Empowering Scientific Discovery

Shanghai Bang'an Testing Engineering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelMPC-6
Test MethodASTM D6749 (Air-Pressure Method), ASTM D97, ISO 3016
Sample Volume4.5 mL
Temperature Interval1 °C or 2 °C
RepeatabilityPour Point ±1 °C (1 °C interval) / ±3 °C (3 °C interval)
Cooling SourceIntegrated Peltier Module
ComplianceASTM, ISO, GLP-ready architecture
Data OutputAuto-generated report with timestamped test logs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERAFLASH
Detection MethodClosed-Cup
Operation ModeFully Automatic
Applicable StandardsASTM D6450, ASTM D7094, SH/T 0768
RepeatabilityExcellent
Ignition MethodElectric Arc Ignition
Temperature Range−25 °C to 420 °C (standard configuration: 0 °C to 200 °C
Sample Volume1 mL (ASTM D6450), 2 mL (ASTM D7094)
Cooling/Heating TechnologyPatented PBT (Peltier-Based Thermoregulation)
Data Storage Capacity>100,000 test reports with full audit trail
Power Supply85–264 V AC or 12 V DC
Sample ThroughputUp to 12 samples/hour
Temperature Accuracy±0.1 °C
Integrated Pollution MonitoringCPT (Contamination Prevention Technology)
Optional ModulesEF01-HTM (high-temp module, up to 420 °C), EF02 LT (low-temp module, −40 °C to 120 °C with external chiller)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTamson Instruments
OriginNetherlands
ModelTFBT
Standards ComplianceASTM D2068, IP 387, SH/T 0895
Test MethodsIntegrated Method A & Method B
Display7-inch capacitive touchscreen with real-time pressure/flow/temperature curves
User InterfaceStep-by-step graphical guidance
CalibrationFully electronic (no mechanical adjustment required)
OutputIntegrated thermal printer
Temperature ControlPID-regulated heating block (ambient to 100 °C, ±0.5 °C stability)
Flow MeasurementHigh-precision mass flow sensor (range: 0–200 mL/min, resolution: 0.1 mL/min)
Pressure SensingDigital differential pressure transducer (0–1000 kPa, accuracy: ±0.5% FS)
Power Supply100–240 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCANNON
OriginUSA
ModelminiAV-HT
Temperature Control Range40 °C to 150 °C
Kinematic Viscosity Measurement Range0.5 mm²/s (cSt) to 10,000 mm²/s (cSt)
Compliance StandardsAASHTO T201, ASTM D2170, ASTM D445
ThroughputUp to 12 samples/hour
SoftwareVISCPRO® PC (supports up to 4 instruments per workstation)
Sample PreheaterAdjustable
Waste Line HeaterIntegrated
Solvent InletsDual standard ports
CalibrationSingle-point temperature calibration capability
Capillary ExchangeTool-free, operator-performed in minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelST1011
Temperature RangeAmbient to 130 °C
Temperature Stability±0.2 °C
Number of Test Positions6
Heating Power2 kW
Power SupplyAC 220 V, 50 Hz
Dimensions (W×D×H)260 × 450 × 455 mm
Weight20 kg
ConstructionFull stainless-steel housing
ComplianceASTM D130, IP 154, ISO 2160, GB/T 5096
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERASPEC OIL
ComplianceASTM E2412, D2688, D7412–D7418, D7624
Measurement PrincipleMid-IR Absorption Spectroscopy with Fixed-Path Transmission Cell
Sample Volume10 mL
Flow Path Cell Thickness100 µm
Viscosity Range0–2000 cSt (at 20 °C)
Analysis Time60–120 s (viscosity-dependent)
Warm-up Time≤30 s
Auto-samplingIntegrated precision peristaltic pump
Auto-cleaningSolvent or next-sample flush
Display7-inch capacitive touchscreen
ConnectivityEthernet (RJ45), USB 2.0, RS-232
Data Storage≥3000 full spectral reports with metadata
Remote AccessYes, via Ethernet-enabled diagnostic and service interface
Alarm LoggingTimestamped event tracking with result correlation
Software ComplianceAudit-trail capable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelAD-7
Temperature Range0–450 °C
Condenser & Receiving Chamber CoolingPeltier-based with internal recirculating coolant
Temperature Resolution0.1 °C
Condenser Temp Control Range0–69.9 °C (±0.2 °C accuracy)
Receiving Chamber Temp Control Range0–50 °C (±0.05 °C accuracy)
Distillate Rate Control2–10 mL/min (PID-regulated, factory default 4.5 mL/min)
Initial Boiling Point (IBP) DetectionInfrared photoelectric sensor
Dry Point DetectionManual visual or optional automatic sensor
Heating System24 V/600 W vortex-type heater with forced-air cooling
Safety SystemsFlame detection sensor, automatic power cutoff, integrated fire suppressant discharge, flask support misalignment lockout, sensor fault monitoring
Data Storage5,000 test records
Test Method Presets200 programmable modes
InterfacesRS-232C, Ethernet (for TDAS/LIMS), USB
Display10.4″ capacitive touchscreen LCD
Atmospheric Pressure CompensationAutomatic or manual input
ComplianceASTM D86, ASTM D850, ASTM D1078, GB/T 6536
SoftwareTDAS (Test Data Acquisition System) with curve export, remote operation, and printer output (thermal paper)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOLGE
OriginSouth Korea
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFerro-Mon Sensor
Product TypeOnline Instrument
Detection ParameterFerrous Wear Debris Concentration
Output FormatFe Saturation (%)
Communication InterfaceLoRa Wireless
CompliancePQ Standard
Application DomainIn-Service Lubricating Oil Monitoring for Rotating Machinery
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelAFP-102
Standards ComplianceASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248
Cooling MethodIntegrated Peltier thermoelectric module (no formaldehyde or external chiller required)
Temperature RangeAmbient to –60 °C
Temperature Resolution0.1 °C
Cooling ModesLinear ramp and stepwise (isothermal) cooling
Detection PrincipleDual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket
Sample CompatibilityDiesel fuels, heating oils, biodiesel blends, and other middle distillates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
ModelAquamax KF PRO LPG
ApplicationCoulometric Karl Fischer titration for trace moisture determination in pressurized liquefied gases (LPG, LNG) and vapor-phase hydrocarbon streams
Detection Range0.1–1000 µg H₂O (equivalent to 0.1–500 ppmv in gas phase, depending on sample volume and density)
Sample FormLiquid or vapor-phase, pressurized
Automation LevelFully automated sample introduction, titration, rinsing, and method execution
ComplianceDesigned per ISO 8573-3, ASTM D6304, ASTM D7429, and EN 15472
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSBS
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUHPV-100
PriceUpon Request
Viscosity Range0.7–20,000 cP (mPa·s)
Pressure RangeUp to 60,000 psi
Temperature Range−40 to +150 °C
Accuracy & Repeatability< ±2%
Sample Volume~10 cm³
Needle MaterialAluminum, Titanium, or Stainless Steel
Needle Density7 g/cm³
Instrument Weight68.0 kg (150 lbs)
Dimensions (H×W×D)61 × 107 × 61 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
TypeElectromagnetic Oscillating Tribometer
Load Range1–3000 N
Frequency Range1–500 Hz
Oscillation Amplitude0.005–4 mm
Temperature RangeAmbient to +400 °C (optional up to +1000 °C)
Force SensingHigh-accuracy piezoelectric tribosensors
Displacement MonitoringLVDT-based real-time closed-loop control
Compliance StandardsASTM D5706, D5707, D6425, D7421, D7594, E2789
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
ModelFBT-12000
Load CapacityUp to 12,000 N (closed-loop servo-controlled)
Torque Measurement Range0–20 N·m
Rotational Speed0–3000 rpm (0.1 rpm resolution)
Temperature RangeAmbient to +150 °C
Optional Low-Temperature ControlAmbient to –40 °C
ComplianceASTM D2596, D2783, D2266, D4172, D5183
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSBS
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPDVdi-120
PriceUpon Request
Viscosity Range2–10⁶ cP (mPa·s)
Temperature RangeAmbient (15–30 °C typical field use)
Accuracy & Repeatability±2% of reading
Sample Volume~25 mL
Needle MaterialAluminum, Titanium, or Stainless Steel
Needle Density2.916 g/cm³
Total Weight0.38 kg (0.83 lbs)
ComplianceASTM D5478, SAE AIR5704
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
ModelTAN/TBN Titrator
Application Standard ComplianceIEC 62021-1, ISO 3771, ASTM D664, ASTM D2896, ASTM D4739
Titration MethodPotentiometric Volumetric Titration in Anhydrous Medium
Measurement Range0.01–250 mg KOH/g
Resolution0.01 mg KOH/g
Power Supply100–240 V AC, 50/60 Hz, 30 VA
Stirrer Output12 V DC, 500 mA
Dimensions (W × H × D)30 × 45 × 30 cm (including reagent changer height)
Weight~3.5 kg (with reagent changer and empty bottles)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
ModelMFT-3000
Load Range0–3000 N
Reciprocating Stroke0–30 mm
Frequency Range0–80 Hz
Temperature ControlAmbient to +500 °C (up to +1000 °C optional)
Low-Temperature OptionAmbient to –60 °C
Thermal Cycling Option–40 °C to +180 °C
Rotational Mode (optional)0.1–5000 rpm, 0.1 rpm resolution
ComplianceASTM G133, G181, G119, G174, D5706, D5707, SH/T 0784, SH/T 0721, DIN 51834
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRtec
OriginUSA
ModelFFT-M1
ApplicationTribological Evaluation of Fuels and Lubricants
ComplianceASTM D6079, ISO 12156-1, SH/T 0765, EN 590, JPI-5S-50-9, IP 450
Load Range0–1.0 kg
Frequency Range1–300 Hz
Stroke Amplitude0.005–2 mm
Operating TemperatureAmbient to +200 °C
Test ModeBoundary Lubrication Assessment under Oscillatory Sliding Conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCheckfluid
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLTJ
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelSulfur Titrator
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSOLGE
OriginSouth Korea
ModelVARTECTOR
ApplicationASTM D7843-compliant film potential analysis of phosphate ester fire-resistant hydraulic fluids (EHC systems)
Measurement PrincipleReflectance-based colorimetric quantification of deposited insolubles on membrane filters using CIE L*a*b* color space
ComplianceFully aligned with ASTM D7843–21 “Standard Test Method for Quantifying Potential for Insoluble Formation in Phosphate Ester Fluids”
Automation LevelFully automated load control, optical measurement, system verification, and diagnostic reporting
Data OutputΔE, ΔL*, a*, b* values
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVISAYA
OriginUSA
ModelFOAM DDI
ComplianceASTM D892, ASTM D6082, GB/T 12579, SH/T 0722
Imaging SystemHigh-Resolution CCD with LED Illumination Control
Sample Volume~200 mL in 1000 mL calibrated cylinder
Temperature Control RangeAmbient to 99.9 °C
DisplayIntegrated HD Touchscreen Interface
Data OutputExportable CSV/Excel reports with timestamped video log
Software FeaturesReal-time foam height tracking, algorithmic foam volume quantification, manual result override, full-test video recording
Added to wishlistRemoved from wishlist 0
Add to compare
BrandECH
OriginGermany
Modelaqua 40.00
Measurement Range1 µg – 100 mg
Resolution0.1 µg
Repeatability±3 µg (for 10–1000 µg water)
Temperature Control Range35 °C – 300 °C
Power Supply230 V
Sample IntroductionOptional automated sample changer
Gas SystemClosed-loop, carrier-gas-free dynamic headspace
ComplianceDesigned for GLP/GMP environments with audit-trail-capable software support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCheckfluid
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLP Series
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTANAKA
OriginJapan
ModelABL-8
Test MethodClosed-Cup (Abel)
Operation ModeFully Automatic
Applicable StandardsGB/T 21789, IP 170, ISO 13736, ISO 1516, ISO 1523
Temperature Range−30 °C to +80 °C
Ignition SystemDual-mode (Gas Flame & Electric Spark)
RepeatabilityHigh
Cooling MethodPeltier-based Semiconductor Cooling
Display5.7-inch Color LCD
Data Storage Capacity200 Test Records
Atmospheric Pressure CompensationIntegrated Barometric Sensor
Safety FeaturesAuto Fire Suppression, Fault Diagnostics, Wind Shield Enclosure
Compliance SupportASTM D3278, ISO/IEC 17025 Traceability Framework, GLP Audit Trail Ready