- All
- Favorite
- Popular
- Most rated
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-504 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 60 positions × 1.5 mL vials or 96 positions × 0.5 mL vials |
| Injection Volume Range | 0.1–999.9 µL |
| Column Oven Temperature Range | 4–100 °C |
| UV/Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-150 |
| Instrument Type | Laboratory |
| Pump Pressure Range | 0–40 MPa |
| Flow Rate Range | 0.000–10.000 mL/min |
| Eluent Flow Rate Range | 0.000–10.000 mL/min |
| Maximum Operating Pressure | 35 MPa |
| Operating Temperature Range | 5–35 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | Application-dependent (compatible with common carbonate/bicarbonate, hydroxide, methanesulfonic acid, and other IC eluents) |
| Brand | Labomatic |
|---|---|
| Origin | Switzerland |
| Model | LHP3000 / LMP3000 |
| Instrument Type | High-Pressure Preparative LC System |
| Pump Flow Range | 0.2–1640 mL/min |
| Max Pressure | 600 bar (HDK-51) to 150 bar (HDK-1640) |
| Flow Stability | RSD < 0.1% |
| Piston Stroke | 3.2–17.1 mm |
| Piston Frequency | 0–200 cycles/min |
| Wetted Materials | Sapphire, Ruby, Zirconia Ceramic, PEEK, 1.4435 Stainless Steel |
| Power Supply | 110 / 230 V, 50 / 60 Hz, 1200 VA |
| Dimensions (Controller) | 316 × 142 × 400 mm (W × H × D) |
| Dimensions (Pump Unit) | 316 × 198 × 400 mm |
| Interface Options | 1/4″, 1/8″, 1/16″ |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-433D |
| Instrument Type | Post-column Derivatization Amino Acid Analyzer |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | 40 MPa (400 bar, 6000 psi) |
| Autosampler Injection Volume | 1–500 µL |
| Autosampler Temperature Control | +4 °C to 70 °C (electronic thermostating) |
| Post-column Reactor Temperature Range | Ambient to 180 °C (temperature stability ±0.1 °C) |
| Detection Wavelengths | Simultaneous dual-wavelength detection at 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-501 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–999.9 µL |
| Column Oven Temperature Range | 4–100 °C |
| UV/Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
Show next