Empowering Scientific Discovery

Shanghai Bang'an Testing Engineering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSBS
OriginUSA
Instrument TypePortable
Measurement PrincipleFalling-Pin Viscometry
Viscosity Range5–10⁶ cP
Sample Volume4.5 mL
Accuracy±3% (PDV-100)
Repeatability±3%
Operating EnvironmentAmbient Temperature
ComplianceASTM D7483, ISO 12058-1 (for falling-body viscometry), GLP-ready workflow support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCCS-2100F
Instrument TypeRotational Viscometer (Cold Cranking Simulator)
Temperature Range−35 °C to −5 °C
Temperature Resolution & Accuracy±0.05 °C
Apparent Viscosity Range1,500–27,000 mPa·s
ComplianceASTM D5293, SAE J300-99, GB/T 6538
Cooling MethodSolid-State Thermoelectric (No Refrigerants)
Sample Throughput30 Samples per Unattended Run
Control SystemWindows-Based PC with CCS-RA Interface and LIMS-Ready Software
Power Supply230 V / 50 Hz / 1000 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSBS
OriginUSA
Instrument TypePortable Falling-Pin Viscometer
Sample TubeDisposable 4.5 mL glass tube
Measurement PrincipleGravitational falling-pin (Stokes’ law-based)
Viscosity Range1–10⁸ cP
Temperature Control Range0–100 °C
Timing Resolution0.001 s
Pin Density Range6–300 g/cm³
Accuracy & Repeatability<1%
InterfaceRS232
ComplianceASTM D1200, ISO 2555, USP <911> (for kinematic viscosity correlation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCAV4.1
Instrument TypeCapillary Viscometer (Fixed Benchtop)
Kinematic Viscosity Range0.5–10,000 mm²/s (cSt)
Temperature Range20–150 °C
Temperature Resolution & Accuracy±0.01 °C
ComplianceASTM D445, ASTM D446, ISO 3104, ISO 3105, IP 71, GB/T 265
Sample ThroughputDual-capillary parallel measurement
Integrated ControlBuilt-in industrial PC + 10.4″ color touchscreen
SoftwareVISCPRO (supports up to 4 CAV4.1 units per host PC)
Cleaning & DryingAutomated solvent rinse and compressed-air drying
Capillary ExchangeTool-free, bath-oil–retaining design
CalibrationSingle-point temperature calibration per capillary
Status IndicationMulti-color LED status lighting
Power Supply100–240 VAC, 50/60 Hz
CertificationsCE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelminiAV
Instrument TypeCapillary Viscometer (Fixed-Station, Benchtop)
Viscosity Range0.5–10,000 mm²/s (cSt)
Temperature Range15–100 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C (at setpoint)
ComplianceASTM D445, ASTM D446, ISO 3104, ISO 3105
Sample Volume5–10 mL per test
Bath Volume1 L
Dimensions254 mm (W) × 533 mm (H) × 381 mm (D)
ConnectivityRS-232
SoftwareVISCPRO II (Windows 98/NT/XP compatible)
Multi-unit ControlUp to 4 units per PC
LIMS IntegrationYes
Operating Humidity10–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCMRV-4500F
Instrument TypeRotational Viscometer (Fixed-Mount)
Temperature Range–5 °C to –40 °C
Temperature Resolution±0.1 °C
Temperature Accuracy±0.1 °C
Cooling MethodThermoelectric (Peltier) with Fluorine-Free Coolant Circulation
ComplianceASTM D3829, D4684, D6896, D6821, SAE J300, GB/T 9171, SH/T 0562
Software PlatformWindows 98/NT/XP Compatible Control System
Optional AccessoryDedicated Rotor Kit for ASTM D6821
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSBS
OriginUSA
Manufacturer TypeAuthorized Distributor
Instrument CategoryImported
ModelAuto-Falling Needle
Instrument TypeBenchtop Fixed-Position Viscometer
Operating EnvironmentAmbient Temperature
Viscosity Range0.5–1,000,000 cP
Measurement PrincipleGravitational Sedimentation of Calibrated Needle in Fluid
Shear Rate Range10⁻⁴–10³ s⁻¹
Temperature Range−40 to +150 °C
Sample Volume Options2.3, 3.6, 7.2, 9.6, 19.2, or 120 cm³
Needle MaterialsBorosilicate Glass, Fused Quartz, or Stainless Steel
Standard Needle Length10.2 cm (compact version: 4.2 cm)
Needle Density Options1.01, 1.1, 1.5, 2.0, 3.0, 5.0, and 8.0 g/cm³
Timing Resolution0.01 s (optional 0.001 s)
InterfaceRS-232 Serial Port
Accuracy & Repeatability< ±1%
ComplianceASTM D1545, ISO 12058-1, USP <911>, GLP-Compatible Data Logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelTE-1500F / TE-3000F
Instrument TypeFixed-Position Capillary Viscometer
Operating EnvironmentAmbient Laboratory
Temperature Range–30 °C to +10 °C (TE-1500F) / –30 °C to +30 °C (TE-3000F)
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
ComplianceASTM D445, ISO 3104, GB/T 265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCCS-2100LT
Instrument TypeRotational Viscometer (Fixed-Base, Cold-Bath Configuration)
Temperature Range−5 °C to −40 °C
Temperature Resolution & Accuracy±0.05 °C
Apparent Viscosity Range1500 mPa·s to 21000 mPa·s
Cooling MethodSolid-State Thermoelectric (Peltier)
ComplianceASTM D5293, SAE J300-99, GB/T 6538
Sample ThroughputUp to 30 samples per automated sequence
Control & Data HandlingPC-based automation with self-calibration routines and integrated wash cycle with programmable heating profile
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCCS2100-G6
Instrument TypeRotational Viscometer (Fixed-Base, Low-Temperature CCS)
Temperature Range−40 °C to −5 °C
Temperature Accuracy±0.05 °C
Temperature Resolution±0.05 °C
Viscosity Range900–25,000 mPa·s (cP)
ComplianceASTM D5293, SAE J300, GB/T 6538
Sample Capacity14 samples (unattended)
Cleaning MethodSolvent-Free In-Situ Sample Flush
CalibrationAuto-Rotational Speed Calibration & User-Verifiable Temperature Calibration
SoftwareFlowHub™ Data Management Platform
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelPolyVISC
Instrument TypeCapillary Viscometer
Temperature Range20–100 °C (optional 135 °C)
Temperature Stability±0.01 °C
Efflux Time Resolution±0.01 s
Viscosity Range0.3–20,000 cSt
Solvent CompatibilityBroad (including chlorinated, phenolic, and high-boiling solvents)
ComplianceASTM D2857, ASTM D4603, ISO 307, USP <911>, FDA 21 CFR Part 11 (audit trail enabled in VISCPRO)
Added to wishlistRemoved from wishlist 0
Add to compare
Branderalytics
OriginAustria
ModelERAVISC X
Instrument TypePortable
Measurement PrincipleOscillating U-tube (density) + Dynamic Capillary Flow (kinematic viscosity)
Viscosity Range1–1000 mm²/s
Density Range0–3 g/cm³
Temperature Range15 °C to 100 °C
Heating/Cooling Rate±20 °C/min
Standards ComplianceASTM D445, D7042, D4052, D5002
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelDVR-1000
Instrument TypeFixed-Position Vacuum Viscometer
Operating Temperature Range0–40 °C
Vacuum Accuracy±0.5 mmHg at 300 mmHg setpoint
ComplianceASTM D2171
DisplayDigital LED
Control InterfaceFront-panel membrane keypad
Sensing ElementSolid-state pressure transducer (mercury-free)
Application FocusBitumen and asphalt viscosity testing under controlled vacuum
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCannon
OriginUSA
ModelTESC
Instrument TypeRotational Viscometer (Fixed-Base, Benchtop)
Viscosity Range0.1–10,000 mPa·s
Temperature Range−40 °C to +90 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.1 °C
ComplianceASTM D2983, GB/T 11145
Cooling MethodSolid-State Thermoelectric (Peltier)
Rotor AdjustmentMotorized, Tool-Free
FootprintCompact, Multi-Unit Stackable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCannon
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelTE-BBR
Instrument TypeBending Beam Rheometer
Bearing TypeAir-bearing
Minimum Oscillation Frequency0.1 Hz
Frequency Range0.1–100 Hz
Maximum Oscillation Frequency100 Hz
Maximum Applied Load45 g (0.441 N)
Load Resolution0.015 g (0.147 mN)
Displacement Resolution0.155 µm
Temperature Control Stability±0.03 °C
Minimum Operating Temperature–36 °C
Cooling MethodThermoelectric (Peltier) with Air/Water Heat Exchange
InterfaceRS-232 Serial
Software PlatformWindows 95/NT (v3.51 or later)
System RequirementsIBM-compatible PC, SVGA monitor, 16 MB RAM, 20 MB free HDD space, 1.44 MB floppy drive
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelminiPV-HX
Instrument TypeCapillary Viscometer (Ubbelohde-type, modified)
MountingBenchtop Fixed System
Operating EnvironmentAmbient Temperature
Viscosity Range0.3–1,200 mm²/s (cSt)
Temperature Range15–100 °C
Temperature Resolution0.001 °C
Temperature Accuracy±0.01 °C
Flow Time Resolution0.01 s
Sample Volume~15 mL
Sample Capacity10-position autosampler
CleaningDual-solvent rinse + compressed-air drying
Thermal ControlPeltier-based cooling/heating (no external chiller required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCT-2000
Temperature Control Range20 °C to 150 °C
Temperature Stability±0.01 °C
ComplianceASTM D445, ISO 3104
Communication InterfacesRS-232, RS-485
Bath Capacity7 × 51 mm viscometer ports + 2 auxiliary thermometer ports
Display4-line LCD with digital setpoint & actual temperature readout
Input MethodKeypad entry of two-digit decimal setpoints
Temperature Unit Toggle°C / °F
Self-Diagnostic FunctionPower-on system check
Calibration Offset EntryManual mercury thermometer correction via keypad
Cooling OptionExternal tap water or chiller connection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelHTHS-II
Instrument TypeCapillary Viscometer
Standards ComplianceASTM D5481, SAE J300, SH/T 0703-2001
Operating Temperature150 °C
Shear Rate1.4 × 10⁶ s⁻¹
Sample Throughput15–20 samples/hour
Safety FeaturesInlet valve interlock, overtemperature cutoff
SoftwareWindows-based HTHS viscosity calculation software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelCAV4.2
Instrument TypeFixed-Position Capillary Viscometer
Viscosity Range0.5–10,000 cSt
Temperature Range15–150 °C
Temperature Resolution±0.01 °C
Temperature Accuracy±0.01 °C
ComplianceCE Certified
Sample ThroughputUp to 24 samples unattended (1-hour cycle)
Display10.4-inch color touchscreen
Solvent Consumption Reduction~50% vs. conventional capillary systems
Cleaning MethodAutomated air purge and solvent rinse
Capillary OptionsUbbelohde or ATLANTA-type viscometers
CalibrationSingle-point temperature calibration per capillary
Sample PreheatingIndividual sample heating up to 100 °C
Operating EnvironmentAmbient laboratory conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelRavenfield BS/C+ HTHS Viscometer
Instrument TypeBenchtop Fixed-Position Viscometer
Viscosity Range0–30 cP
Temperature Range40 °C to 180 °C
Temperature Resolution & Accuracy±0.02 °C
Shear Rate Range1×10⁵ s⁻¹ to 2×10⁶ s⁻¹
Test Cycle Time<5 min per sample
Repeatability≤2% RSD
ComplianceASTM D4741, ASTM D4683 (correlative), SAE J300, ACEA Specifications
Optional AccessoriesDR-Series Automated Sampler (up to 22 samples), LIMS Interface Module, Integrated Thermal Printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelUltraVIS192
Instrument TypeCapillary Viscometer (Fixed-Station)
Operating EnvironmentAmbient Temperature
Kinematic Viscosity Range5–50 mm²/s (cSt) @ 100 °C
Temperature Setpoints40 °C and 100 °C
Temperature Accuracy±0.01 °C
Temperature Resolution±0.01 °C
Sample Volume4–5 mL per test
ThroughputUp to 240 samples in 8 hours
ComplianceASTM D445
Control InterfaceTouchscreen + PC (up to 4 units per host)
LIMS IntegrationSupported
Sample CapacityDual 96-position removable sample trays (192 total)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelminiPV
Instrument TypeCapillary Viscometer (Fixed-Station)
Viscosity Range0.3–20,000 cSt
Temperature Range15–100 °C
Temperature Resolution0.001 °C
Temperature Accuracy±0.01 °C
Sample Volume~15 mL
Flow Time Resolution0.01 s
Cooling MethodPeltier-based (no external chiller required)
Sample Capacity10-position auto-sampler
Cleaning SystemDual-solvent + compressed air drying
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelminiAV-LT
Instrument TypeCapillary Viscometer (Fixed-Station)
Kinematic Viscosity Rangeup to 20,000 mm²/s
Temperature Range−40 °C to +30 °C
Temperature Stability±0.05 °C
ComplianceASTM D445, D1655, D2532, ISO 3104, ISO 3105, IP 71, DEF STAN 91-91, GB/T 265
Cooling MethodIntegrated Peltier Thermoelectric System with Air–Water Heat Exchange
Sample Volume~6 mL
Cleaning & DryingAutomated solvent rinse and thermal drying at +30 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelminiQV-X
Instrument TypeFixed-Position Capillary Viscometer
Operating EnvironmentAmbient Temperature
Viscosity Range0.5–10,000 mm²/s
ComplianceASTM D445
Sample Throughput<3 min per sample
Automation25-position Rotating Autosampler with Integrated Cleaning & Drying
ConfigurationSample-to-Sample Mode
CategoryPhysical Property Testing Instrument / Capillary Viscometer
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare