Seal Test Instrument
Filter
Showing 91–117 of 117 results
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Gas Valve Functional Tester |
| Pricing | Available Upon Request |
| Pressure Range | 300 Pa to 0.6 MPa |
| Timing Range | 0 to 999.9 s (user-configurable) |
| Supply Air Pressure | 0.4–0.8 MPa (clean, dry air) |
| Flow Resolution | 0.001 m³/h |
| Pressure Measurement Accuracy | ±0.2 % of Full Scale |
| Pressure Units | kPa, bar, psi |
| Channel Count | 1 (multi-channel expansion supported) |
| Data Storage | Internal test result logging |
| Communication Interfaces | RS-232 / RS-485 (selectable), RJ45 Ethernet |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 7-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 9.8–11 kg |
| Dimensions | 450 × 270 × 190 mm |
| Brand | SUNS SANS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Medical Device Air-Tightness Tester (Negative Pressure) |
| Pricing | Available Upon Request |
| Test Object | Medical Devices |
| Test Principle | Vacuum-Based Leak Integrity Verification |
| Maximum Test Pressure | −70 kPa |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SAT100 |
| Quotation | Upon Request |
| Pressure Range | 2 kPa to 0.8 MPa (customizable) |
| Timing Range | 0–999.9 s |
| Flow Rate Range | 1000 mL/min (customizable) |
| Pressure Resolution | 0.01 kPa / 1 Pa |
| Flow Resolution | 0.1 mL/min or 0.01 mL/min (configurable) |
| Timing Resolution | 0.1 s |
| Accuracy | ±0.1 % FS |
| Pressure Units | kPa, Pa, bar, psi, sccm |
| Pressure Regulation | Mechanical or Electrically Controlled (selectable) |
| Data Export Interface | USB |
| Channel Count | 1 (multi-channel expansion supported) |
| Communication Interfaces | RS-232 / RS-485 (optional), RJ45 Ethernet |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 7-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Required Air Supply Pressure | 0.4–0.8 MPa |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Net Weight | 9.8–11 kg |
| Dimensions (W×D×H) | 450 × 270 × 190 mm |
| Key | Brand: SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SB015 |
| Pressure Range | 0.035–3 MPa (custom high-pressure options available) |
| Timing Range | 0–999.9 s (user-configurable) |
| Pressure Source | Clean, dry compressed air at supply pressure > test pressure and ≤ 3 MPa |
| Resolution | 0.1 kPa / 1 kPa / 0.0001 MPa |
| Accuracy | ±0.1 % FS |
| Units | kPa, bar, psi, MPa |
| Pressure Regulation | Mechanical or Electronic (optional) |
| Data Export | USB interface |
| Channels | 1 (multi-channel expansion supported) |
| Communication | RS485 (RS232 / RJ45 Ethernet optional) |
| I/O | 6 digital inputs, 6 digital outputs |
| Display | 7-inch LCD touchscreen |
| Power | AC 110–240 V, 50/60 Hz |
| Test Modes | Leak integrity, burst pressure, inversion testing |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 9.8–11 kg |
| Dimensions | 450 × 270 × 190 mm |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SB015-E10 |
| Max Test Pressure Range | 0.035–3 MPa (customizable to higher pressure) |
| Timing Range | 0–999.9 s |
| Pneumatic Supply Requirement | Clean, oil-free compressed air at pressure > test pressure and ≤ 3 MPa |
| Pressure Resolution | 0.1 kPa |
| Pressure Accuracy | ±0.001 MPa |
| Units | kPa, bar, psi, MPa |
| Test Modes | Constant-Pressure Loading, Variable-Pressure Loading, Burst Testing, User-Defined Pressure Profiles |
| Pressure Regulation | Mechanical or Electrically Controlled (configurable) |
| Data Export | Ethernet (RJ45) or USB Flash Drive |
| Independent Channels | 10 |
| Communication Interfaces | RS485, RJ45 Ethernet |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 19-inch industrial-grade touchscreen PC |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Acoustic Noise Level | ≤120 dB(A) |
| Operating Environment | 5–45 °C, ≤80% RH (non-condensing) |
| Real-Time Curve Visualization | Yes |
| Data Storage Capacity | Unlimited (on-board SSD + network backup) |
| Dimensions (W×D×H) | 600 × 800 × 1450 mm |
| Key | Brand: SUNS |
|---|---|
| Model | SBH2000 |
| Pressure Range | 1–3 MPa (optional) |
| Timing Range | 0–999.9 s |
| Supply Air | 0.4–3 MPa (clean, dry) |
| Pressure Resolution | 0.1 kPa / 1 kPa / 0.0001 MPa |
| Accuracy | ±0.2 % FS |
| Units | kPa, bar, psi, MPa |
| Pressure Regulation | Mechanical or Electromechanical (selectable) |
| Data Export | USB |
| Channels | 1 (multi-channel expandable) |
| Communication | RS232/RS485 (optional), RJ45 Ethernet |
| I/O | 6 inputs / 6 outputs |
| Display | 10-inch LCD touchscreen |
| Power | AC 110–240 V, 50/60 Hz |
| Test Modes | Leak Integrity, Respiratory Cycling, Burst Pressure |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 20–22 kg |
| Dimensions | 500 × 305 × 275 mm |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SC10005 |
| Pricing | Available Upon Request |
| Test Range | 5–50 kPa / 5–100 kPa / 5–500 kPa / 10–1000 kPa / 10–1500 kPa |
| Differential Pressure Range | ±2000 Pa |
| Timing Range | 0–999.9 s (user-configurable) |
| Resolution | 0.1 Pa, 0.01 mL/min, 0.001 mL/min |
| Accuracy | ±0.2 % FS |
| Units | kPa, Pa, mL/min, L/min |
| Data Export | USB |
| Channels | 1 (expandable to multi-channel configurations) |
| Communication Interfaces | RS-232/RS-485 (selectable), RJ45 Ethernet |
| I/O Ports | 6 inputs, 6 outputs |
| Display | 10-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Required Air Supply | 0.4–0.8 MPa (clean, dry air) |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 20–22 kg |
| Dimensions | 500 × 305 × 275 mm |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SD4-XXX |
| Pricing | Available Upon Request |
| Test Range | 3–50 kPa / 3–100 kPa / 5–200 kPa / 10–500 kPa / 10–800 kPa / 10–1000 kPa / 35–1500 kPa / 35–2000 kPa |
| Timing Range | 0–999.9 s |
| Pressure Source | 0.4–0.8 MPa (clean, dry air) |
| Resolution | 1 Pa / 10 Pa / 100 Pa |
| Accuracy | ±0.2 % FS |
| Units | kPa, Pa |
| Pressure Regulation | Electrically Controlled (mechanical optional) |
| Channels | 4 (expandable to multi-channel configurations) |
| Communication Interfaces | RS-232 / RS-485 / RJ45 Ethernet |
| I/O Ports | 6 inputs, 6 outputs |
| Display | 10-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 19.8–20 kg |
| Dimensions | 450 × 570 × 290 mm |
| Data Export | USB port |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Model | SDX-XX |
| Pressure Range Options | 3–50 kPa |
| Timing Range | 0–999.9 s (user-configurable) |
| Resolution | 1 Pa / 10 Pa / 100 Pa |
| Accuracy | ±0.2 % FS |
| Pressure Units | kPa, Pa |
| Pressure Regulation | Mechanical or Electropneumatic (selectable) |
| Channels | 2 (expandable to multi-channel configurations) |
| Communication Interfaces | RS-232 / RS-485 / RJ45 Ethernet |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 10-inch capacitive LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Pressure Source Requirement | 0.4–0.8 MPa clean, dry compressed air |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 20–22 kg |
| Dimensions | 500 × 305 × 275 mm (W × D × H) |
| Data Export | USB mass storage support |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SF800 |
| Pressure Range | 10–800 kPa |
| Timing Range | 0–999.9 s |
| Pneumatic Supply | 0.4–0.8 MPa (clean, dry air) |
| Pressure Resolution | 0.1 kPa / 1 kPa / 0.0001 MPa |
| Accuracy | ±0.1 % F.S. |
| Units | kPa, bar, psi, MPa |
| Pressure Regulation | Mechanical or Electromechanical (configurable) |
| Data Export | USB |
| Channel Count | 1 (multi-channel expandable) |
| Communication Interfaces | RS485 (RS232/RJ45 Ethernet optional) |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 7-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Test Modes | Air-tightness, Respiratory Cycling |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 55–60 kg |
| Dimensions | 700 × 570 × 320 mm |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SFH800-2 |
| Pressure Range | 0–500 kPa (dual-tube mode), −80–500 kPa (single-tube mode) |
| Timing Range | 0–999.9 s (programmable) |
| Supply Air | 0.4–0.8 MPa (clean, dry air) |
| Resolution | 0.0001 MPa |
| Accuracy | ±0.2 % FS |
| Units | kPa, bar, psi, MPa |
| Pressure Control | Motorized electric regulation for positive pressure |
| Data Export | Dual USB 2.0 ports |
| Channels | 2 independent test channels (Channel A: dual-tube positive-pressure only |
| Channel B | single-tube positive/negative pressure capable) |
| Network Interfaces | 2 × Ethernet (RJ45) for SCADA/MES/PLC integration |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | Dual 10-inch LCD touchscreens (one per channel) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Test Modes | Respiratory cycle simulation, bidirectional pressure cycling (positive/negative), hold-and-ramp profiles |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Internal Data Storage | 50,000 test records |
| Dimensions | 860 × 740 × 1700 mm (W × D × H) |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Origin Category | Domestic (China-made) |
| Model | SFY80 |
| Quotation | Available upon Request |
| Test Range | 5–50 kPa / 5–95 kPa |
| Timing Range | 0–999.9 s (user-configurable) |
| Pneumatic Supply | Clean, dry air at 0.4–0.8 MPa |
| Pressure Resolution | 1 Pa |
| Accuracy | ±0.2 % of Full Scale (F.S.) |
| Units | kPa, bar, psi, mmHg, mmH₂O |
| Channels | 1 (expandable to multi-channel configurations) |
| Communication Interfaces | RS-232 / RS-485 (selectable), RJ45 Ethernet |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 7-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 9.8–11 kg |
| Dimensions | 450 × 270 × 190 mm |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH300Z-5 |
| Pressure Range | 0–800 kPa |
| Test Range | 10–800 kPa |
| Accuracy | ±0.1% FS |
| Pressure Regulation Accuracy | ±0.05% FS |
| Test Modes | Leak Integrity, Life Cycle, Count-Based Cycling |
| Units | kPa, bar, psi, MPa |
| Supply Air | 0.4–0.8 MPa (clean, dry air) |
| Channels | 5 independent channels |
| Communication Interfaces | RS485 (RS232 / RJ45 Ethernet optional) |
| USB Port | 1 (data export only) |
| Display | 7-inch LCD touchscreen |
| Power Input | AC 110–240 V, 50/60 Hz |
| Max Specimen Length | 350 mm |
| Real-Time Pressure Alerting | Yes |
| Dual-Zone Pressure Control | Upper & Lower Independent Regulation |
| Dimensions (W×D×H) | 1400 × 840 × 1600 mm |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SHD3000Z |
| Pressure Test Range (Leakage) | 5–50 kPa |
| Pressure Test Range (Burst) | 0.035–3 MPa |
| Differential Pressure Range | ±2000 Pa |
| Timing Range | 0–999.9 s |
| Air Supply Requirement | 0.4–0.8 MPa (clean, dry air) |
| Resolution (Leakage) | 0.1 Pa, 0.01 mL/min, 0.001 mL/min |
| Resolution (Burst) | 0.0001 MPa, 0.001 MPa |
| Accuracy | ±0.2 % FS |
| Units | kPa, bar, psi, MPa |
| Pressure Regulation | Mechanical or Electrically Controlled (optional) |
| Data Export | Dual USB ports |
| Channel Count | 2 independent test channels |
| Communication Interfaces | RS485, RJ45 Ethernet (RS232 optional) |
| I/O | 6 digital inputs, 6 digital outputs |
| Display | Dual 10-inch LCD touchscreens |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Test Modes | Respiratory cycling, positive/negative pressure cycling |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Booster Pump Ratio | 3×–5× |
| Dimensions | 900 × 820 × 1700 mm |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SHDC3000 |
| Test Pressure Range | 0.035–3 MPa (customizable to higher pressures) |
| Timing Range | 0–999.9 s |
| Air Supply Requirement | 0.4–3 MPa (clean, dry compressed air) |
| Resolution | 0.1 kPa / 1 kPa / 0.0001 MPa |
| Accuracy | ±0.2 % FS |
| Pressure Units | kPa, bar, psi, MPa |
| Pressure Regulation | Mechanical or Electrically Controlled (optional) |
| Data Export | USB interface |
| Channel Count | 1 (multi-channel expansion supported) |
| Communication Interfaces | RS485, RJ45 Ethernet (RS232 optional) |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 10-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Test Modes | Leak Integrity, Respiratory Cycling, Burst Pressure |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Booster Pump Ratio | 3×–5× |
| Dimensions | 980 × 540 × 1252 mm |
| Brand | SUNS |
|---|---|
| Model | SHH100 |
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Pressure Range | 5–85 kPa / 5–800 kPa |
| Pressure Source | 0.4–0.8 MPa (clean, dry air) |
| Timing Range | 0–999.9 s |
| Resolution | 1 Pa |
| Accuracy | ±0.2 %FS |
| Test Units | kPa, bar, psi, mmHg, mmH₂O |
| Channels | 1 (expandable to multi-channel configurations) |
| Communication Interfaces | RS-232 / RS-485 (selectable), RJ45 Ethernet |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 10-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤80 %RH (non-condensing) |
| Weight | 20–22 kg |
| Dimensions | 500 × 305 × 275 mm |
| Brand | SUNS |
|---|---|
| Model | SKT3000 |
| Pressure Range | 30–3000 kPa (selectable) |
| Test Range | 30–2995 kPa (selectable) |
| Sample Dimensions | 80–230 mm (L) × 20–80 mm (W) × 10–230 mm (H) |
| Accuracy | ±0.2 %FS |
| Pressure Regulation Accuracy | ±1 %FS |
| Timer Range | 0.1–999.9 s (0.1 s resolution) |
| Air Supply | 0.4–0.8 MPa, clean and dry |
| Pressure Resolution | 0.1 kPa |
| Units | kPa, bar, psi, MPa (user-selectable) |
| Pressure Control | Mechanical or Electric (configurable) |
| Data Export | USB interface (1 port, multi-channel support) |
| Communication | RS232/RS485 (optional), RJ45 Ethernet (1 port) |
| I/O | 6 digital inputs, 6 digital outputs |
| Display | 10-inch LCD touchscreen |
| Power | AC 110–240 V, 50 Hz |
| Test Modes | Burst Test, Hold (Hydrostatic) Pressure Test |
| Safety Features | Light curtain interlock, explosion-resistant door |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 1000 kg |
| Dimensions | 950 × 900 × 1800 mm |
| Brand | SUNS |
|---|---|
| Model | SLM5008 |
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Pressure Range Options | 5–50 kPa |
| Flow Range | 2 mL/min – 100 L/min (customizable) |
| Timing Range | 0.0–999.9 s (user-configurable) |
| Resolution | 0.01 mL/min |
| Accuracy | ±0.2 % of Full Scale (F.S.) |
| Units | kPa, bar, psi, mmHg, mmH₂O |
| Data Export | USB interface |
| Communication Interfaces | RS-232 / RS-485 (selectable), RJ45 Ethernet |
| I/O Ports | 6 digital inputs, 6 digital outputs |
| Display | 7-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Pressure Source Requirement | 0.4–0.8 MPa |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 9.8–11.0 kg |
| Dimensions | 450 × 270 × 190 mm |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SLZ10020 |
| Pressure Range | 3–20 kPa / 5–50 kPa / 5–100 kPa / 5–200 kPa / 10–500 kPa / 10–800 kPa |
| Timing Range | 0–999.9 s (user-configurable) |
| Resolution | 1 Pa / 0.01 kPa / 0.1 kPa / 0.1 mL/min |
| Accuracy | ±0.2 % FS |
| Test Units | kPa, Pa, mL/min |
| Channels | 1 (multi-channel configurable) |
| Interface | RS232/RS485 (selectable), RJ45 Ethernet, 6-in/6-out I/O |
| Display | 7-inch LCD touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Pneumatic Supply | Clean, dry air at 0.4–0.8 MPa |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Weight | 9.8–11 kg |
| Dimensions | 450 × 270 × 190 mm |
| Brand | SUNS |
|---|---|
| Model | STC Series |
| Measurement Principle | Direct-Pressure Decay Method |
| Pressure Range Options | 3–50 kPa, 3–100 kPa, 5–200 kPa, 10–500 kPa, 10–800 kPa, 10–1000 kPa, 35–1000 kPa, 25–2000 kPa |
| Timing Range | 0–999.9 s |
| Pressure Source | Clean, Dry Compressed Air (0.4–0.8 MPa) |
| Resolution | 1 Pa |
| Accuracy | ±0.2 % FS |
| Units | kPa, Pa |
| Pressure Regulation | Mechanical or Electrically Controlled (Selectable) |
| Channels | Single Standard, Multi-Channel Configurable |
| Communication Interfaces | RS-232 / RS-485 / RJ45 Ethernet |
| I/O Ports | 6 Inputs, 6 Outputs |
| Display | 7-inch LCD Touchscreen |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤80 % RH (non-condensing) |
| Dimensions | 450 × 270 × 190 mm |
| Weight | 9.8–11 kg |
| Data Export | USB Mass Storage Mode |
| Compliance | Designed for ISO 50001 energy-aware operation |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Auto Dental Irrigator Tester |
| Pressure Range | 0–500 g (0.1 g resolution) |
| Sound Pressure Level Range | 30–120 dB(A) (0.1 dB resolution) |
| Pressure Units | kPa, bar, psi |
| Air Supply Requirement | 0.4–0.8 MPa (clean, dry compressed air) |
| Power Input | AC 110–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤80% RH (non-condensing) |
| Dimensions | 900 × 600 × 1230 mm |
| Weight | 200 kg |
| Display | 7-inch LCD touchscreen |
| Data Storage | Internal test result logging |
| Communication Interfaces | RS-232 / RS-485 (optional), RJ45 Ethernet |
| Data Export | USB flash drive |
| Test Channel | 1 channel (multi-channel expansion supported) |
| Pass/Fail Logic | Configurable pass/fail criteria with audible and visual alerts |
| Brand | SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Negative-Pressure Air-Tightness Tester |
| Quotation | Available Upon Request |
| Test Pressure Range | –70 kPa |
| Key | Brand: SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Floor-Standing Integrated Fixture System |
| Price Range | USD 4,200 – 7,000 |
| Application | IP68 Waterproof Integrity Testing for Smartphone Frames |
| Test Method | Dual-Station Direct-Pressure Air-Tightness Measurement |
| Test Pressure | 22 kPa |
| Custom Integration | Host PC Interface, Barcode Scanner Support, MES Connectivity |
| Brand | TM Electronics |
|---|---|
| Origin | USA |
| Model | BT-1000 |
| Dimensions | 13" W × 15" D × 6.5" H |
| Power | 115 V, 50/60 Hz, 150 W |
| Pressure Range | 0.2–50 psig and 1–100 psi (oil-free, dry air) |
| Time Range | 0.1–1000 s |
| Resolution | 0.5 in H₂O |
| Test Modes | Burst, Creep, Creep-to-Failure, Leak Detection, and combined dual-mode tests (e.g., Creep/Leak, Leak/Burst) |
| Display | 20×16-character LCD with graphical capability |
| Data Storage | 1000 test results |
| Program Memory | 40 user-defined test protocols |
| Statistical Output | X̄-R control charts, histograms, mean, standard deviation, min/max, range, count |
| Interface | DB25 female (print & PLC auxiliary), DB25 male (RS-232 ASCII serial, PC/WINDOWS compatible) |
| Compliance | ISO 11607, ASTM F1140, ASTM F2054 |
| Calibration | NIST-traceable |
| Brand | TME |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Solution |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Detection Principle | Differential Pressure Decay & Mass Flow Measurement |
| Channels | 1–4 Simultaneous or Sequential |
| Pressure Range | –13.5 to 300 psig (customizable) |
| Vacuum Range | –13.5 to 0.5 psig |
| Flow Range | 10–10,000 ccm (customizable) |
| Resolution | 0.0001 psig |
| Data Storage | 100 test configurations + 5,000 result records |
| Interface | RS-232 |
| Calibration | NIST-traceable |
| Compliance | Designed for ISO 9001, ASTM F2096, ASTM D3078, USP <1207>, and GMP-aligned validation protocols |
| Brand | TMI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 75-50 |
| Price | Upon Request |
| Heat Seal Temperature Range | Ambient to 350°C (662°F) |
| Temperature Resolution | ±0.1°C (0.18°F) |
| Temperature Accuracy | ±0.70°C (1.26°F) |
| Hot Tack Load Cell Capacity | 111.2 N (11.3 kgf) |
| Load Accuracy | 0.1% Full Scale |
| Peel Speed Range | 1–200 mm/sec (0.04–7.87 in/sec) |
| Seal Load Cell Capacity | 4448.2 N (453.6 kgf) |
| Load Accuracy | ±0.89 N (±0.09 kgf) |
| Seal Pressure Range | 137.9–2758 kPa (20–400 psi) |
| Pressure Resolution | 0.68 kPa (0.1 psi) |
| Seal Delay Time Range | 0.20–99.99 s |
| Time Resolution | 10 ms |
| Control Timing Accuracy | ±0.025 ms |
| Seal Jaw Length | Up to 203.2 mm (8.0 in) |
| Jaw Width | 12.7–25.4 mm (0.5–1.0 in) |
| Jaw Surface Configurations | Flat, Vertical, Horizontal, Custom, or Standard Geometries |
| Compliance | ASTM F1921, ASTM F2029, ASTM F88, ISO 11607-2, USP <1207> |
| Calibration Standard | ASTM E4 |
| Brand | Zhongke Instrument (ZKDZ) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSSD-01H |
| Pricing | Upon Request |
| Test Range | 0.00–600.00 kPa (standard), up to 1.60 MPa (optional) |
| Accuracy | Better than Class 0.5 |
| Pneumatic Interface | Φ6 mm polyurethane tubing |
| Air Supply Requirement | 0.4–0.9 MPa clean, dry air (user-supplied) |
| Flow Rate Control | 0.01–10 L/min |
| Pressure Holding Time | 0.1 s – 999999.9 s |
| Standard Nozzle Diameter | Φ6 mm (Φ4 mm and Φ1.6 mm optional) |
| Dimensions (L×W×H) | 420 × 320 × 150 mm |
| Test Chamber Footprint | 380 × 260 × 365 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 15 kg |
| Data Storage Capacity | 2000 test records |
| Compliance Standards | ISO 11607-1, ISO 11607-2, ASTM F1140, ASTM F2054, GB/T 10440, GB 18454, GB 19741, GB 17447, GB/T 17876, GB/T 10004, BB/T 0025, QB/T 1871, YBB00252005, YBB 00162002 |