Rheometer/Viscometer
Filter
Showing 241–270 of 433 results
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | CONTIFEED |
| Feed Screw Configuration | D20×10D or D20×25D |
| Mounting Position | Rear-mounted to Goettfert RG50 Capillary Rheometer |
| External Cooling | Optional liquid cooling circuit for rapid thermal stabilization of feed zone |
| Design | Compact, modular, tool-free disassembly for cleaning |
| Compliance | Engineered for ISO 11443, ASTM D3835, and ISO 6721-6 compliant capillary rheometry workflows |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | D-melt |
| Capillary Diameter | 9.555 ± 0.01 mm |
| Piston Diameter | 9.48 ± 0.01 mm |
| Temperature Range | 60.00–400.00 °C (optional up to 500 °C), Accuracy: ±0.1 °C |
| Die Diameter | 2.095 ± 0.003 mm, Length: 8.00 ± 0.025 mm |
| Die Material | Tungsten Carbide |
| Standard Weights | 1.200 kg, 2.16 kg, 3.8 kg, 5.0 kg, 10.0 kg, 21.6 kg (±0.5 % tolerance) |
| Timer Resolution | < 0.001 s |
| Position Sensor Resolution | 0.006 mm/pulse |
| Draw Speed Range | 0–44.8 m/min |
| Force Measurement Range | 0–3 N |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | Haul-Off |
| Speed Range | 0–600 m/min (optional up to 2000 m/min) |
| Force Range | 0–1.0 N |
| Force Resolution | 0.05 mN |
| Acceleration Modes | Linear or Exponential |
| Dimensions (L×W×H) | 360 × 300 × 360 mm |
| Weight | 10 kg |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | MBR / MBR-TD |
| Die Diameter | 0.5–10 mm |
| Die Length | 40 mm |
| Temperature Range | 40–350 °C |
| Pressure Range | 1–350 bar |
| Melt Pump Displacement | 0.4 cm³/rpm |
| Pump Speed | 0.1–100 rpm |
| Dynamic MVR Range | 1:1000 |
| Dimensions (L×W×H) | 550 × 175 × 335 mm |
| Weight | ~20 kg |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | PVT500 |
| Maximum Force | 20 kN |
| Barrel Diameter | 9.55 ± 0.01 mm |
| Effective Barrel Length | 170 mm |
| Piston Diameter | 9.53 ± 0.01 mm |
| Temperature Range | Ambient to 500.00 °C |
| Displacement Resolution | 0.053 µm |
| Minimum Velocity | 0.1 µm/s |
| Frame Stiffness | 130 kN |
| Cooling Rate (Compressed Air) | Up to 30 K/min |
| Dimensions (L×W×H) | 798 × 575 × 1945 mm |
| Weight | ~300 kg |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | RCR20 |
| Maximum Force | 20 kN |
| Temperature Range | Ambient to 240 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.2 °C |
| Velocity Range | 5×10⁻⁵ mm/s to 15 mm/s |
| Velocity Resolution | 1.7×10⁻⁶ mm/s |
| Dynamic Rate Ratio | 1:300,000 |
| Capillary Die Ratio | 20:1 |
| Piston Diameter Options | 20 mm / 30 mm / 35 mm |
| Dimensions (Rheometry Mode) | 1130 mm × 650 mm × 1500 mm |
| Dimensions (Rheometry + Curing Mode) | 1130 mm × 650 mm × 2070 mm |
| Weight (Rheometry Mode) | 450 kg |
| Weight (Rheometry + Curing Mode) | 480 kg |
| Compliance | ASTM D5099, ISO 11443, GFT 014-02 |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | RCR75 |
| Maximum Force | 75 kN |
| Capillary Die Ratio | 20:1 |
| Piston Diameters | 20 / 30 / 35 mm |
| Temperature Range | Ambient to 240 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.2 °C |
| Speed Resolution | 6.4 × 10⁻⁷ mm/s |
| Dynamic Speed Ratio | 1:800,000 |
| Acceleration | 0–15 mm/s in 0.35 s |
| Compliance Standards | ASTM D5099, ISO 11443, GFT 014-02 |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Instrument Type | Capillary Rheometer |
| Model | RHEOGRAPH 20 |
| Sample Type | High-Viscosity Thermoplastics & Elastomers |
| Sample State | Solid (Pellets, Granules, Powders) |
| Max Force | 20 kN |
| Temperature Range | 60–400 °C (optional up to 500 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Piston Speed Range | 0.0001–30 mm/s (1:300,000 dynamic range) |
| Capillary Die Diameters | 12.0 / 15.0 / 20.0 / 25.0 mm |
| Barrel Length | 230 mm |
| Piston Length | 285 mm |
| Pressure Sensor Full-Scale Accuracy | ±0.2 % FS |
| Pressure Signal Resolution | 0.005 % FS |
| Dimensions (L×W×H) | 850 × 635 × 1550 mm |
| Weight | 270 kg |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Instrument Type | Capillary Rheometer |
| Maximum Force | 25 / 50 / 75 / 120 kN |
| Temperature Range | 60–400 °C (optional up to 500 °C) |
| Dynamic Speed Ratio | 1:1,000,000 |
| Speed Range | 0.00004–40 mm/s |
| Pressure Sensor Accuracy | ±0.2% FS |
| Pressure Sensor Resolution | 0.005% FS |
| Die Diameter Options | 12.0 / 15.0 / 20.0 / 25.0 mm |
| Piston Diameter Options | 11.99 / 14.99 / 19.99 / 24.99 mm |
| Temperature Control Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Dimensions (L×W×H) | 920 × 700 × 1655 mm |
| Weight | 400–600 kg |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | RHEOTENS 71.97 |
| Speed Range | 0–190 cm/s (0–114 m/min) |
| Force Range | 0–2.0 N |
| Force Resolution | 1 mN |
| Acceleration Modes | Linear or Exponential |
| Dimensions (L×W×H) | 320 × 205 × 195 mm |
| Weight | 20 kg |
| Roller Configuration | Dual traction rollers |
| Compliance | ASTM D3835, ISO 11443, DIN 53736, ISO 25277-1 |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | RTR |
| Capillary Diameter | 0.5–10 mm |
| Capillary Length | 20/60/92 mm |
| Temperature Range | 40–350 °C |
| Pressure Range | 1–350 bar |
| Melt Pump Displacement | 0.37 cm³/rpm |
| Pump Speed | 0.1–100 rpm |
| Dynamic MVR Range | 1:1000 |
| Dimensions (L×W×H) | 550 × 175 × 335 mm |
| Weight | ~70 kg |
| Brand | Goettfert |
|---|---|
| Origin | Germany |
| Model | SSR |
| Capillary Diameter | 0.5–10 mm |
| Capillary Length | 20 / 60 / 92 mm |
| Temperature Range | 40–350 °C |
| Pressure Range | 1–350 bar |
| Melt Pump Displacement | 0.37 cm³/rpm |
| Pump Speed | 0.1–100 rpm |
| Dynamic MVR Range | 1:1000 |
| Dimensions (L×W×H) | 664 × 147 × 361 mm |
| Weight | ~30 kg |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | CaBER 1 |
| Motor Type | Linear Motor |
| Hencky Strain (ε₀) | 10 |
| Applied Strain Rate Range | 0.01–300 s⁻¹ |
| Fluid Strain Rate Range | 10⁻⁵–10 s⁻¹ |
| Shear Viscosity Range | 10–10⁶ mPa·s |
| Plate Diameter | 4–8 mm (standard: 6 mm) |
| Temperature Range | 0–80 °C |
| Filament Diameter Resolution | 10 µm |
| System Response Time | 10 ms |
| Dimensions | 40 × 34 × 60 cm |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | Mars 40 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air-bearing (2 radial + 1 axial) |
| Minimum Rotational Speed | 1×10⁻⁷ rpm |
| Maximum Rotational Speed | 4500 rpm |
| Frequency Range | 1×10⁻⁶ – 100 rad/s |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Motor Inertia | 1×10⁻⁵ kg·m² |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | MARS III |
| Minimum Torque | 0.003 µN·m |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Motor Inertia | 10 µN·m·s² |
| Minimum Rotational Speed | 1.0×10⁻⁸ rpm |
| Maximum Rotational Speed | 1500 rpm (4500 rpm optional) |
| Minimum Oscillation Frequency | 1.0×10⁻⁶ Hz |
| Maximum Oscillation Frequency | 100 Hz |
| Normal Force Range | 0.01–50 N |
| Normal Force Resolution | 0.001 N |
| Temperature Control Range (Peltier) | −60 to 200 °C |
| Temperature Control Range (Electric Heater) | 30 to 300 °C |
| Temperature Control Range (Liquid Circulator) | −40 to 180 °C |
| Temperature Control Range (CTC Radiation/Convection Furnace) | −150 to 600 °C |
| Bidirectional Normal Force Measurement | Yes |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | MiniLab II |
| Instrument Type | Torque Rheometer |
| Screw Configuration | Co-rotating and Counter-rotating Conical Twin-Screw |
| Minimum Speed | 1 rpm |
| Maximum Speed | 360 rpm |
| Frequency Range | 0.1–37.7 rad/s |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Motor Power | 400 W |
| Barrel Volume | 7 cm³ (≈5 g PE) |
| Max Temperature | 350 °C (optional 420 °C) |
| Max Pressure | 200 bar |
| Barrel Material | Stainless Steel (HRC55) |
| Screw Material | Stainless Steel 1.4122 |
| Cooling | Air/Water (350 °C version), Air-only (420 °C version) |
| Flow Path | Integrated Recirculation Channel with Automated Bypass Valve |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Laboratory-Scale Co-Rotating Twin-Screw Extruder |
| Screw Diameter | 11 mm |
| L/D Ratio | 40:1 |
| Drive Power | 1.25 kW |
| Speed Range | 10–1000 rpm (infinitely variable) |
| Max Operating Pressure | 100 bar (with integrated safety monitoring) |
| Temperature Range | Ambient to 350 °C (optional up to 450 °C) |
| Barrel Zones | 8 (1 cooling feed zone + 7 independently heated zones) |
| Footprint | 82 × 48 × 34 cm (L × W × H) |
| Throughput | Up to 2.5 kg/h |
| Minimum Sample Requirement | ~20 g |
| Screw Design | Modular, segmentable for customizable configuration |
| Barrel Configuration | Horizontally split, top barrel section removable |
| Control Interface | Integrated color touchscreen |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Benchtop Controlled-Stress/Controlled-Rate Rotational Rheometer |
| Model | RS 1 |
| Drive System | Air-bearing motor |
| Minimum Rotational Speed | 1.0 × 10⁻³ rpm |
| Maximum Rotational Speed | 1200 rpm |
| Angular Frequency Range (Oscillatory Mode) | 1.0 × 10⁻⁴ – 100 rad/s |
| Maximum Torque | 100 mN·m |
| Torque Resolution | 5 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Motor Inertia | 11 µN·m·s² |
| Normal Force Range | Not specified |
| Normal Force Resolution | Not specified |
| Temperature Control Options | Peltier (–40 to +180 °C), Electric Heating (+20 to +200 °C), Liquid Circulator (–40 to +180 °C) |
| Optional Accessories | Star Geometry, SHRP Asphalt Testing System, Anti-Slip System |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | RS6000 |
| Motor Technology | 4th-generation vector-controlled motor |
| Torque Range | 0.005 µN·m (min) to 200 mN·m (max) |
| Torque Resolution | 0.5 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Rotational Speed Range | 1.0×10⁻⁷ – 1500 rpm (up to 4500 rpm optional) |
| Oscillation Frequency Range | 1.0×10⁻⁵ – 100 Hz |
| Normal Force Range | ±0.01–50 N |
| Normal Force Resolution | 0.001 N |
| Temperature Control | Peltier (−60 to 200 °C), Electric Heater (30 to 300 °C), Liquid Circulator (−40 to 180 °C) |
| Data Acquisition Rate | 2.5 ms per point |
| Compliance | ASTM D4402, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11-ready software architecture |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Instrument Type | Rotational Viscometer / Compact Rheometer |
| Model | VT iQ |
| Viscosity Range | 0.001 – 600,000 Pa·s |
| Angular Velocity Range | 0.001 – 157 rad/s |
| Torque Range | 0.2 – 100 mN·m |
| Shear Stress Range | 0.7 – 63,660 Pa |
| Shear Rate Range | 0.004 – 11,415 s⁻¹ |
| Temperature Control | Peltier (–5 °C to 160 °C, depending on geometry) and Liquid Circulator (–20 °C to 180 °C) |
| Connectivity | USB, TCP/IP, USB flash drive interface for RheoApp, keyboard & barcode scanner ports |
| Dimensions (W × L × H) | 270 × 500 × 500 mm |
| Weight | 18 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | VT1 Plus / VT2 Plus |
| Instrument Type | Battery-Powered Rotational Viscometer |
| Viscosity Range | VT1 Plus: 1.5–330 mPa·s |
| VT2 Plus | 0.3–4000 dPa·s |
| Temperature Capability | Up to 150 °C |
| Rotational Speed | 62.5 rpm |
| Repeatability | ±1% of Full Scale Deflection (FSD) |
| Standard Accuracy | ±5% FSD |
| Display | Digital LCD |
| Power | 4 × AA batteries (included), with optional charger |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Instrument Type | Rotational Viscometer |
| Model | VT550 |
| Measurement Principle | Searle (rotating spindle) geometry |
| Viscosity Range | 2–10⁷ mPa·s |
| Speed Range | 0.5–800 rpm |
| Torque Range | 0.1–50 mN·m (up to 400 rpm) |
| Temperature Range | −40 °C to +350 °C (with external temperature control unit) |
| Compliance Standards | ISO 2555, ISO 3219, DIN 53018, DIN 53019 |
| Operating Modes | Controlled Rate (CR), Controlled Deformation (CD) |
| Predefined Protocols | 10 factory-programmed routines |
| Display | Integrated LCD with digital readout |
| Output | Real-time digital display and optional thermal printout |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | DC-1006N |
| Temperature Range | −10 to 100 °C |
| Temperature Stability | ±0.05 °C |
| Circulation Flow Rate | 6 L/min |
| Bath Opening Diameter | φ90 mm |
| External Dimensions (L×W×H) | 610×370×460 mm |
| Circulation Type | Internal Only |
| Construction | Stainless Steel Interior and Work Surface |
| Control System | Microprocessor-Based PID with Digital Display and Setpoint Programming |
| Refrigeration | Hermetically Sealed Compressor with Overheat and Overcurrent Protection |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DC-2006N |
| Price | Upon Request |
| Temperature Range | −20 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Circulation Flow Rate | 6 L/min |
| Bath Opening Diameter | Ø90 mm |
| External Dimensions (W×D×H) | 610 mm × 370 mm × 460 mm |
| Construction | Stainless Steel Inner Tank and Work Surface |
| Control System | XMT Series Digital PID Controller with LED Display |
| Cooling System | Hermetically Sealed Compressor with Overheat and Overcurrent Protection |
| External Cooling Capability | Yes |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | WS-2 |
| Temperature Range | RT+10–80 °C (standard), 50–210 °C (high-temp variants) |
| Display Resolution | 0.1 °C / 0.01 °C / 0.001 °C |
| Temperature Stability | ±0.1 °C / ±0.02 °C / ±0.002 °C |
| Bath Opening | Ø65 mm |
| Bath Depth | 300 mm / 350 mm / 400 mm |
| Transparent Viewing Window | 4-sided |
| Total Power | 1.0–1.9 kW |
| Communication Interface | RS-232 or RS-485 (optional) |
| Temperature Ramp Control | Optional programmable ramp |
| Sensor Protection | Dual-limit overtemperature cutoff, sensor fault detection |
| Calibration Correction | Adjustable offset for temperature sensor error compensation |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-1S |
| Viscosity Range | 1–100,000 mPa·s |
| Standard Spindles | #1–#4 |
| Rotational Speeds | 6, 12, 30, 60 rpm |
| Accuracy | ±2% (for Newtonian fluids) |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% |
| Dimensions | 380 × 320 × 390 mm |
| Net Weight | 4.5 kg |
| Optional Spindle | #0 (0.1–10 mPa·s) |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-5S |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–1×10⁵ mPa·s |
| Rotors | Standard #1–#4, Optional #0 (0.1–10 mPa·s) |
| Rotational Speeds | 6, 12, 30, 60 rpm |
| Accuracy | ±2% (for Newtonian liquids) |
| Display | Backlit LCD with bilingual (Chinese/English) UI |
| Interface | RS-232 serial port |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Environment | 5–35 °C, ≤80% RH |
| Dimensions | 380 × 320 × 390 mm |
| Net Weight | 4.5 kg |
| Brand | Hengping |
|---|---|
| Model | NDJ-8S |
| Type | Rotational Viscometer |
| Viscosity Range | 2–1×10⁶ mPa·s |
| Spindle Set | Standard #1–#4 spindles (optional #0 spindle for 0.1–10 mPa·s) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±1% for Newtonian liquids |
| Display | Backlit LCD with dual-language (English/Chinese) interface |
| Communication | RS-232 serial port |
| Optional Accessories | PT100 temperature sensor, thermal printer, PC software suite |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Environment | 5–35 °C, ≤80% RH |
| Dimensions (W×D×H) | 380×320×390 mm |
| Net Weight | 4.5 kg |
| Brand | Hmsense |
|---|---|
| Origin | United Kingdom |
| Model | VL7-100B |
| Instrument Type | Oscillating Viscometer |
| Viscosity Range | 0–100,000 cP |
| Temperature Range | –20 to +120 °C |
| Sample Volume (Standard) | 100 mL |
| Sample Volume (Mini Probe Option) | 10 mL |
| Repeatability | <1% |
| Probe Weight | 700 g (Standard), 500 g (Mini) |
| Display Unit Weight | 500 g |
| Total Length | 305 mm (Standard), 215 mm (Mini) |
| Wetted Materials | ASTM A240 Grade 316 Stainless Steel |
| Housing Material | Delrin® (Polyoxymethylene, POM) |
| IP Rating | IP65 |
| Power Supply | 4 × AA Alkaline Batteries |
| Integrated Temperature Sensor | Yes |
| Calibration Correction | Real-time viscosity/temperature compensation |
| Sensing Surface Finish | Electro-polished Alloy C-22 (N06022) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | ROTATEMP Package |
| Instrument Type | Rotational Viscometer Accessory System |
| Mounting Style | Benchtop Fixed Installation |
| Operating Environment | Ambient Temperature |
| Viscosity Range (with ROTAVISC) | 1–320,000,000 mPa·s |
| Max. Operating Temperature | 300 °C |
| Minimum Sample Volume | 7 mL |
| Maximum Sample Volume | 13 mL |
| Sample Vessel | Dedicated cylindrical chamber |
| Dimensions (W×D×H) | 265 × 220 × 270 mm |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Ingress Protection | IP40 per DIN EN 60529 |
| Interface | RS232 |
| Voltage | 220–230 V AC |
| Frequency | 50/60 Hz |
| Rated Power Input | 300 W |
| Standby Power Consumption | 1.6 W |