Empowering Scientific Discovery

Shanghai Bang'an Testing Engineering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERAOIL
TypeRotating Disk Electrode Optical Emission Spectrometer (RDE-OES)
Detection PrincipleArc Spark Optical Emission Spectrometry
Measurement Time≤30 s per sample
Elements QuantifiedUp to 32 metallic elements
Detection Limit (LOD)Sub-ppm for most elements (standard configuration)
Sample TypesLubricants, fuels, coolants, process water, hydraulic fluids
ComplianceASTM D6728, ASTM D6595, NB/SH/T 0865
Integrated SystemBuilt-in 10-inch color touchscreen, embedded industrial PC, automated electrode dresser, and active ventilation unit
Dimensions & PortabilityCompact benchtop footprint
Sample PreparationNone required — direct liquid analysis
Gas RequirementNone (no carrier gas, no plasma gas)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHELIOS S&N
Measurement ElementsSulfur (S), Nitrogen (N)
Measurement PrincipleUV Fluorescence (S) / Chemiluminescence (N)
Detection Limit5 ppb (S), 5 ppb–10% (N)
Quantitation Range10 ppb–10% (S & N)
Furnace Temperature RangeUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Carrier GasesO₂ (99.998%, 3 bar), Ar (99.995%, 3 bar)
Display7-inch touchscreen interface
LanguagesEnglish, French, Spanish, German, Russian, Chinese
ComplianceASTM D5453, D6667, D7183, D7551, D4629, D6069, D5762
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
ModelHELIOS S
Measurement ElementSulfur
Measurement PrincipleUltraviolet Fluorescence (UVF)
Detection Limit5 ppb
Quantitation Limit10 ppb
Measurement Range5 ppb – 10% w/w
Combustion Furnace TemperatureUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Gas RequirementsO₂ ≥99.998% at 3 bar, Ar ≥99.995% at 3 bar
Power Supply110/230 V, 50/60 Hz, 800 W
Dimensions (W×H×D)51 × 78 × 56 cm
Weight32 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
ModelHELIOS SN&CL
Measurement ElementsSulfur (S), Nitrogen (N), Chlorine (Cl)
Measurement PrinciplesUV Fluorescence (S), Chemiluminescence (N), Coulometric Titration (Cl)
Detection Limits5 ppb (S), 5 ppb–10% (N), 50 ppb–80+% (Cl)
Quantitation Ranges10 ppb–100 ppm (S), 10 ppb N–10% (N), <0.1 ppm–80+% (Cl)
Combustion Furnace TemperatureUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Carrier GasesO₂ (99.998%, 3 bar), Ar (99.995%, 3 bar)
Built-in LanguagesEnglish, French, Spanish, German, Russian, Chinese
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHELIOS CL
PriceUpon Request
Measurement PrincipleCoulometric Titration (Absolute Method)
Sample TypesLiquids (including viscous), Gases (incl. LPG), Solids, Slurries, Polymers, Fuels, Environmental Matrices
ComplianceASTM D4929, ASTM D5808, ASTM D5194, ASTM D6721, GB/T 18612, SH/T 1757, GB/T 23971-B, SH/T 0677-A, UOP 779, ISO 9562, NF EN 12260, NF EN 14077
Detection Range0.1 ppm to 80 wt% Cl (matrix-dependent, no dilution required)
Electrolyte OptionsThree grades for low-, medium-, and high-concentration applications
Dual-Cell ArchitectureTwo independent coulometric titration cells
FurnaceF2-type high-temperature combustion furnace, max. 1100 °C
Carrier GasesO₂ (99.998%, 3 bar) and Ar (99.995%, 3 bar)
Sample Introduction20–80 µL liquid
Power Supply110/230 V, 50/60 Hz, 800 W
Dimensions (W×H×D)66 × 83 × 56 cm
Weight32 kg
Warranty5-year hardware warranty
Language InterfaceEnglish, French, Spanish, German, Russian, Chinese
Safety FeaturesAutomated acid-free dry/wash system, light-shielded semi-pressurized titration cell, integrated gas flow control and pressure monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEraly & Associés
OriginFrance
ModelHELIOS N
Measurement ElementNitrogen
Measurement PrincipleChemiluminescence Detection
Detection Limit5 ppb
Quantitation Range10 ppb – 10 %
Furnace Temperature RangeUp to 1100 °C
Temperature Control Accuracy±1 °C
Sample Volume20–80 µL (liquid), 10 mL (gas), 20 µL (LPG)
Carrier GasesO₂ (99.998%, 3 bar), Ar (99.995%, 3 bar)
Power Supply110/230 V, 50/60 Hz, 800 W
Dimensions (W×H×D)51 × 78 × 56 cm
Weight32 kg