| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | DSQ II |
| Mass Spectrometer Type | Single Quadrupole |
| Usage Duration | 3–4 years (Total Service Life: ~7 years) |
| Warranty | 6 months |
| Vacuum System | Dual-stage (Mechanical Pump + High-Performance Turbomolecular Pump) |
| Ion Source | Electron Ionization (EI), DuraBrite™ Design, Max Temp 300 °C |
| Mass Range | 1–1050 amu |
| Scan Speed | Up to 11,000 amu/sec |
| Sensitivity (EI, Full Scan) | ≥200:1 S/N for 1 pg Octafluoronaphthalene (OFN) |
| Resolution | Unit Mass |
| Detector | DynaMax™ EPT Electron Multiplier (Dynamic Linear Range: 10⁸) |
| GC Interface Max Temp | ≥300 °C |
| Software | Xcaliber™ + QuanLab™ Quantitation Suite |
| Compliance | Fully Compatible with ASTM D5845, EPA Methods 8270/8330, USP <621>, and GLP/GMP Data Integrity Requirements (21 CFR Part 11-ready audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Finnigan Surveyor |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | Finnigan Surveyor |
| Instrument Usage Duration | 3 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Finnigan Surveyor Plus |
| Category | Liquid Chromatograph |
| Usage Duration | 3–4 years |
| Warranty | 6 months |
| Compliance | FDA 21 CFR Part 11 (via ChromQuest CDS) |
| Detector Configuration | UV/Vis, Refractive Index, PDA with LightPipe™ technology |
| Pump Type | Quaternary LC pump |
| Integrated Column Oven | Yes |
| Software | ChromQuest Chromatography Data System |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Focus GC |
| Product Category | Chromatography |
| Usage Duration | 4–5 years |
| Warranty Period | 6 months |
| Instrument Model | Focus GC |
| Instrument Age | 4 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Focus |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 6000 |
| Wavelength Range | 166–847 nm |
| Spectral Resolution | 7 pm at 200 nm |
| Detector | High-performance solid-state CID detector (CID86 chip) |
| RF Generator | 27.12 MHz solid-state |
| Optical System | Echelle spectrometer with 52.91 lines/mm ruled grating, 383 mm focal length, UV-grade fused silica cross-disperser prism (9.5°) |
| Nebulization | Concentric glass nebulizer + cyclonic spray chamber + EMT torch assembly (1.5 mm radial / 2.0 mm dual-view quartz center tube) |
| Peristaltic Pump | 4-channel micro-peristaltic pump, 0–125 rpm |
| Dimensions (W×D×H) | 840 × 750 × 590 mm |
| Operational Age | 6–8 years |
| Warranty | 6 months |
| Compliance | ASTM D1976, ISO 11885, USP <232>/<233>, EPA Methods 200.7, 200.8, 6010D |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 6000 |
| Instrument Type | Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) |
| Age | 6–8 years |
| Warranty | 1 year |
| Category | Used Analytical Instrument |
| Regulatory Compliance | Designed to meet ASTM D5193, ISO 11885, USP <232>/<233>, and EPA Methods 200.7, 200.8, and 6010D requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 7000 |
| Product Category | Optical Emission Spectrometer (ICP-OES) |
| Instrument Age | 6–8 years |
| Warranty | 6 months |
| Compliance | ASTM D5185, ISO 11885, USP <232>/<233>, EPA Methods 200.7 & 6010D |
| Detection Limit | Sub-ppb (typical for most elements) |
| Plasma Observation | Radial and Axial |
| Detector | Charge Injection Device (CID) |
| RF Generator | Solid-State, 27.12 MHz |
| Optical System | High-Resolution Simultaneous Monochromator with Precision Temperature Control |
| Sample Introduction | Modular, Auto-Connecting Gas Lines, Interchangeable Nebulizers & Spray Chambers |
| Software Platform | Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 7400 DUO |
| Instrument Age | 9 years |
| Warranty | 1 year |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry |
| Regulatory Compliance | Designed to support ASTM D5185, ISO 11885, USP <232>/<233>, and EPA Methods 200.7, 200.8, and 6010D |
| Software Platform | Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) |
| Dual-View Configuration | Radial and Axial Simultaneous Viewing |
| RF Generator | Solid-State, 27.12 MHz, 1.5 kW |
| Nebulizer | Glass concentric or SeaSpray™ high-salt nebulizer (configurable) |
| Detector | Advanced solid-state CCD array with thermoelectric cooling |
| Resolution | ≤0.007 nm at 200 nm |
| Detection Limits | Sub-ppt to low-ppt range for most elements (e.g., 0.04 ng/mL for Mg II 280.270 nm, axial view) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | IRIS Intrepid II XDL |
| Instrument Type | Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) |
| Age | 4–5 years |
| Warranty | 6 months |
| Configuration | Fully Tested & Refurbished |
| Compliance | ASTM D1976, ISO 11885, USP <232>/<233>, EPA Methods 200.7 & 6010D |
| Software | TEVA™ v4.x (FDA 21 CFR Part 11–ready audit trail enabled) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | IRIS Intrepid II XSP |
| Focal Length | 381 mm |
| Wavelength Range | 165–1050 nm |
| Spectral Resolution | 0.005 nm at 200 nm |
| Stray Light | < 0.3 ppm (measured at As 193.696 nm with 10,000 ppm Ca) |
| RF Generator Frequency | 27.12 MHz |
| Frequency Stability | ±0.004% |
| RF Power Output | 750–1500 W (continuously adjustable) |
| Power Stability | ±0.01% |
| Plasma Observation Mode | Axial (vertical torch) |
| Operating Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned protocols |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISQ LT |
| Price Range | USD 13,500 – 40,500 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Instrument Type | GC-MS |
| Model | ISQ QD |
| Mass Range | 1.2–1100 u |
| Ionization Modes | EI, PCI, NCI, PPINICI |
| Acquisition Speed | High-speed full-scan & SIM alternation |
| Source Design | ExtractaBrite™ with Full Source Removal™ |
| Vacuum Interlock | Yes |
| Software | QuanLab Forms, EnviroLab Forms, ToxLab Forms |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Configuration | Includes TRACE 1300 GC, workstation PC, vacuum pump |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Instrument Type | Ion Trap LC-MS System |
| Model | LCQ Advantage |
| Mass Range | 50–2000 m/z |
| Ionization Sources | ESI and APCI |
| Resolution | Up to 30,000 (FWHM) |
| Scan Speed | 66,000 Da/s |
| MSn Capability | Up to MS³ |
| Detection Sensitivity | 5 pg/μL (for standard compounds) |
| Operational Age | 6–8 years |
| Warranty | 6 months |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling capabilities |
| Software | Xcalibur v2.x compatible, supports method validation, spectral library search, and quantitative workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | LCQ Deca XP |
| Mass Range | m/z 50–2000 |
| MSⁿ Capability | up to 10 stages |
| ESI Source | Electrospray Ionization |
| Sensitivity | 10 pg of reserpine (full-scan, S/N ≥ 10:1) |
| Capillary Temperature | 135–350 °C |
| Spray Voltage | 0–8000 V |
| Sheath Gas Flow | 0–100 arbitrary units |
| Auxiliary Gas Flow | 0–20 arbitrary units |
| DAD Wavelength Range | 190–950 nm |
| Instrument Age | ~4 years |
| Warranty | 6 months |
| Configuration | LC-MS system with autosampler, binary pump, degasser, column oven, DAD detector, and ion trap mass spectrometer |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | LCQ Deca XP Plus |
| Mass Range | m/z 15–4000 (up to 60,000 Da for proteins) |
| Scan Modes | Full Scan, Selected Ion Monitoring (SIM), Accurate Mass Scan, Data-Dependent MS/MS |
| MSⁿ Capability | Up to 10 stages |
| Detection Limit | 10⁻¹⁶ mol |
| Signal-to-Noise Ratio | 50:1 |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Software | Xcalibur, BioWorks, BioMass, ProMass |
| Compliance | Designed to support GLP/GMP-aligned workflows with audit-ready data handling |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCQ Duo |
| Product Category | Mass Spectrometer |
| Usage Duration | 4 Years |
| Warranty Period | 6 Months |
| Instrument Type | LC-MS System (LCQ Duo + Surveyor HPLC) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCQ |
| Product Category | Mass Spectrometer |
| Usage Duration | 4 years |
| Warranty Period | 6 months |
| Instrument Model | LCQ |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTQ FT Ultra |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Mass Spectrometer |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | LTQ FT Ultra |
| Service Life | 4 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Mass Spectrometer |
| Model | LTQ |
| Age | 4 years |
| Warranty | 6 months |
| Configuration | Complete system, fully tested and refurbished |
| Compliance | Meets original factory specifications for performance and safety |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTQ XL |
| Price Range | USD 68,000–136,000 |
| Product Category | Mass Spectrometer |
| Usage Duration | 3–4 years |
| Warranty Period | 6 months |
| Instrument Model | LTQ XL |
| Operational Age | 4 years |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | LTQ-Orbitrap |
| Instrument Type | Hybrid Ion Trap–Orbitrap Mass Spectrometer |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and functionally validated per ISO/IEC 17025-aligned protocols |
| Included Components | LTQ XL ion trap, Orbitrap mass analyzer, PowerVar GPI 2000 power conditioner, Neslab ThermoFlex 900 recirculating chiller, vacuum pumping system |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Evolution 300 |
| Optical Design | Double-beam with Ebert monochromator |
| Light Source | Xenon lamp |
| Detector | Dual photodiode array |
| Spectral Range | 190–1100 nm |
| Spectral Bandwidth | 0.5, 1.0, 1.5, 2.0, 4.0 nm |
| Wavelength Accuracy | ±0.3 nm (typical ±0.1 nm) |
| Wavelength Repeatability | ±0.1 nm (typical ±0.03 nm) |
| Photometric Range | –3 to +6 A |
| Stray Light | <0.0001% T at 220 nm (using NaI) |
| Absorbance Linearity | ±0.002 A (0–2 A), ±0.005 A (2–4 A), ±0.01 A (4–6 A) |
| Baseline Flatness | ±0.0008 A (200–800 nm) |
| Sample Compartment | Motorized 6-position cuvette holder with auto-sensing |
| Compliance | ASTM E275, ISO 6425, USP <857>, FDA 21 CFR Part 11 (with VISIONsecurity), GLP/GMP-ready |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orbitrap Fusion Lumos |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Orbitrap Fusion Tribrid High-Resolution Mass Spectrometer |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Model | Trace 2000 |
| Configuration | Dual Electron Capture Detectors (ECD), Split/Splitless (S/SL) Injector |
| Instrument Type | Gas Chromatograph (GC) |
| Age | 4–5 years |
| Warranty | 6 months |
| Certification | Refurbished & Factory-Tested |
| Compliance | Meets ASTM D3612, EPA Method 8081B/8270, ISO 10380, and USP <621> for residual solvent analysis |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Corona Ultra CAD |
| Detection Principle | Charged Aerosol Detection (CAD) |
| Power Supply | 100–240 V AC, 100 VA |
| Serial Number | DU-0136 |
| Age | 3–5 years |
| Warranty | 6 months |
| Compliance | Designed for GLP/GMP-compliant laboratories |
| Software Compatibility | Compatible with Chromeleon CDS (v7.2+), Empower (v3+), and other industry-standard chromatography data systems |
| Regulatory Alignment | Supports 21 CFR Part 11 audit trail requirements when paired with validated CDS configurations |
| Sample Compatibility | Non-volatile and semi-volatile analytes across small molecules to macromolecules |
| Brand | Thermo Fisher Scientific Dionex |
|---|---|
| Origin | USA |
| Instrument Model | ICS-900 |
| Year of Manufacture / Service Life | ~2019–2020 (3–4 years operational use) |
| Warranty | 6 months limited hardware warranty |
| Regulatory Compliance | Fully compliant with ASTM D4327, ISO 14911, USP <645>, and EPA Methods 300.0, 300.1, 310.1 |
| Software Platform | Chromeleon 7.2.10 or later (licensed, validated for GLP/GMP environments) |
| Detector Type | Digital conductivity detector with temperature-compensated cell |
| Pump System | Dual-piston isocratic pump (flow range: 0.001–5.000 mL/min, pressure rating: up to 35 MPa) |
| Suppressor Compatibility | MMS™ 300 (DCR mode) and ERS™ 500 series electrolytic suppressors |
| Fluidic Path | All-PEEK, metal-free, chemical-resistant (pH 0–14, compatible with organic modifiers up to 40% ACN/MeOH) |
| Data Interface | USB 2.0 (supports audit trail, electronic signatures per 21 CFR Part 11) |
| Certification Status | Delivered with full IQ/OQ documentation (performed by SpectraLab Scientific prior to resale) |
| Automation Ready | Compatible with AS-DV autosampler (optional, not included unless specified) |
| Brand | Thermo Fisher Scientific (formerly Dionex) |
|---|---|
| Origin | USA |
| Model | ICS-2100 |
| Instrument Type | Ion Chromatograph |
| Configuration | RFIC-EG + RFIC-ESP Enabled |
| Column Options | 2 mm & 4 mm ID |
| Detector | Digital Conductivity Detector with Temperature Compensation |
| Pump | Dual-piston High-Pressure Isocratic Pump (RFIC-EG Compatible) |
| Flow Rate Precision | ≤0.1% RSD |
| Conductivity Cell | Digital Thermostatted, Low-Dead-Volume |
| Software | Chromeleon 7.2 or Later (FDA 21 CFR Part 11 Compliant) |
| Operating Environment | Lab-grade Cleanroom-Tested |
| Reconditioning Standard | SpectraLab Certified Refurbishment Protocol (ASTM E2500-Aligned) |
| Warranty | 6 Months Limited Hardware Warranty |
| Service History | <4 Years Operational Use |
| Compliance | ISO/IEC 17025 Traceable Performance Verification |
| Connectivity | USB 2.0, Ethernet, Digital I/O |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | XSeries II ICP-MS (Refurbished) |
| Mass Range | 2–260 amu |
| Sensitivity (Li-7) | 50 Mcps/ppm |
| Sensitivity (Y-89) | 60 Mcps/ppm (XSeries II standard configuration) |
| Sensitivity (Tl-205) | 80 Mcps/ppm |
| Detection Limit (Be-9) | 0.5 ppt |
| Detection Limit (In-115, Bi-209) | 0.1 ppt |
| Oxide Ratio (CeO+/Ce+) | ≤1.5% |
| Doubly Charged Ion Ratio (Ce2+/Ce+) | ≤3.0% |
| Isotopic Ratio Precision (107Ag/109Ag) | RSD ≤0.1% |
| Abundance Sensitivity (low-mass) | 5 × 10⁻⁷ |
| Abundance Sensitivity (high-mass) | 1 × 10⁻⁷ |
| Collision Cell | ORS3™ (He-only mode) |
| High Matrix Tolerance | Up to 3% total dissolved solids (TDS) via HMI technology |
| Software Platform | MassHunter Workstation (QA/QC, audit trail, automated method execution) |