 µm PES final filter |
| Compliance | ASTM D1193 Type I, NCCLS, CAP, GLP-aligned data logging (1 year), NSF-certified fluid path components |
| Brand | HHitech |
|---|---|
| Model | Dura Elit |
| Origin | Shanghai, China |
| Category | Laboratory Ultra-Pure Water Purification System |
| Pure Water Grade | Type I (ASTM D1193-20) |
| RO Output | 10 L/h |
| UP Output | up to 2.0 L/min (with tank) |
| Resistivity (UP) | 18.2 MΩ·cm @ 25°C |
| TOC (UP) | <3–10 ppb (configurable by model) |
| Endotoxin | <0.001 EU/mL |
| Bacteria | <0.01 CFU/mL |
| Particles (>0.1 µm) | <1/mL |
| RNase/DNase | <1 pg/mL / <5 pg/mL |
| UV Wavelengths | 254 nm & 185 nm |
| UF MWCO | 5000 Da |
| Final Filtration | Dual-layer PES membrane (0.45 + 0.1 µm) |
| Feed Water | Municipal tap water (5–45°C, 1.0–4.0 kgf/cm²) |
| Dimensions (W×D×H) | 545 × 470 × 649 mm |
| Weight | ~35 kg |
| Power | 220–240 V, 50/60 Hz, 240 W |
| Brand | HHitech |
|---|---|
| Origin | Shanghai, China |
| Model | Dura S12 |
| Pure Water Grade | Type III (ASTM D1193) |
| Resistivity | 18.2 MΩ·cm @ 25 °C (UP water) |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <10 ppb |
| Particles (>0.1 µm) | <1 particle/mL |
| Output Flow Rate | 12 L/h |
| RO Conductivity | 1–5 µS/cm |
| Organic Removal (MW >200 Da) | >99% |
| Bacterial Retention | >99% |
| Terminal Filter | (0.45 + 0.2) µm PES membrane |
| Power | 100–240 V, 50/60 Hz, 240 W |
| Dimensions (W×D×H) | 54 × 47 × 61 cm |
| Weight | ~38 kg |
| Brand | HHitech |
|---|---|
| Origin | Shanghai, China |
| Model | Dura Series Ultra-Pure Water System |
| Output Flow Rate | Up to 2.0 L/min |
| UP Water Resistivity (25 °C) | 18.2 MΩ·cm |
| TOC | <10 ppb (Standard/Low-Organic Models), <3 ppb (Ultra-Low-Organic Models) |
| Bacteria | <0.01 CFU/mL |
| Particles (>0.1 µm) | <1/mL |
| Endotoxins | <0.001 EU/mL (Heat-Resistant & Ultra-Low-Organic Models) |
| RNase | <1 pg/mL (Heat-Resistant & Ultra-Low-Organic Models) |
| DNase | <5 pg/mL (Heat-Resistant & Ultra-Low-Organic Models) |
| DI Water Resistivity | >16 MΩ·cm |
| Feed Water | Distilled, deionized or RO water |
| Temp | 5–45 °C |
| Pressure | 1 atm |
| Dimensions (L×W×H) | 545 × 470 × 610 mm |
| Weight | ~25 kg |
| Electrical | 200–240 V, 50/60 Hz |
| Power Consumption | 240 W |
| Certifications | NSF-certified tubing & fittings |
| UV Lamps | Dual-wavelength (185 nm & 254 nm), medical-grade 316L stainless steel chamber |
| Final Filter | Double-layer PES membrane, (0.45 + 0.1) µm |
| RO Membrane | Imported Dow Filmtec™ elements, lab-optimized dual-stage configuration |
| Data Interface | RS232 & USB for real-time logging of temperature and three-point conductivity/resistivity monitoring |
| Brand | HHitech |
|---|---|
| Origin | Shanghai, China |
| Model | Eco-Q |
| Pure Water Output | 15 L/h or 30 L/h |
| DI Water Output | Up to 2.0 L/min (with pressurized tank) |
| Resistivity | 16–18.2 MΩ·cm (at 25°C) |
| Heavy Metals | <0.1 ppb |
| Bacterial Count | <0.01 CFU/mL |
| Particles (>0.1 µm) | <1/mL |
| RO Salt Rejection | 97–99% (with new membrane) |
| Organic Removal | >99% for MW >200 Da |
| Feed Water | Municipal tap water, 5–45°C, 1.0–4.0 kgf/cm² |
| Dimensions (L×W×H) | 340×500×560 mm |
| Weight | ~22 kg |
| Electrical | 220 V, 50 Hz, 72 W |
| Integrated Tank | 12 L pressurized stainless-steel-free polymer tank |
| Brand | HHitech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Eco-S |
| Pricing | Available Upon Request |
| Pure Water Output | 15 / 30 L/hour |
| Ultra-Pure Water Output | Up to 2.0 L/min (with pressurized tank) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals | < 0.01 ppb |
| TOC | <10 ppb (Standard), <3 ppb (UV-equipped models) |
| Bacteria | <0.01 CFU/mL |
| Endotoxins | <0.001 EU/mL (UV + UF models) |
| Particles (>0.1 µm) | <1/mL |
| RNases | <1 pg/mL (UV + UF models) |
| DNases | <5 pg/mL (UV + UF models) |
| RO Salt Rejection | 97–99% (new membrane) |
| RO Organic Rejection | >99% (MW > 200 Da) |
| RO Microbial/Particulate Rejection | >99% |
| Feed Water | Municipal tap water, 5–45°C, 1.0–4.0 kgf/cm² |
| Dimensions (L×W×H) | 340 × 500 × 560 mm |
| Weight | ~25 kg |
| Electrical | 220 V, 50 Hz |
| Power Consumption | 72 W |
| Terminal Filtration | 0.45 + 0.1 µm PES Membrane |
