Empowering Scientific Discovery

Shanghai Bang'an Testing Engineering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOLGE
OriginSouth Korea
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFerro-Mon Sensor
Product TypeOnline Instrument
Detection ParameterFerrous Wear Debris Concentration
Output FormatFe Saturation (%)
Communication InterfaceLoRa Wireless
CompliancePQ Standard
Application DomainIn-Service Lubricating Oil Monitoring for Rotating Machinery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelAFP-102
Standards ComplianceASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248
Cooling MethodIntegrated Peltier thermoelectric module (no formaldehyde or external chiller required)
Temperature RangeAmbient to –60 °C
Temperature Resolution0.1 °C
Cooling ModesLinear ramp and stepwise (isothermal) cooling
Detection PrincipleDual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket
Sample CompatibilityDiesel fuels, heating oils, biodiesel blends, and other middle distillates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
ModelAquamax KF PRO LPG
ApplicationCoulometric Karl Fischer titration for trace moisture determination in pressurized liquefied gases (LPG, LNG) and vapor-phase hydrocarbon streams
Detection Range0.1–1000 µg H₂O (equivalent to 0.1–500 ppmv in gas phase, depending on sample volume and density)
Sample FormLiquid or vapor-phase, pressurized
Automation LevelFully automated sample introduction, titration, rinsing, and method execution
ComplianceDesigned per ISO 8573-3, ASTM D6304, ASTM D7429, and EN 15472
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
TypeElectromagnetic Oscillating Tribometer
Load Range1–3000 N
Frequency Range1–500 Hz
Oscillation Amplitude0.005–4 mm
Temperature RangeAmbient to +400 °C (optional up to +1000 °C)
Force SensingHigh-accuracy piezoelectric tribosensors
Displacement MonitoringLVDT-based real-time closed-loop control
Compliance StandardsASTM D5706, D5707, D6425, D7421, D7594, E2789
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
ModelFBT-12000
Load CapacityUp to 12,000 N (closed-loop servo-controlled)
Torque Measurement Range0–20 N·m
Rotational Speed0–3000 rpm (0.1 rpm resolution)
Temperature RangeAmbient to +150 °C
Optional Low-Temperature ControlAmbient to –40 °C
ComplianceASTM D2596, D2783, D2266, D4172, D5183
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
ModelTAN/TBN Titrator
Application Standard ComplianceIEC 62021-1, ISO 3771, ASTM D664, ASTM D2896, ASTM D4739
Titration MethodPotentiometric Volumetric Titration in Anhydrous Medium
Measurement Range0.01–250 mg KOH/g
Resolution0.01 mg KOH/g
Power Supply100–240 V AC, 50/60 Hz, 30 VA
Stirrer Output12 V DC, 500 mA
Dimensions (W × H × D)30 × 45 × 30 cm (including reagent changer height)
Weight~3.5 kg (with reagent changer and empty bottles)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
ModelMFT-3000
Load Range0–3000 N
Reciprocating Stroke0–30 mm
Frequency Range0–80 Hz
Temperature ControlAmbient to +500 °C (up to +1000 °C optional)
Low-Temperature OptionAmbient to –60 °C
Thermal Cycling Option–40 °C to +180 °C
Rotational Mode (optional)0.1–5000 rpm, 0.1 rpm resolution
ComplianceASTM G133, G181, G119, G174, D5706, D5707, SH/T 0784, SH/T 0721, DIN 51834
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
ModelFFT-M1
ApplicationTribological Evaluation of Fuels and Lubricants
ComplianceASTM D6079, ISO 12156-1, SH/T 0765, EN 590, JPI-5S-50-9, IP 450
Load Range0–1.0 kg
Frequency Range1–300 Hz
Stroke Amplitude0.005–2 mm
Operating TemperatureAmbient to +200 °C
Test ModeBoundary Lubrication Assessment under Oscillatory Sliding Conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOLGE
OriginSouth Korea
ModelVARTECTOR
ApplicationASTM D7843-compliant film potential analysis of phosphate ester fire-resistant hydraulic fluids (EHC systems)
Measurement PrincipleReflectance-based colorimetric quantification of deposited insolubles on membrane filters using CIE L*a*b* color space
ComplianceFully aligned with ASTM D7843–21 “Standard Test Method for Quantifying Potential for Insoluble Formation in Phosphate Ester Fluids”
Automation LevelFully automated load control, optical measurement, system verification, and diagnostic reporting
Data OutputΔE, ΔL*, a*, b* values
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
Modelaqua 40.00
Measurement Range1 µg – 100 mg
Resolution0.1 µg
Repeatability±3 µg (for 10–1000 µg water)
Temperature Control Range35 °C – 300 °C
Power Supply230 V
Sample IntroductionOptional automated sample changer
Gas SystemClosed-loop, carrier-gas-free dynamic headspace
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
ModelBOR-3000
Load CapacityUp to 3000 N
Rotational Speed Range0.1–5000 rpm (0.1 rpm resolution)
Temperature RangeAmbient to +200 °C
Optional Low-Temp Control−40 °C to +200 °C
Optional High-Temp ControlAmbient to +500 °C
Test Standards ComplianceASTM G77, ASTM D2509, ASTM D2714, ASTM D2782, ASTM D2981, ASTM D3704, SH/T 0203, GB/T 11144
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCINRG
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCS-APC-2
Product CategoryLaboratory Instrument
Test ParameterContaminant Particles
ComplianceASTM D7647-10
Sample Processing Time4–5 min/sample
Solvent Consumption40 mL/sample
Autosampler Capacity102 samples (104-position tray
Sensor ModelKLOTZ LDS 45/50 Laser Sensor
Measurement Range1.5 µm – 100 µm
Flow Rate30 mL/min (calibrated)
Detection Thresholds25,000 particles/mL at ≥4 µm (neat oil), 50,000 particles/mL at ≥4 µm (1:1 dilution)
Volume Accuracy±2% (pre-dilution)
Customizable ReportingUser-defined pass/fail limits at 4 µm, 6 µm, and 14 µm
Data Export FieldsSolvent blank count, sample volume, dilution ratio, raw particle counts per channel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAquamax KF PRO OIL
Product TypeLaboratory Instrument
Measurement ParameterTrace Water Content (ppm to %)
ComplianceASTM D6304, GB/T 11133
Measurement Range0.0001–99% w/w
Heating Temperature Range35–250 °C (isothermal or programmable ramp)
Sample IntroductionDirect injection into heated furnace
Carrier GasNot required (closed-loop system)
Reagent ConsumptionSingle reagent cartridge supports >1000 determinations
Water SpeciationDifferentiates free water and chemically bound water via thermal profiling
Blank-Free OperationEliminates need for blank correction
Form FactorBenchtop / Portable field unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAtten2
OriginSpain
ModelOilWear S120
Product TypeOnline Instrument
Detection TargetSolid Contaminants & Degradation Indicators
Particle Size Range≥4 µm
Source Discrimination Capability≥20 µm (size + shape-based classification)
Compliance StandardsISO 4406, SAE AS4059, NAS 1638
Communication InterfacesAnalog (4–20 mA), Digital (RS-485, Modbus RTU), PLC/SCADA/PC Compatible
Self-Calibration & DiagnosticsYes
Configurable Alarm ThresholdsYes
Integrated Oil Health MonitoringCompatible with Atten2 OilHealth Platform
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAtten2
OriginSpain
ModelOiHealth PROBE
Product TypeOnline Instrument
Voltage24 V DC
Current Consumption<200 mA
Digital OutputsRS485 (Modbus RTU), Ethernet RJ45 (Modbus TCP/IP, FTP, Telnet)
Maximum Operating Pressure5 bar
Viscosity Range0–460 cSt
Operating Temperature−20 °C to +80 °C
Ingress ProtectionIP65
Hydraulic Connection1/2″ BSP
CertificationsCE, GL Class pending
Detection PrincipleOptical Absorption & Scattering Spectroscopy
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAtten2
OriginSpain
ModelOilMoisture
Product TypeOnline Instrument
Detection ParameterWater Content
Compliance StandardASTM D6304
Sensitivityppm-level
Power Supply24 V DC, <100 mA
Output InterfaceModbus RTU (RS-485)
Max Operating Pressure12 bar
Operating Temperature Range0–80 °C
Viscosity Compatibilityup to 680 cSt
Housing MaterialAluminum (stainless steel optional)
Optical WindowBK7 glass
Sealing MaterialFluoroelastomer (FKM)
Ingress ProtectionIP65
CertificationCE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAtten2
OriginSpain
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAtten2 SMK Smart Oil Filtration Kit
Product TypeOnline Monitoring Instrument
Measured ParametersParticle Contamination, Air Bubble Content, Foam Inhibitor Condition, Optional Water Content
Compliance StandardsISO 4406:2017, SAE AS4059F, NAS 1638 Class
Power Supply24 V DC, <250 mA
Particle & Bubble Count OutputISO Code, p/mL, b/mL
Volumetric Flow VisualizationL/min
Optional Humidity Sensor (Water-in-Oil)ppm
Digital InterfaceLocal Display + Ethernet RJ45 (IP, FTP, Telnet)
Max Operating Pressure20 bar
Operating Temperature Range0–80 °C
Kinematic Viscosity Range0–540 cSt
Counting Accuracy±1 ISO Code
Enclosure RatingIP65
Added to wishlistRemoved from wishlist 0
Add to compare
Brandatten2
OriginSpain
ModelOilCMS
Instrument TypeOnline Lubricant Condition Monitor
Detection ParametersParticle Contamination, Water Content (RH%), Oil Degradation State, Viscosity Estimation (up to 3000 cSt)
Compliance StandardsISO 4406, SAE AS4059, NAS 1638
Display10-inch capacitive touchscreen
PowerIntegrated rechargeable lithium battery
Data StorageLocal database for up to 500 oil samples with trend aggregation
Flow ControlBuilt-in motorized pump with optional high-pressure adapter (compatible with real-time recirculation systems up to 350 bar)
Particle Analysis MethodDigital imaging with bubble suppression and morphological classification