| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS S&N |
| Measurement Elements | Sulfur (S), Nitrogen (N) |
| Measurement Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Detection Limit | 5 ppb (S), 5 ppb–10% (N) |
| Quantitation Range | 10 ppb–10% (S & N) |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Display | 7-inch touchscreen interface |
| Languages | English, French, Spanish, German, Russian, Chinese |
| Compliance | ASTM D5453, D6667, D7183, D7551, D4629, D6069, D5762 |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS S |
| Measurement Element | Sulfur |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Detection Limit | 5 ppb |
| Quantitation Limit | 10 ppb |
| Measurement Range | 5 ppb – 10% w/w |
| Combustion Furnace Temperature | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Gas Requirements | O₂ ≥99.998% at 3 bar, Ar ≥99.995% at 3 bar |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 51 × 78 × 56 cm |
| Weight | 32 kg |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS SN&CL |
| Measurement Elements | Sulfur (S), Nitrogen (N), Chlorine (Cl) |
| Measurement Principles | UV Fluorescence (S), Chemiluminescence (N), Coulometric Titration (Cl) |
| Detection Limits | 5 ppb (S), 5 ppb–10% (N), 50 ppb–80+% (Cl) |
| Quantitation Ranges | 10 ppb–100 ppm (S), 10 ppb N–10% (N), <0.1 ppm–80+% (Cl) |
| Combustion Furnace Temperature | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Built-in Languages | English, French, Spanish, German, Russian, Chinese |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS N |
| Measurement Element | Nitrogen |
| Measurement Principle | Chemiluminescence Detection |
| Detection Limit | 5 ppb |
| Quantitation Range | 10 ppb – 10 % |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 51 × 78 × 56 cm |
| Weight | 32 kg |