Empowering Scientific Discovery

Secam (Beijing) Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSykam
OriginGermany
ModelS-504
Instrument TypeConventional High-Performance Liquid Chromatograph
Flow Rate Range0.001–10.000 mL/min
Maximum Pressure40 MPa
Autosampler Capacity60 positions × 1.5 mL vials or 96 positions × 0.5 mL vials
Injection Volume Range0.1–999.9 µL
Column Oven Temperature Range4–100 °C
UV/Vis Wavelength Range190–800 nm
Data Acquisition Rate10 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSykam
OriginGermany
ModelS-150
Instrument TypeLaboratory
Pump Pressure Range0–40 MPa
Flow Rate Range0.000–10.000 mL/min
Eluent Flow Rate Range0.000–10.000 mL/min
Maximum Operating Pressure35 MPa
Operating Temperature Range5–35 °C
Temperature Reproducibility±0.01 °C
Eluent Concentration RangeApplication-dependent (compatible with common carbonate/bicarbonate, hydroxide, methanesulfonic acid, and other IC eluents)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabomatic
OriginSwitzerland
ModelLHP3000 / LMP3000
Instrument TypeHigh-Pressure Preparative LC System
Pump Flow Range0.2–1640 mL/min
Max Pressure600 bar (HDK-51) to 150 bar (HDK-1640)
Flow StabilityRSD < 0.1%
Piston Stroke3.2–17.1 mm
Piston Frequency0–200 cycles/min
Wetted MaterialsSapphire, Ruby, Zirconia Ceramic, PEEK, 1.4435 Stainless Steel
Power Supply110 / 230 V, 50 / 60 Hz, 1200 VA
Dimensions (Controller)316 × 142 × 400 mm (W × H × D)
Dimensions (Pump Unit)316 × 198 × 400 mm
Interface Options1/4″, 1/8″, 1/16″
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSykam
OriginGermany
ModelS-3580
Refractive Index Range1.00–1.75 RIU
Flow Rate Range0.2–3.0 mL/min (analytical/micro), 1.0–50 mL/min (semi-preparative)
Linear Range0–500, 0–1,000, or 0–20,000 µRIU
Noise Level5×10⁻⁹ to 10×10⁻⁸ RIU
Drift<1 mV/h (at 1.0 mL/min, H₂O)
Cell Volume4 µL, 7 µL, or 9 µL
Cell Angle45° or 5°
Maximum Pressure Rating6 kg/cm²
Dead Volume6 µL, 24 µL, or 88/353 µL
Temperature ControlAmbient, 35–55 °C (1 °C increments)
Response Time Options0 s (real-time), 0.4 s, 0.8 s, 1.2 s
Output±1 V analog
Interface Frequency1 Hz or 10 Hz
Housing Dimensions220 × 350 × 155 mm
Weight~11 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabomatic
OriginSwitzerland
ModelLH3000
Instrument TypeHPLC Autosampler
X-axis Travel Range160–2800 mm (customizable)
Y-axis Travel Range70–670 mm (single arm)
Z-axis Height Range130–780 mm (fixed base height), max vertical stroke: 400 mm
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSykam
OriginGermany
ModelS-3115
Detection PrincipleBipolar Pulsed Electrode Conductivity Measurement
Measuring Range0.05–10,000 µS
Rise Time0–10 s
Cell Volume0.2 µL
Temperature Control RangeAmbient to 85 °C
Temperature Stability±0.01 °C
Signal Offset Adjustment0–20% of full scale
Digital Signal SmoothingEnabled
Auto-zero FunctionSupported
External Control InterfaceAnalog (0–10 V) and RS232
Dimensions330 × 220 × 160 mm
Weight~8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSykam
OriginGermany
ModelS-433D
Instrument TypePost-column Derivatization Amino Acid Analyzer
Pump Flow Rate0.000–9.999 mL/min
Maximum Pump Pressure40 MPa (400 bar, 6000 psi)
Autosampler Injection Volume1–500 µL
Autosampler Temperature Control+4 °C to 70 °C (electronic thermostating)
Post-column Reactor Temperature RangeAmbient to 180 °C (temperature stability ±0.1 °C)
Detection WavelengthsSimultaneous dual-wavelength detection at 570 nm and 440 nm
Flow Cell Volume8 µL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSykam
OriginGermany
ModelS-3210, S-3210S, S-3210DAD, S-3240, S-3240DAD
Wavelength Range190–720 nm
Spectral Bandwidth6 nm (2 nm per diode)
Noise±1.5 × 10⁻⁵ AU
Drift5 × 10⁻⁵ AU/h
Wavelength Accuracy±0.5 nm
Absorbance Range0.0005–2.0 AU (full scale, 8 selectable ranges)
Flow CellPEEK, 10 mm path length, 12 µL volume
Scan Speed0.1 s for full 190–720 nm spectrum
Analog Outputs4 channels (0–1.0 V, full-scale matched to absorbance range)
InterfaceRS232
Detector TypeDiode Array Detector (DAD) or Programmable Single-Channel UV-Vis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSykam
OriginGermany
ModelS-501
Instrument TypeConventional High-Performance Liquid Chromatograph
Flow Rate Range0.001–10.000 mL/min
Maximum Pressure40 MPa
Autosampler Capacity120 positions
Injection Volume Range0.1–999.9 µL
Column Oven Temperature Range4–100 °C
UV/Vis Wavelength Range190–800 nm
Data Acquisition Rate10 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSykam
OriginGermany
ModelS5200
Instrument TypeHPLC Autosampler
Sample Capacity120 vials (2 × 60-position trays)
Standard Loop Volume20 µL (exchangeable)
PrecisionRSD < 0.5% (fixed-volume mode)
Carryover< 0.01% (low-pressure wash)
Programmable Wash ProtocolYes
Control InterfaceAnalog signal or RS-232 digital
Dimensions415 × 300 × 445 mm
Weight~20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabomatic
OriginSwitzerland
TypeDynamic Axial Compression (DAC) System
Construction MaterialBorosilicate Glass
Max Operating Pressure65 bar (940 psi)
Piston Adjustment Range150 mm
Column Diameter Options8 sizes (28–300 mm)
Column Length Options3 standard lengths
Seal DesignSpring-loaded elastomeric seals
Sample DistributionOptimized distributor for improved packing reproducibility
CompatibilityBiocompatible inert materials
Modular Conduit SystemShared tubing manifold for multi-column operation
Packing Tool KitsAvailable for all AMC column diameters
Regulatory ContextDesigned for GLP-compliant preparative chromatography workflows
Show next