| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Model | ROTAVISC hi-vi I Complete |
| Viscosity Range | 200 – 80,000,000 mPa·s |
| Temperature Range | −100 °C to 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Measurement Range | 1.4374 mN·m |
| Full-Scale Accuracy | ±1 % FSR |
| Repeatability | ±0.2 % FSR |
| Display | 4.3″ TFT touchscreen |
| Interfaces | RS232, USB |
| Power Supply | 100–240 V AC, 50/60 Hz |
| IP Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Compliance | DIN EN 60529, CE, RoHS |
| Brand | IKA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-assembled) |
| Model | ROTAVISC hi-vi I COMPLETE |
| Instrument Type | Portable Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 200 – 80,000,000 mPa·s |
| Temperature Accuracy | ±1% Full Scale Reading (FSR) |
| Speed Range | 0.01 – 200 rpm (infinitely variable) |
| Display | 4.3-inch TFT touchscreen with real-time viscosity curve plotting |
| Standard Accessories | SP7–SP12 spindle set, spindle guard stand, integrated Pt100 temperature probe |
| Measurement Accuracy | ±1% FSR |
| Repeatability | ±0.2% FSR |
| Compliance | ASTM D2196, ISO 2555, USP <911>, GLP-compliant data logging capability |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Benchtop Rotational Viscometer |
| Viscosity Range | 200 – 80,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | 4.3″ TFT touchscreen |
| Connectivity | RS-232, USB |
| Protection Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ROTAVISC hi-vi II Complete |
| Instrument Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 800 – 320,000,000 mPa·s |
| Temperature Range | −100 – 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Range | Up to 5.7496 mN·m |
| Full-Scale Accuracy | ±1 % FSR |
| Repeatability | ±0.2 % FSR |
| Display | 4.3″ TFT touchscreen |
| Interfaces | RS232, USB |
| Protection Rating | IP40 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Benchtop Rotational Viscometer |
| Viscosity Range | 800 – 320,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Range | up to 5.7496 mN·m |
| Display | 4.3″ TFT touchscreen |
| Interface | RS-232, USB |
| Compliance | DIN EN 60529 (IP40), CE, RoHS |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Weight | 7.1 kg |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01–200 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | TFT touchscreen |
| Interfaces | RS-232, USB |
| Protection Class | IP40 |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Operating Ambient | 0–40 °C, ≤80% RH |
| Compliance | DIN EN 60529, CE, RoHS |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | ROTAVISC LO-VI COMPLETE |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Range | 5–40 °C |
| Temperature Resolution | ±1 °C |
| Temperature Accuracy | ±1 °C |
| Display | 4.3″ TFT touchscreen |
| Measurement Accuracy | ±1 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Speed Control | Continuously variable (RAMP gradient function supported) |
| Included Accessories | SP1–SP4 standard spindle set, ROTASTAND manual lift stand, PT100 temperature probe, guard rail, USB A-to-Micro-B cable (2 m) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 15–6,000,000 mPa·s |
| Temperature Range | −100 to 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01–200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | 4.3″ TFT Touchscreen |
| Interfaces | RS-232, USB |
| Protection Rating | IP40 |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ROTAVISC me-vi Complete |
| Instrument Type | Benchtop Fixed-Position Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Torque Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1 % |
| Viscosity Repeatability (FSR) | ±0.2 % |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Interface | RS232, USB |
| IP Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Measurement Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1% |
| Viscosity Repeatability (FSR) | ±0.2% |
| Display | 4.3″ TFT Touchscreen |
| Interface | RS-232, USB |
| IP Rating | IP40 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Range | ROTAVISC lo-vi / me-vi / hi-vi I / hi-vi II Complete |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Control Range | −100 °C to +300 °C |
| Temperature Resolution | 0.1 K |
| Accuracy | ±1 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Speed Control | Continuously Variable (0.01–1,000 rpm) |
| Brand | INSTRON |
|---|---|
| Origin | Italy |
| Manufacturer | CEAST (INSTRON Group) |
| Type | Capillary Rheometer |
| Models | CEAST SR20 / CEAST SR50 |
| Force Range | 20 kN (SR20), 50 kN (SR50) |
| Barrel Diameter | 15 mm standard |
| Sample State | Solid (melted in situ) |
| Dual-Barrel Configuration | Yes |
| Independent Load Cells | Two (one per barrel) |
| Barrel Pressure Sensors | Integrated |
| Compliance | ASTM D3835, ISO 11443, ISO 6721-6, USP <1043>, GLP/GMP-ready software architecture |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | JMP2000A |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Interfacial Rheometer |
| Bearing Type | Mechanical Bearing |
| Minimum Rotational Speed | 10⁻⁴ rpm |
| Frequency Range | 10⁻³–628 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | < 100 nN·m |
| Surface Tension Range | 0–150 mN/m |
| Resolution | < 0.01 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Configuration | Langmuir-type |
| Trough Dimensions | 80 mm × 200 mm × 8 mm (W × L × H) |
| Max Active Area | 96.6 cm² |
| Min Active Area | 19.32 cm² |
| Barrier Type | Leakproof / Barrier / Custom Hollow Barrier |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | < 150 W |
| Operating Temperature | Ambient |
| Operating Humidity | 30–85% RH |
| Constant-Speed Compression | Period 1–1000 s, Area Change 0–80% |
| Sinusoidal Mode | Period 1–300 s, Amplitude 5–15% |
| Exponential Mode | Period 100–1000 s, Area Change 0–80% |
| Step-Change Mode | Duration 1–10 s, Area Change 10–30% |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JOS06 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Interfacial Rheometer |
| Bearing Type | Mechanical Bearings |
| Minimum Rotational Speed | 10⁻⁴ rpm |
| Frequency Range | 10⁻³–628 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | < 100 nN·m |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±1 °C (±0.1 °C within 100 °C) |
| Quartz Plate Spacing | 0.05–2 mm |
| Sample Area | Ø25 mm |
| Optical Resolution | 25 pixels/µm |
| Oscillation Frequency Range | 0.01–10 Hz |
| Steady-State Shear Rate Range | 0.001–500 rpm (controlled to ±0.01 rpm at low end) |
| Observation Port | Wide-field transmission & polarized light path |
| CCD System | Color, 3-axis motorized positioning |
| Objective Working Distance | 7 mm |
| Top & Bottom Quartz Plates | Independently motorized, heated via integrated heating plates, temperature monitored by Pt100 sensors |
| Removable Cover & Optional Quartz Plate Sets | Supported for rapid sample exchange and contamination control |
| Origin | USA |
|---|---|
| Manufacturer | Kaltec (USA) |
| Instrument Type | Rotational Rheometer |
| Max Shear Rate | 1–1.38×10⁵ s⁻¹ (standard), up to 1.85×10⁵ s⁻¹ (upgraded) |
| Torque Range | 1.0×10⁴–1.8×10⁷ dyn·cm |
| Shear Stress Range | 80–6.0×10⁵ dyn/cm² |
| Recommended Viscosity Range | 1–4.5×10³ cP (10⁻² P) |
| Weight | 62 kg |
| Dimensions (H×W×D) | 81×64×46 cm |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | EMS-1000S |
| Instrument Type | Rotational Viscometer (Fixed-Base, Non-Contact) |
| Operating Environment | Ambient Temperature (10–30°C), ≤85% RH (non-condensing) |
| Viscosity Range | 0.1–1,000,000 mPa·s (dependent on sphere diameter and material) |
| Temperature Range | 0–200°C |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.1°C |
| Minimum Sample Volume | 90 µL (with optional micro-cell & 2 mm sphere) |
| Rotational Speed Range | 500–1000 rpm |
| Speed Stability | ±3% |
| Viscosity Repeatability | RSD ≤3% (per KEM standard test conditions) |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | KSV NIMA ISR Flip |
| Instrument Type | Interfacial Rheometer |
| Sample Viscosity Range | Low-viscosity liquids |
| Sample State | Liquid |
| Bearing Type | Mechanical bearing |
| Frequency Range | 0.01–10 Hz |
| Torque Resolution | 0.001 mN·m |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | iVisc (LMV 830) |
| Temperature Range | −20 to 150 °C |
| Viscosity Range | 0.3 to 30,000 mm²/s |
| Timing Resolution | 10 ms |
| Detection Method | Optical (Near-Infrared) |
| Power Consumption | 1 W (USB-powered) |
| Dimensions (W × D × H) | 95 × 96 × 425 mm |
| Net Weight | 1.4 kg |
| Operating System Compatibility | Windows 7–11 |
| Max. Simultaneous Units per PC | 2 |
| Recommended Flow Time | 30–1000 s |
| Sample Temperature Accuracy | ±0.01 °C (when used with LAUDA thermostats) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Instrument Type | Fixed-Position Capillary Viscometer |
| Measurement Principle | Kinematic Viscosity via Capillary Flow Time (ASTM D445, ISO 3104, DIN 51562) |
| Temperature Range (Measurement) | –65 °C to +180 °C |
| Time Resolution | 0.01 s |
| Time Range | 0–9999.99 s |
| Kinematic Viscosity Range | 0.3–50,000 mm²/s |
| Sample Capacity | Up to 160 samples/10 h |
| Compliance | ASTM D445/D446/D2270, ISO 3104/3105/2909, IP 71, DIN 51562-1–3 |
| Automation Modules | VAS Auto-Sampler (2-/4-position), VRM Auto-Clean & Dry (1-/2-channel, HT option up to 180 °C), BE Titration Module (665-type burette), S5 Infrared Timing Measurement Station |
| Software | Windows-based PVS Control Suite with GLP-compliant audit trail, user management, and report generation per 21 CFR Part 11 requirements |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Type | Calibrated Capillary Viscometer Set (Ubbelohde Type 1, Dilution Ubbelohde, Micro-Ubbelohde, Cannon-Fenske Routine, Micro-Ostwald) |
| Compliance | ISO 3105, DIN 51562, ASTM D2515, BS 188, NFT 60-100 |
| Capillary Constants | 0.003–30.0 mm²/s per division |
| Viscosity Range | 0.7–7576 mm²/s (cSt) |
| Accuracy | ±0.2% (Ubbelohde & Dilution), ±0.3% (Cannon-Fenske), ±0.5% (Micro variants) |
| Volumes | 2–75 mL |
| Total Lengths | ~245–290 mm |
| Optional Integration | LAUDA VRM Automatic Cleaning Module, LAUDA Transparent Thermostats (e.g., Alpha Series), LAUDA Viscosity Measurement Systems |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | LS-V |
| Pricing | Upon Request |
| Brand | LISICO |
|---|---|
| Model Series | SRV / SRD / DVP / DVM |
| Measurement Principle | Torsional Resonance (Viscosity & Density) |
| Viscosity Range | 0–3,000 mPa·s (cP), up to 50,000 mPa·s (cP) optional |
| Density Range | 0–1.5 g/mL, extended range available |
| Viscosity Accuracy | ±1% of reading or better (customizable) |
| Density Accuracy | ±0.01 g/mL standard, ±0.001 g/mL optional |
| Viscosity Resolution | 0.001 mPa·s (cP) |
| Density Resolution | 0.001 g/mL |
| Temperature Sensor | Pt1000 (Class B or AA), integrated |
| Operating Temp | −50 to +300 °C (model-dependent) |
| Pressure Rating | up to 207 MPa (30,000 psi) |
| Wetted Materials | 316L SS or Titanium Grade 5 |
| Enclosure Rating | IP68/IP69, Ex ia IIC T2–T6 |
| Response Time | <1 s |
| Sample Volume | 0.7 mL |
| Electrical Interface | M12 connector or fixed cable |
| Process Connection | 3/4″ NPT, sanitary clamp, 1″ NPT, or 1/4″ HP (9/16-18 UNF) |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | DWS RheoLab |
| Temperature Range | 5°C–100°C |
| Frequency Range | 0.1 Hz–10 MHz |
| Minimum Measurable Frequency | 0.1 Hz |
| Maximum Measurable Frequency | 10⁷ Hz |
| Sample Volume Requirement | ≥150 µL |
| Sample State | Liquid |
| Measurement Principle | Diffusing Wave Spectroscopy (DWS) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | LS Instruments RheoSoft v5.x |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | MFR 2100 |
| Sample Volume Requirement | ≥100 µL |
| Frequency Range | 0–100 Hz |
| Gap Adjustment Range | 0.6–30 mm |
| Gap Resolution | 0.625 mm |
| Actuation Mode | Pseudo-Random Squeezing (Patented) |
| Data Acquisition | Real-Time Fourier Transform Analysis |
| Control | Fully Automated Computer-Controlled Gap & Sample Handling |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MLW-400 |
| Quotation | Available upon Request |
| Temperature Range | Ambient to 400 °C ±1 °C |
| Heating Rate | 1–6 °C/min (adjustable in 0.1 °C/min increments) |
| Temperature Accuracy | <±0.5 °C (displayed by PC), Resolution: 0.1 °C |
| Piston Diameter | φ11.28 mm (tolerance: –0.012 mm to –0.05 mm) |
| Piston Cross-sectional Area | 1 cm² |
| Pressure Range | 1–50 MPa ±1% |
| Die Configurations | Φ1×5, Φ1×10, Φ1×20, Φ1×40 mm (diameter × length) |
| Die Material | Tungsten Carbide |
| Power Supply | 220 V AC, 50 Hz, <400 W |
| Brand | MyiP |
|---|---|
| Origin | Shanghai, China |
| Model | DV-1 |
| Instrument Type | Benchtop Fixed Rotational Viscometer |
| Viscosity Range | 1–2×10⁶ mPa·s |
| Accuracy | ±2% (for Newtonian fluids) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Spindles | LV#1, #2, #3, #4 |
| Operating Environment | Ambient temperature |
| Compliance | Conforms to GB/T 265 and JJG 1002 national standards for kinematic and dynamic viscosity measurement |
| Brand | MyiP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NDJ-1 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–1×10⁵ mPa·s |
| Accuracy | ±5% (for Newtonian fluids) |
| Rotors | No. 0 (optional), No. 1–4 |
| Rotational Speeds | 6, 12, 30, 60 rpm |
| Compliance | GB/T 265–1988 |
| Dimensions | 280 × 290 × 450 mm |
| Sample Temperature Control | External bath required (no integrated Peltier or heater) |
| [Origin | Spain |
|---|---|
| Model | VK2000 |
| Power Supply | 100–240 V, 50–60 Hz |
| Operating Temperature | 10–40 °C |
| Relative Humidity | < 80 % |
| Rotational Speed | 200 rpm |
| Rotor Type | Standard ASTM Krebs (KU) Rotor |
| Weight | 8.5 kg |
| Interface | RS232 |
| Viscosity Range | KU: 40.2–141.0 (±0.1 KU) |
| g | 32–1099 (±1.0 g) |
| cP | 27–5274 (±5 cP) |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Compliance | ASTM D562-01, ASTM D856, ASTM D1131] |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VR3000 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NDJ-1 |
| Quotation | Available Upon Request |
| Viscosity Range | 10–100,000 mPa·s |
| Rotors | Four interchangeable spindles (No. 1–4) |
| Speed Settings | 6, 12, 30, and 60 rpm |
| Accuracy | ±5% for Newtonian liquids |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, ≤80% RH |
| Dimensions (L×W×H) | 300 × 300 × 450 mm |
| Net Weight | 1.5 kg (excluding stand) |