Add to compare
BrandEraly & Associés
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHELIOS S&N
Measurement ElementsSulfur (S), Nitrogen (N)
Measurement PrincipleUV Fluorescence (S) / Chemiluminescence (N)
Detection Limit5 ppb (S), 5 ppb–10% (N)
Quantitation Range10 ppb–10% (S & N)
Furnace Temperature RangeUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Carrier GasesO₂ (99.998%, 3 bar), Ar (99.995%, 3 bar)
Display7-inch touchscreen interface
LanguagesEnglish, French, Spanish, German, Russian, Chinese
ComplianceASTM D5453, D6667, D7183, D7551, D4629, D6069, D5762
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
ModelHELIOS S
Measurement ElementSulfur
Measurement PrincipleUltraviolet Fluorescence (UVF)
Detection Limit5 ppb
Quantitation Limit10 ppb
Measurement Range5 ppb – 10% w/w
Combustion Furnace TemperatureUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Gas RequirementsO₂ ≥99.998% at 3 bar, Ar ≥99.995% at 3 bar
Power Supply110/230 V, 50/60 Hz, 800 W
Dimensions (W×H×D)51 × 78 × 56 cm
Weight32 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
ModelHELIOS SN&CL
Measurement ElementsSulfur (S), Nitrogen (N), Chlorine (Cl)
Measurement PrinciplesUV Fluorescence (S), Chemiluminescence (N), Coulometric Titration (Cl)
Detection Limits5 ppb (S), 5 ppb–10% (N), 50 ppb–80+% (Cl)
Quantitation Ranges10 ppb–100 ppm (S), 10 ppb N–10% (N), <0.1 ppm–80+% (Cl)
Combustion Furnace TemperatureUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Carrier GasesO₂ (99.998%, 3 bar), Ar (99.995%, 3 bar)
Built-in LanguagesEnglish, French, Spanish, German, Russian, Chinese
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
ModelHELIOS N
Measurement ElementNitrogen
Measurement PrincipleChemiluminescence Detection
Detection Limit5 ppb
Quantitation Range10 ppb – 10 %
Furnace Temperature RangeUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Carrier GasesO₂ (99.998%, 3 bar), Ar (99.995%, 3 bar)
Power Supply110/230 V, 50/60 Hz, 800 W
Dimensions (W×H×D)51 × 78 × 56 cm
Weight32 kg