| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010A (Red-Black Label) |
| Category | Imported Used Analytical Instrument |
| Distribution Type | Authorized Distributor |
| Price Range | USD 6,800 – 19,000 (FOB Asia) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010AF |
| Detector | FID (Flame Ionization Detector) |
| Injector | SPL Split/Splitless Injector with AFC (Advanced Flow Control) |
| Software | LabSolutions (Bilingual: English/Chinese) |
| Operational Age | 4–5 years (Total Service Life: ~7 years) |
| Warranty | 6 months |
| Compliance | Designed to meet ISO/IEC 17025-aligned operational standards for routine QC labs |
| Temperature Range | Oven: 4–450 °C |
| Injector & Detector | up to 450 °C |
| Cooling Rate | Intelligent back-door cooling enabling near-ambient operation (~10 °C above ambient) |
| Data System | PC-based LabSolutions with audit trail-capable acquisition and reporting modules |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010Plus |
| Configuration | Multi-detector, Dual Autosampler (AOC-20i ×2 + AOC-20s) |
| Column Oven Temp Range | Ambient +4°C to 450°C (down to –50°C with liquid CO₂ cooling option) |
| Cooling Rate | 450°C → 50°C in ≈3.4 min |
| Detector Options | FID (1.5 pgC/s), ECD (6 fg/s), FPD (P: 55 fgP/s |
| S | 3 pgS/s), TCD, FTD/NPD |
| AFC Pressure Control | 0–970 kPa, 7-segment programming |
| Max Simultaneous Detectors | 4 |
| Max Simultaneous Inlet Units | 3 |
| Display | 240 × 320 dot graphic LCD |
| Brand | Shimadzu |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GC-2014 |
| Price Range | USD 6,800 – 13,600 |
| Product Category | Chromatography System |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Configuration | Split/Splitless Injector (SPL), Dual-Detector Setup (SCD + PID) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2014 |
| Category | Gas Chromatograph |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Regulatory Compliance | CE-marked, compliant with ISO/IEC 17025 laboratory practices for used instrument validation |
| Software Platform | Shimadzu GCsolution (v2.8 or later, license included) |
| Detector Configuration | FID-2014 (standard), SPL-2014 inlet, PC-based workstation |
| Carrier Gas Control | Electronic Flow Control (AFC) for both capillary and packed columns |
| Operating Temperature Range | Oven: 4–450 °C |
| Inlet & Detector | up to 450 °C |
| Data Integrity | Audit trail enabled, compliant with FDA 21 CFR Part 11 requirements when configured with GCsolution’s secure user management |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2014A |
| Column Oven Temp Range | Ambient +10 °C to 420 °C (–50 °C to 420 °C with liquid CO₂ cooling) |
| Injector Temp Range | Up to 420 °C |
| Detector Temp Range | Up to 420 °C (FID/TCD/FTD), up to 400 °C (ECD/FPD) |
| Max Simultaneous Inlets | 3 |
| Max Simultaneous Detectors | 4 |
| Programmed Temperature Ramping | 20-step, –250 to +250 °C/min |
| Pressure Control | Digital AFC (0–970 kPa, ramp rate –400 to +400 kPa/min) |
| Display | 240 × 320-pixel graphical LCD |
| Dimensions (W×H×D) | 607 × 690 × 400 mm |
| Weight | 48 kg (GC-2014AF configuration) |
| Power Supply | AC 200 V, 1800 VA, 50/60 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Model | GCMS QP-5000 |
| Gas Chromatograph Component | GC-17A |
| System Age | 4 years |
| Warranty | 6 months |
| Configuration | Complete benchtop GC-MS system with control PC, acquisition software, and all essential hardware (capillary columns, transfer lines, ion source components, vacuum system) |
| Compliance Status | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocols |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010 Plus |
| Mass Range | m/z 10–1090 |
| Scan Speed | 10,000 amu/sec |
| Vacuum System | Dual-inlet turbo molecular pump (≥360 L/s) |
| Ion Source | Shielded design with uniform temperature distribution |
| Detection Mode | Scan/SIM simultaneous acquisition via FASST |
| Mass Analyzer | Molybdenum quadrupole with pre-rod |
| Retention Time Correction | AART (Automatic Adjustment of Retention Time) |
| Software | Compound Composer, Method Package, EPA-compliant modules, GPC-GC/MS integration capability (Prep-Q system) |
| Warranty | 1 year |
| Instrument Age | 3–5 years |
| Compliance | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010 Plus |
| Configuration | GC-2010 Plus GC, TD-20 Thermal Desorber, AOC-20s 100-position Autosampler Tray, AOC-20i Autosampler, LabSolutions Software Workstation, Dual-inlet Turbo Molecular Pump (≥360 L/s), Vacuum System |
| Warranty | 90 days post-installation verification |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | QP2010 Plus |
| Instrument Type | Benchtop GC-MS |
| Configuration | Single Quadrupole |
| Detection Mode | Electron Ionization (EI) |
| Mass Range | 1.5–1099 u |
| Scan Speed | Up to 10,000 u/sec |
| Interface Temperature | Up to 300 °C |
| Ion Source | Dual-mode (EI/CI optional with upgrade) |
| Vacuum System | Turbomolecular pump + backing pump |
| Compliance | Fully compatible with ASTM D5845, EPA Method 8270/8260, USP <621>, ISO 17025 workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Canada |
| Instrument Model | GCMS-QP2010 Ultra |
| Mass Spectrometer Type | Quadrupole GC-MS |
| Age | 3–4 years |
| Warranty | 6 months |
| Configuration | GC-2010 Plus GC + QP2010 Ultra MS + AOC-5000A/AOC-5000 Plus Autosampler (optional) + Turbo Molecular Pump + Dedicated PC with GCMSsolution Software |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned internal protocols |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | QP2010 Ultra |
| Price | USD 27,500 (approx.) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Configuration | GC-2010 Gas Chromatograph + QP2010 Mass Spectrometer + AOC-20i Auto-sampler + AOC-20s 100-position Tray + Capillary Inlet + Vacuum Pump + LabSolutions Software Workstation |
| Operational Age | 7 years |
| Power Consumption Reduction (Standby) | 36% |
| CO₂ Emission Reduction | 30% |
| Scan Speed | 20,000 u/sec |
| Warranty | 90-day limited hardware warranty |
| Compliance | ASTM D5845, ISO 17025-compatible operation environment, USP <1225> method validation support |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | QP2010 |
| Configuration | VOC/SVOC Analysis-Optimized (per GB/T 23986.2–2023) |
| Regulatory Alignment | Compliant with ISO 11843, ASTM D6886, and US EPA Method TO-17 for VOC quantification |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010Plus |
| Condition | Refurbished & Fully Qualified |
| Compliance | Meets Original Shimadzu Factory Specifications |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010S |
| Mass Spectrometer Type | Single Quadrupole |
| Scan Speed | Up to 10,000 u/sec |
| Ion Source | Front-Opening EI/CI Dual-Mode Ion Source |
| Autosampler | AOC-20i with 100-Position Tray (AOC-20s) |
| Gas Chromatograph | GC-2010 |
| Software | LabSolutions GCMS (vX.X, compliant with FDA 21 CFR Part 11 audit trail requirements) |
| Operational Age | 3–4 years (Total Service Life: ~7 years) |
| Warranty | 6 months limited hardware warranty |
| Vacuum System | Integrated turbomolecular pump assembly |
| Sample Introduction Options | Capillary inlet, Direct Insertion Probe (DIP), SPME, Headspace, Purge-and-Trap, Pyrolysis (PY-GCMS-ready) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010SE |
| Configuration | GC-2010 Plus GC + QP2010SE MS + Auto-sampler (Headspace or Liquid, selectable) + Vacuum Pump + LabSolutions Workstation PC + Essential Tubing/Cabling |
| Warranty | 90-day comprehensive hardware warranty |
| Condition | Fully tested and verified operational status |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP5050A |
| Instrument Type | Quadrupole Mass Spectrometer (GC-MS) |
| Gas Chromatograph | GC-17A |
| Age | 4 years |
| Warranty | 6 months |
| Compliance | Designed to meet ISO/IEC 17025-aligned operational standards for routine QC and research environments |
| Software Platform | Original Shimadzu CLASS-5000 (MS) v3.x or later |
| Detection Principle | Electron Ionization (EI) with unit-mass resolution, full-scan and selected-ion monitoring (SIM) modes |
| Key Performance Context | Engineered for reproducible trace-level organic compound identification and quantification in environmental, pharmaceutical, and food safety laboratories |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8040 |
| Configuration | Refurbished Unit with Full Functional Validation |
| Compliance | Meets Original Shimadzu Factory Specifications for GC-MS/MS Operation |
| Software | Includes Licensed GCMSsolution Ver. 5.x (with Smart MRM, ASSP, and Scan/MRM Simultaneous Acquisition Modules) |
| Instrument Status | Fully Recertified with Performance Verification Report (PVR) per ISO/IEC 17025 Traceable Protocols |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8050 |
| Year of Manufacture | 2018 |
| Condition | Refurbished & Certified Pre-Owned |
| Configuration | Complete Benchtop System with GC, TQMS, Autosampler, and GCMS Insight Software |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | HS-20 / HS-20LT / HS-20 TRAP (90-position) |
| Configuration | Quantitative Loop or Cold Trap Mode |
| Sample Capacity | 90 vials (20 mL standard) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | ICPE-9000 |
| Wavelength Range | 167–800 nm |
| Optical System | Echelle spectrometer with vacuum UV capability |
| Detector | 1-inch CCD (1 MPixel) |
| RF Generator | Crystal-oscillator-based, 27.12 MHz |
| Plasma Torch | Vertical orientation, micro-torch standard (standard torch optional) |
| Viewing Direction | Axial and radial viewing (switchable, optional) |
| Nebulizer | Concentric type |
| Spray Chamber | Cyclonic spray chamber |
| Spectrometer Environment | Vacuum optical chamber |
| Temperature Control Stability | ±0.1 °C |
| Argon Consumption | Reduced by ~50% vs. conventional torches |
| Software Features | Automatic wavelength selection, coexisting element library generation, qualitative & quantitative analysis, full-spectrum data archiving |
| Warranty | 12 months post-commissioning |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | L-3530 |
| Detection Principle | Evaporative Light Scattering |
| Light Source | High-Efficiency LED (470 nm) |
| Detector | High-Sensitivity Photomultiplier Tube (PMT) |
| Evaporation Temperature Range | Ambient to 100 °C (1 °C increments) |
| Flow Rate Compatibility | 0.1–2.5 mL/min (standard) |
| Nebulizing Gas | Nitrogen or compressed air (≥5 L/min, 2–4.5 bar) |
| Gas Consumption | <3.0 L/min |
| Baseline Noise | <1×10⁻³ AU/hr (aqueous) / <3×10⁻³ AU/hr (non-aqueous) |
| Detection Limit | <5 ng (caffeine) |
| Quantitation Range | 0.5–5 µg |
| Dimensions | 550 × 250 × 480 mm (D×W×H) |
| Power Supply | 115 V AC, 60 Hz, 1.8 A or 230 V AC, 50 Hz, 1.7 A |
| Age | 3–4 years |
| Warranty | 2 years |
| Category | Spectroscopic Detector for HPLC Systems |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Detector Types | Photodiode Array (PDA), Refractive Index (RID), Fluorescence (FLD) |
| Series Compatibility | LC-10AT/10AVP, LC-20AT/20AP |
| Condition | Factory-Refurbished with Full Functional Validation |
| Certification | ISO/IEC 17025–Aligned Calibration Report Available |
| Warranty | 12-month limited hardware warranty |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-10A |
| Instrument Category | Chromatography |
| Age | 2–3 years |
| Warranty | 6 months |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Price Range | USD 2,800 – 4,900 (FOB China) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-10ATvp |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 40 MPa |
| Flow Precision | ≤0.1% RSD |
| Gradient Accuracy | ±1% (0–100%, water/acetone binary gradient) |
| UV-Vis Detector | SPD-10AVP Plus |
| Wavelength Range | 190–600 nm (SPD-10Avp), 190–900 nm (SPD-10AVvp) |
| Spectral Bandwidth | 8 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Baseline Drift | ≤2×10⁻⁴ AU/h (250 nm, ambient temperature stable) |
| Noise Level | ≤0.35×10⁻⁵ AU (2 sec time constant, 250 nm) |
| Flow Cell | 10 mm path length, 8 µL volume, 12 MPa max pressure |
| Dimensions (Pump) | W260 × H140 × D420 mm, 11 kg |
| Dimensions (Detector) | W260 × H140 × D420 mm, 13 kg |
| Operating Temperature | 4–35 °C |
| Service History | <2 years in operation |
| Warranty | 6 months post-installation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2010A HT |
| Configuration | Integrated HPLC System (No Column Oven Cooler) |
| Instrument Age | 4–7 years |
| Warranty | 6 months |
| Compliance | Designed to meet ISO/IEC 17025-aligned operational standards for routine QC/QA labs |
| Software | Shimadzu Class VP v7.x (pre-installed on included PC) |
| Flow Accuracy | ≤ ±0.1% RSD |
| Gradient Accuracy | ≤ ±0.2% absolute |
| Injection Precision | ≤ 0.3% RSD (10 µL, n=6) |
| UV-Vis Detector Noise | ≤ ±2.5 × 10⁻⁶ AU (254 nm, 1 s time constant) |
| Baseline Drift | ≤ 1 × 10⁻⁴ AU/h |
| Linear Range | 2.5 AU |
| Column Oven Temp Range | 4–80 °C (Peltier-based, dual-zone control) |
| Autosampler Capacity | 350 × 1.5 mL vials or up to 4 × 96-well microplates |
| Degasser | 5-channel membrane degassing unit with integrated solvent line deaeration |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2010AHT |
| Configuration | Integrated HPLC System with Solvent Degasser, Low-Pressure Gradient Unit, Dual-Piston Pump, Autosampler with Refrigerated Sample Cooler, Column Oven, and UV-Vis Detector |
| Flow Rate Range | 0.001–5.0 mL/min (up to 35 MPa) |
| Gradient Accuracy | ±0.5% (binary system) |
| Autosampler Capacity | Up to 350 × 1 mL vials |
| Detection Wavelength Range | 190–600 nm |
| Temperature Control Range (Column Oven) | 15 °C below ambient to 60 °C |
| Warranty | 6 months |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2010C HT |
| Configuration | Integrated HPLC System with Peltier Cooled Autosampler |
| Pump Type | Micro-stroke Dual Plunger |
| Flow Accuracy | ≤ ±0.1% RSD |
| Gradient Accuracy | ≤ ±0.2% |
| Injection Precision | ≤ 0.3% RSD (n=6) |
| Injection Speed | 15 s (10 µL) |
| Sample Capacity | 350 × 1.5 mL vials or up to 4 microtiter plates |
| Column Oven Temperature Range | 4–85 °C (Peltier-based heating/cooling) |
| UV-Vis Detector Noise | ≤ ±2.5 × 10⁻⁶ AU (254 nm, 1 s response) |
| Linearity | 2.5 AU |
| Detector Cell Temperature Control | Yes (thermostatted flow cell) |
| Degasser | 5-channel membrane degasser with integrated wash solvent degassing |
| Warranty | 6 months limited hardware warranty |
| Service History | Fully refurbished and performance-verified by SpectraLab Scientific |
| Operational Age | 7 years |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | LC-2010CHT |
| Pump | Serial dual-plunger micro-pump (10 µL primary, 5 µL secondary) |
| Flow rate range | 0.001–5.0 mL/min (at 1.0–35.0 MPa) |
| Flow precision | ≤0.075% RSD (0.05–2.0 mL/min, methanol, 20 °C) |
| Low-pressure gradient elution | Up to 4 solvents, 0.1% increment |
| Autosampler injection volume | 0.1–100 µL |
| Injection repeatability | ≤0.3% RSD (10 µL) |
| Column oven temp. range | (ambient −15) to 60 °C, stability ±0.1 °C |
| UV-Vis detector | Deuterium lamp, 190–600 nm, wavelength accuracy ±1 nm, wavelength reproducibility ±0.1 nm, drift ≤1×10⁻⁴ AU/h (250 nm), S/N ≥0.25×10⁻⁵ AU (1 s response, air cell) |
| Dimensions (W×D×H) | 430 × 500 × 605 mm |
| Weight | 52 kg |