- All
- Favorite
- Popular
- Most rated
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-ZXLS |
| Instrument Type | Online |
| Functionality | Multi-parameter (moisture & temperature) |
| Measurement Principle | Resistive |
| Measurable Grains | Corn, Wheat, Soybean, Japonica Rice, Indica Rice, Paddy Rice, Barley, Sorghum, Rapeseed |
| Moisture Range | 11.0–40.0 % w.b. |
| Moisture Resolution | 0.1 % |
| Moisture Accuracy | ±0.5 % (within 10–20 % range) |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1 °C |
| Display | 4.3-inch Chinese-language capacitive touchscreen |
| Operating Ambient | −30 to 100 °C (non-condensing) |
| Power Supply | AC 220 V |
| Host Dimensions | 210 × 260 × 95 mm |
| Sensor Dimensions | 282 × 180 × 160 mm |
| Protection Design | Sealed enclosure for dust and moisture resistance |
| Motor Protection | Overcurrent, open-circuit, and foreign-object (e.g., stone) detection |
| Sampling Cycle | Real-time countdown display |
| Calibration Flexibility | Adjustable roller gap for multi-grain compatibility |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-ZW216 |
| Detection Principle | Real-Time Fluorescent Quantitative PCR (qPCR) |
| Channel Configuration | Dual-channel (FAM/VIC compatible) |
| Sample Capacity | 16 × 0.2 mL wells (supports single tubes & 8-tube strips) |
| Temperature Range | 4–99 °C |
| Thermal Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ≤±0.25 °C |
| Max Heating/Cooling Rate | 6 °C/s / 4 °C/s |
| Optical System | Dual high-intensity LED excitation sources (460–480 nm & 525–545 nm), dual photodiode detectors with narrow-band interference filters |
| Sensitivity | Single-copy DNA detection capability |
| Dynamic Range | 10 orders of magnitude (1–10¹⁰ copies/µL) |
| Linearity | R² ≥ 0.999 |
| Reproducibility | CV < 2% (fluorescence), CV < 2% (sample), CV < 3% (precision) |
| Data Output Formats | PDF, XLS, CSV, DOCX |
| Connectivity | USB 2.0, Wi-Fi (optional), Android-based onboard OS |
| Dimensions | 350 × 384 × 184.5 mm |
| Weight | 5.4 kg |
| Power | 220 V AC, max 300 W |
| Operating Environment | 18–35 °C, 0–85% RH (non-condensing) |
| Brand | Tianyan |
|---|---|
| Model | TY-HRD |
| Origin | Shandong, China |
| Temperature Range | 0–1600 °C (±3 °C accuracy) |
| Resolution | 1 °C (temperature), 1 min (time |
| Heating Rate | 15–20 °C/min up to 900 °C |
| Thermocouple Type | S-type (Platinum-Rhodium/Platinum) |
| Max Control Current | 30 A |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 10 W |
| Dimensions (W×H×D) | 305×390×120 mm |
| Operating Environment | 0–40 °C, RH ≤80% |
| Communication Interface | RS232 |
| Compliance | GB/T 219–2008 (Chinese National Standard for Coal Ash Fusibility) |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TY-SuperVario-N |
| Speed Range | 600–1130 rpm |
| Temperature Control Range | Ambient to 68 °C |
| Power Supply | 230 V / 50 Hz |
| Internal Chamber Height | 370 mm |
| Overall Height | 460 mm |
| Net Weight | 26 kg |
| Brand | Tianyan |
|---|---|
| Model | TY-FK100 / FK200 / FK300 / FK400 / FK500 |
| Origin | Shandong, China |
| Power Supply | 220 V AC, 50 Hz |
| Max. Power | 500 W |
| Sealing Speed | 10 m/min |
| Sealing Width | 12 mm |
| Temperature Range | 60–220 °C (±1% control accuracy) |
| Sealing Margin Adjustment | 0–35 mm |
| Display | 7-inch color touchscreen (GUI, bilingual Chinese/English, text-to-speech support) |
| Print Capability | Dual-line dot-matrix printing (reversible 180°), customizable font width, selective field suppression, intelligent bag-width matching logic |
| Data Storage | >10 million records |
| Compliance | YY/T 0698.5–2009 (seal strength), YY 0466–2003 (medical device symbols) |
| Enclosure Options | Powder-coated carbon steel or 304 stainless steel |
| Dimensions | 620 × 270 × 220 mm |
| Weight | 20 kg |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-FSX |
| Detection Range | 1 µm – 10 mm |
| Imaging Resolution | 2592 × 1944 (5 MP CMOS camera) |
| Optical Magnification | 100× |
| Image Size Options | 640×480, 1024×768, 2048×1536, 2592×1944 |
| Power Supply | 220 V / 2 A / 50 Hz |
| Compliance | GB/T 6030–2006 |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Model | TY-CHY |
| Measurement Range | 0–5 mm (customizable fixtures available) |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 50 ± 1 kPa (for paper) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Class of Accuracy | Grade 0.5 |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions | 450 × 340 × 390 mm |
| Weight | 30 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 6672-2001, GB/T 451.3-2002, GB/T 6547-1998, ISO 4593:1993, ISO 534:2011, ISO 3034:2011, ASTM D374-1999, ASTM D1777-1996 (2007), JIS K6250-1997, JIS K6783-1994, JIS Z1702-1994, BS 3983-1989, BS 4817, TAPPI T411 |
| Interface | RS232 serial port |
| Optional Accessories | Auto-sampler unit, PC-based analysis software, calibration weights, communication cable |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-SSY-24F |
| Maximum Pressure | 0–24 metric tons (235.2 kN) |
| Piston Diameter | φ95 mm |
| Max Piston Stroke | 30 mm |
| Pressure Display Resolution | 0.01 MPa (equivalent to 0.102 ton-force) |
| Pressure Stability | ≤1 MPa per 10 minutes |
| Worktable Diameter | Φ105 mm |
| Column Spacing | 112 × 160 mm |
| Overall Dimensions | 305 × 200 × 440 mm (L×W×H) |
| Net Weight | 65 kg |
| Protective Shield | Transparent Acrylic |
| Structural Design | Monolithic Mainframe (integrated oil reservoir, baseplate, and chrome-plated cylinder |
| Hydraulic System | Filtered oil circuit, custom piston seal, extended-life tension spring (30 mm stroke retention), aluminum alloy handwheel |
Show next