Purification Equipment
Filter
Showing 391–420 of 1250 results
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-1000 |
| Flow Rate Range | 0–10 mL/min |
| UV Detection Wavelength | 254 nm |
| Column Dimensions | 25 × 400 mm |
| Packing Material | Bio-Beads S-X3, 200–400 mesh |
| Solvent System | Ethyl Acetate–Cyclohexane (1:1 v/v) |
| Standard Loop Volume | 5 mL |
| Pump Type | Precision Plunger Pump |
| Detector Type | Single-Wavelength UV Detector |
| Sample Introduction | Manual Injection Valve with Solvent Recovery Three-Way Valve |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528, S-19, S35L00.00-34 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-2000 |
| Flow Rate Range | 0–10 mL/min |
| Maximum Pressure | Not Specified |
| Flow Stability | High (Dual-Piston Pump Architecture) |
| UV Detector Wavelength Range | 190–800 nm |
| GPC Column | 20 × 300 mm, Bio-Beads S-X3 (200–400 mesh), Eluent: Ethyl Acetate/Cyclohexane (3:7 v/v) |
| Fraction Collector | Standard 160-position rack for 20 mL tubes |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-3000 |
| Flow Rate | 0–10 mL/min |
| Max Pressure | 1 psi |
| Flow Stability | ±0.5% RSD |
| Auto-sampler Volume | 5 mL (standard loop, customizable) |
| Auto-sampler Capacity | 160 × 20 mL tubes (standard) |
| UV Detection Range | 190–800 nm |
| Column Dimensions | 20 × 300 mm |
| Packing Material | Bio-Beads S-X3 (200–400 mesh) |
| Solvent System | Ethyl Acetate/Cyclohexane (3:7 v/v) |
| Fraction Collector Options | 20 mL (160-position), 80 mL (40-position), 150 mL (12-position), 250–300 mL (8-position) |
| Solvent Recovery Valve | Integrated three-way valve for solvent recycling |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | EZ-2 4.0 Bionic |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 30 °C to 80 °C |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | EZ-2 4.0 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 30–80 °C (±1 °C control accuracy) |
| Sample Volume Capacity | 1.5 mL to 500 mL |
| Maximum Rotor Load per Position | 1.5 kg |
| Centrifugal Force | Up to 500 × g |
| Solvent Boiling Point Limit | Up to 220 °C |
| Condenser Capacity | Unlimited (auto-drain enabled) |
| Refrigerant | Low-GWP hydrofluoroolefin (HFO) blend |
| Vacuum Source | Integrated scroll pump |
| Inert Gas Purge | IGP-compatible (N₂ or Ar) |
| Acid Resistance | HCl, HNO₃ compatible |
| Solvent Compatibility | Ethanol, DCM, EtOAc, ACN, H₂O, TFA, DMF, DMSO, ether, and others |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | HT-3i |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 60 °C |
| Temperature Control Accuracy | ±1 °C within 50 °C |
| Sample Capacity | 0.2 mL to 6 L |
| Condenser | Integrated |
| User Interface | Touchscreen Control Software |
| Safety Features | Anti-bumping (Dri-Pure™), Auto-shutdown, HCl-resistant Construction, Inert Gas Purge Capability |
| Advanced Modes | LyoSpeed™ Fast Freeze-Drying, EXALT™ Controlled Crystallization |
| Design | Front-access Door, Multi-layer Rotor Architecture, Compact Footprint |
| Compatibility | Full Interchangeability with Genevac HT-Series Sample Holders |
| Automation Integration | Lab-automation Ready (e.g., robotic arm interface support) |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | DNA |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient, 30–80 °C (adjustable in 1 °C increments) |
| Vacuum Level | 10 mbar |
| Rotational Speed | 1465 rpm |
| Dimensions (W×D×H) | 360 × 597 × 300 mm |
| Weight | 34 kg |
| Rotor Configurations | 48 × 1.5 mL tubes, 12 × 15 mL tubes, 8 × 50 mL tubes, 96-well microplates |
| Cold Trap | Not included |
| Pressure Controller | Not included |
| Operating Modes | Water, Alcohol, Other Solvents |
| Sample Compatibility | Tubes, microcentrifuge tubes, vials, round-bottom flasks, 96-well plates |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | DUO |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Sample Capacity | 50 mL (max per rotor position) |
| Temperature Range | Ambient, 30–80 °C (1 °C increments) |
| Vacuum Level | Down to 10 mbar |
| Rotational Speed | 1465 rpm |
| Cold Trap Temperature | −50 °C |
| Cold Trap Operation Modes | Manual Defrost / Auto-Defrost / Continuous Condensation |
| Rotor Configurations | 48 × 1.5 mL tubes, 12 × 15 mL tubes, 8 × 50 mL tubes, 96-well microplates |
| Operating Modes | Water, Alcohol, Other Solvent Profiles |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | QUATTRO |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 80 °C (adjustable in 1 °C increments) |
| Vacuum Level | 2 mbar |
| Rotational Speed | 1130 rpm |
| Cold Trap Temperature | −50 °C |
| Cold Trap Modes | Manual Defrost / Auto Defrost / Continuous Condensation |
| Rotor Configurations | 200 × 1.5 mL tubes, 72 × 15 mL tubes, 36 × 50 mL tubes, 96-well microplates |
| Operating Modes | Water, Alcohol, Other Solvents |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | Rocket Synergy2 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | +5 °C to 60 °C (±1 °C accuracy) |
| Temperature Control Precision | ±1 °C across 30–80 °C operating band |
| Rotational Speed | 1800 rpm |
| Relative Centrifugal Force (RCF) | 700 × g |
| Maximum Sample Volume per Vessel | 450 mL |
| Standard Capacity | 6 positions (450 mL each) |
| Expandable Capacity | 18 positions with Puck accessory |
| Sample Vessel Options | 60 mL, 250 mL, 400 mL, 450 mL |
| Automated Solvent Addition | Up to 100 L total (via integrated peristaltic dosing module) |
| Ultimate Vacuum | 3 mbar (oil-free PTFE diaphragm pump) |
| Cold Trap | Dual-stage, frost-free, auto-drain capable |
| Real-time Monitoring | Stroboscopic viewing window |
| Programmability | 15 user-storable methods |
| Data Interface | USB for method upload/download and audit log export |
| SampleGenie™ Compatibility | Yes (direct-to-vial concentration & quantitative endpoint control) |
| Dri-Pure® Anti-Bumping Technology | Integrated |
| Brand | GengYu |
|---|---|
| Origin | Zhejiang, China |
| Model | RE-5000A |
| Capacity | 5 L |
| Ultimate Vacuum | 0.098 MPa |
| Rotation Speed | 0–200 rpm |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Cooling Area | 0.26 m² |
| Power Supply | 220 V / 50 Hz |
| Total Power | 1560 W |
| Rotating Motor Power | 40 W |
| Lifting Motor Power | 20 W |
| Heating Power | 1500 W |
| Lift Stroke | 90 mm |
| Net Weight | 30 kg |
| Dimensions (W×D×H) | 690 × 440 × (825–915) mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | TUR/K |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power Consumption | 205 W |
| Weight | 19 kg |
| Dimensions (W × D × H) | 330 × 450 × 420 mm |
| Application | Laboratory-scale waste gas scrubbing and aqueous effluent conditioning |
| Maintenance Requirement | Minimal (no consumable scrubbing media required) |
| Compliance | Designed for integration into GLP-compliant laboratory workflows |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAP450 |
| Instrument Type | Quartz Glass Distillation Apparatus |
| Heating Method | Electric |
| Cooling Method | External Circulating Chiller or Tap Water |
| Distillation Rate | 30 samples/hour |
| Heating Position | 1-place |
| Power Consumption | 2200 W |
| Voltage/Frequency | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 527 × 390 × 697 mm |
| Weight | 34 kg |
| Water Consumption | ~3 L/min |
| Typical Distillation Time | 3 min 30 s |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Recovery Rate | >99.5% |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | NORMAG Vacuum Batch Distillation System |
| Construction Material | High-purity quartz glass (Duran®-grade) |
| Vacuum Capability | Up to 10⁻⁶ mbar |
| Tower Types Available | Packed column, sieve plate column, Vigreux column, micro-rotating band column |
| Thermal Insulation | High-vacuum silvered jacket (10⁻⁶ mbar interlayer) |
| Visual Access | Full-length vertical observation window |
| Structural Feature | Axial thermal expansion compensation corrugated section |
| Control Interface | PC-based LabVIEW-compatible digital control system |
| Compliance | Designed for GLP-compliant operation and ASTM D2892 / ISO 6617 applicability |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHD-1600 |
| Pricing | Upon Request |
| Brand | GiAim |
|---|---|
| Model | Auto R1 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Room Temperature +5°C to +100°C |
| Temperature Control Accuracy | ±1°C |
| Vacuum Control Range | 0.1–100 mbar |
| Vacuum Control Accuracy | ±0.1 mbar |
| Maximum Sample Capacity | 180 × 1.5 mL centrifuge tubes |
| Rotational Speed Range | 800–2000 rpm |
| Max Relative Centrifugal Force (RCF) | 530 × g |
| Timer Range | 0–9999 min |
| Ultimate Vacuum | ≤0.2 mbar |
| Noise Level | ≤55 dB(A) |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (L×D×H) | 480 × 370 × 290 mm |
| Weight | 30 kg |
| Chamber Material | 304 Stainless Steel with PTFE-coated components and borosilicate glass viewport |
| Vacuum Release Valve | Imported solenoid-controlled automatic release valve |
| Built-in Delayed Vacuum Initiation | Engages vacuum only after rotor reaches set speed |
| Real-time Centrifugation Imaging | Integrated optical viewing system enabling non-intrusive sample monitoring during operation |
| Pre-stored Programs | 30 user-defined protocols |
| Quick-access Program Keys | 4 dedicated hardware buttons |
| Drive System | Dual-rotor electromagnetic drive architecture |
| Corrosion Resistance | Full chamber and vacuum path engineered for compatibility with chlorinated solvents, acetonitrile, methanol, ethyl acetate, and other common organic media |
| Brand | GiAim |
|---|---|
| Model | Auto R1-Plus |
| Type | Vacuum Centrifugal Concentrator |
| Cooling Capability | Cryogenic (-5 °C to +100 °C) |
| Rotational Speed Range | 800–2000 rpm |
| Max Relative Centrifugal Force (RCF) | 530 ×g |
| Vacuum Control Range | 0.1–100 mbar |
| Vacuum Control Accuracy | ±0.1 mbar |
| Ultimate Vacuum | ≤0.2 mbar |
| Temperature Control Accuracy | ±1 °C |
| Timer Range | 0–9999 min |
| Chamber Pre-cooling | Yes |
| Real-time Centrifugal Imaging | Yes |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (L×D×H) | 608×370×330 mm |
| Weight | 46 kg |
| Chamber Material | 304 Stainless Steel with PTFE Coating |
| Rotor Capacity | Up to 180 × 1.5 mL Tubes |
| Programmable Methods | 30 User-Stored Protocols |
| Quick-Access Program Keys | 4 |
| Dual-Rotor Electromagnetic Drive System | Yes |
| Automatic Pressure Release Valve | Integrated, Import-Sourced |
| Brand | GiAim |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CV100-DNA |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Rotational Speed Range | 300–1800 rpm |
| Temperature Settings | Ambient, 30°C, 45°C, 60°C |
| Chamber Coating | PTFE (Teflon®) |
| Structural Materials | 304 Stainless Steel (rotor, internal tubing) |
| Control Interface | LCM segmented LCD panel with microprocessor control |
| Drive System | AC frequency-converter induction motor, electromagnetic drive |
| Condensation Method | Inline evaporator coil suspended in vapor path |
| Vacuum Interface | External vacuum pump required |
| Cold Trap | Modular, standalone unit |
| Exhaust Management | Integrated exhaust ducting with optional nitrogen purge and particulate/chemical filtration |
| Brand | GiAim |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CV300 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient +5°C to 80°C (chamber) |
| Cold Trap | −50°C |
| Sample Capacity | 600 mL |
| Rotational Speed | 300–1800 rpm |
| Max RCF | 430 × g |
| Timer Range | 0–9999 min |
| Ultimate Vacuum | ≤30 Pa |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (L×W×H) | 520 × 360 × 240 mm (main unit) |
| Weight | 56 kg |
| Total Power Consumption | 1200 W |
| Brand | GiAim |
|---|---|
| Model | CV400 |
| Type | Vacuum Centrifugal Concentrator |
| Temperature Range | +5–80 °C (Chamber), –50 °C (Cold Trap) |
| Sample Capacity | 600 mL |
| Rotational Speed | 300–1800 rpm |
| Max RCF | 430 × g |
| Timer Range | 0–9999 min |
| Ultimate Vacuum | ≤30 Pa |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (Concentrator) | 520 × 360 × 240 mm |
| Dimensions (Cold Trap) | 590 × 210 × 430 mm |
| Weight | 56 kg |
| Construction | Teflon-coated rotor chamber, 304 stainless steel tubing & rotor, LCM segment LCD controller, brushless AC frequency-controlled motor |
| Brand | GiAim |
|---|---|
| Model | CV600 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | −5 °C to 80 °C (Cold Trap: −60 °C) |
| Sample Capacity | 2000 mL |
| Rotational Speed | 300–1800 rpm |
| Max RCF | ≥430 ×g |
| Timer Range | 0–9999 min |
| Ultimate Vacuum | ≤30 Pa |
| Noise Level | ≤60 dB(A) |
| Power Consumption | 1500 W (Main Unit) + 500 W (JM50-Plus Cold Trap) |
| Dimensions (L×D×H) | 600×370×330 mm (Main Unit) |
| Weight | 76 kg (Main Unit) |
| Construction | 304 Stainless Steel with PTFE Coating |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | GiAim |
|---|---|
| Origin | Beijing, China |
| Model | CV800 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient +5°C to 80°C |
| Sample Capacity | 200 × 1.5 mL tubes (2000 mL total) |
| Rotational Speed | 300–1800 rpm |
| Max RCF | 630 × g |
| Timer Range | 0–9999 min |
| Cold Trap Temperature | ≤ −60°C |
| Cold Trap Capacity | 2000 mL |
| Ultimate Vacuum | ≤ 30 Pa |
| Noise Level | ≤ 60 dB(A) |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (L×D×H) | 590 × 445 × 292 mm |
| Weight | 42 kg |
| Brand | GiAim |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MC-2 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient +5°C to 70°C |
| Rotational Speed | 300–1800 rpm |
| Max Relative Centrifugal Force (RCF) | 390 × g |
| Timer Range | 0–9999 min |
| Vacuum Pump Flow Rate | 28 L/min |
| Ultimate Vacuum | <13 mbar |
| Noise Level | ≤60 dB(A) |
| Total Power Consumption | 750 W |
| Dimensions (L×D×H) | 578×360×353 mm |
| Weight | 38 kg |
| Chamber Coating | PTFE (Teflon®)-coated |
| Tubing Material | PTFE |
| Control Interface | One-touch Start/Stop |
| Safety Features | Automatic Venting on Power Loss, Nitrogen Purge Capability with Inlet Filter |
| Brand | GiAim |
|---|---|
| Model | MC-8 |
| Type | Vacuum Centrifugal Concentrator |
| Origin | Beijing, China |
| Rotational Speed Range | 300–1800 rpm |
| Max RCF | ≥430 × g |
| Temperature Control Range | 0–75 °C (1 °C increments) |
| Cold Trap Temperature | −50 °C |
| Vacuum Limit | ≤30 Pa |
| Timer Range | 0–9999 min |
| Recovery Bottle Capacity | 2000 mL |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (L×D×H) | 560 × 590 × 325 mm |
| Weight | 60 kg |
| Brand | RSJ |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Glimmer |
| Pricing | Upon Request |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | < 1 ppt |
| Total Organic Carbon (TOC) | < 3 ppb (real-time online monitoring) |
| Particles (> 0.1 µm) | < 1 particle/mL |
| Feed Water | Municipal tap water, 5–40 °C, 1–6 bar pressure |
| Maximum Flow Rate | 2 L/min |
| TOC Measurement Range | 0.1–999 ppb |
| Integrated Reservoir Capacity | 40 L |
| Power Supply | AC 100–240 V, 50 Hz |
| Power Consumption | 120 W |
| Dimensions (Pre-treatment + Tank Unit) | 339 × 410 × 904 mm (W×D×H) |
| Dimensions (Main Unit) | 374 × 508 × 538 mm (W×D×H) |
| Net Weight (Pre-treatment + Tank Unit) | 15 kg |
| Net Weight (Main Unit) | 24 kg |
| Brand | GLOBUS |
|---|---|
| Origin | Italy |
| Application Scope | Laboratory to Industrial Scale |
| Construction Material | FDA- and GMP-compliant 316L Stainless Steel |
| Condenser Configuration | Internal Integrated Steam Condensation Chamber |
| Separatory Funnel | Double-jacketed Borosilicate Glass with Independent Temperature Control |
| Cooling System | Closed-loop Water Circulation Circuit |
| Safety Features | Calibrated Heat Meter + ASME-certified Safety Valve |
| Standard Vessel Capacity | 20–500 L |
| Custom Options | Extended-volume vessels & Dedicated Steam Generators Available |
| Brand | GLOBUS |
|---|---|
| Origin | Italy |
| Equipment Type | Sub-boiling Distillation Apparatus |
| Application Scope | Laboratory & Industrial Scale |
| Compliance Context | Designed for GLP-compliant solvent recovery and thermal-sensitive compound processing |
| Brand | Gongyi Yuhua Instrument |
|---|---|
| Origin | Henan, China |
| Model | YRE-2050A (50 L) |
| Capacity | 50 L |
| Ultimate Vacuum | < 2000 Pa |
| Rotation Speed | 0–120 rpm |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Power | 8 kW |
| Rotating Flask Capacity | 50 L |
| Collection Flask Capacity | 20 L |
| Motor Power | 180 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Construction | Borosilicate Glass (3.3), Stainless Steel & Aluminum Alloy Frame, Fluoroelastomer Seals |
| Brand | Gongyi Yuhua Instrument |
|---|---|
| Origin | Henan, China |
| Model | YRE-5299 |
| Capacity | 1 L (standard), optional 2 L |
| Ultimate Vacuum | −0.098 MPa |
| Rotation Speed | 0–120 rpm (stepless) |
| Bath Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±2 °C |
| Motor Power | 40 W |
| Total Power Consumption | 1000 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Vertical Lift | 150 mm (motorized) |
| Condenser Type | Dual-layer vertical coil |
| Material of Contact Parts | High-borosilicate glass (3.3) and PTFE |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GPC 1000 |
| Quotation | Upon Request |
| Flow Rate | Not Applicable (Fixed-Volume Fraction Collection Mode) |
| Maximum Pressure | Not Specified |
| Flow Stability | Not Specified |
| Auto-Sampler Volume Range | Up to 10 mL per injection |
| Auto-Sampler Capacity | Configurable via modular rack system |