- All
- Favorite
- Popular
- Most rated
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | MPC-6 |
| Test Method | ASTM D6749 (Air-Pressure Method), ASTM D97, ISO 3016 |
| Sample Volume | 4.5 mL |
| Temperature Interval | 1 °C or 2 °C |
| Repeatability | Pour Point ±1 °C (1 °C interval) / ±3 °C (3 °C interval) |
| Cooling Source | Integrated Peltier Module |
| Compliance | ASTM, ISO, GLP-ready architecture |
| Data Output | Auto-generated report with timestamped test logs |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAFLASH |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D6450, ASTM D7094, SH/T 0768 |
| Repeatability | Excellent |
| Ignition Method | Electric Arc Ignition |
| Temperature Range | −25 °C to 420 °C (standard configuration: 0 °C to 200 °C |
| Sample Volume | 1 mL (ASTM D6450), 2 mL (ASTM D7094) |
| Cooling/Heating Technology | Patented PBT (Peltier-Based Thermoregulation) |
| Data Storage Capacity | >100,000 test reports with full audit trail |
| Power Supply | 85–264 V AC or 12 V DC |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Accuracy | ±0.1 °C |
| Integrated Pollution Monitoring | CPT (Contamination Prevention Technology) |
| Optional Modules | EF01-HTM (high-temp module, up to 420 °C), EF02 LT (low-temp module, −40 °C to 120 °C with external chiller) |
| Brand | Tamson Instruments |
|---|---|
| Origin | Netherlands |
| Model | TFBT |
| Standards Compliance | ASTM D2068, IP 387, SH/T 0895 |
| Test Methods | Integrated Method A & Method B |
| Display | 7-inch capacitive touchscreen with real-time pressure/flow/temperature curves |
| User Interface | Step-by-step graphical guidance |
| Calibration | Fully electronic (no mechanical adjustment required) |
| Output | Integrated thermal printer |
| Temperature Control | PID-regulated heating block (ambient to 100 °C, ±0.5 °C stability) |
| Flow Measurement | High-precision mass flow sensor (range: 0–200 mL/min, resolution: 0.1 mL/min) |
| Pressure Sensing | Digital differential pressure transducer (0–1000 kPa, accuracy: ±0.5% FS) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV-HT |
| Temperature Control Range | 40 °C to 150 °C |
| Kinematic Viscosity Measurement Range | 0.5 mm²/s (cSt) to 10,000 mm²/s (cSt) |
| Compliance Standards | AASHTO T201, ASTM D2170, ASTM D445 |
| Throughput | Up to 12 samples/hour |
| Software | VISCPRO® PC (supports up to 4 instruments per workstation) |
| Sample Preheater | Adjustable |
| Waste Line Heater | Integrated |
| Solvent Inlets | Dual standard ports |
| Calibration | Single-point temperature calibration capability |
| Capillary Exchange | Tool-free, operator-performed in minutes |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ST1011 |
| Temperature Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Number of Test Positions | 6 |
| Heating Power | 2 kW |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 450 × 455 mm |
| Weight | 20 kg |
| Construction | Full stainless-steel housing |
| Compliance | ASTM D130, IP 154, ISO 2160, GB/T 5096 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC OIL |
| Compliance | ASTM E2412, D2688, D7412–D7418, D7624 |
| Measurement Principle | Mid-IR Absorption Spectroscopy with Fixed-Path Transmission Cell |
| Sample Volume | 10 mL |
| Flow Path Cell Thickness | 100 µm |
| Viscosity Range | 0–2000 cSt (at 20 °C) |
| Analysis Time | 60–120 s (viscosity-dependent) |
| Warm-up Time | ≤30 s |
| Auto-sampling | Integrated precision peristaltic pump |
| Auto-cleaning | Solvent or next-sample flush |
| Display | 7-inch capacitive touchscreen |
| Connectivity | Ethernet (RJ45), USB 2.0, RS-232 |
| Data Storage | ≥3000 full spectral reports with metadata |
| Remote Access | Yes, via Ethernet-enabled diagnostic and service interface |
| Alarm Logging | Timestamped event tracking with result correlation |
| Software Compliance | Audit-trail capable |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AD-7 |
| Temperature Range | 0–450 °C |
| Condenser & Receiving Chamber Cooling | Peltier-based with internal recirculating coolant |
| Temperature Resolution | 0.1 °C |
| Condenser Temp Control Range | 0–69.9 °C (±0.2 °C accuracy) |
| Receiving Chamber Temp Control Range | 0–50 °C (±0.05 °C accuracy) |
| Distillate Rate Control | 2–10 mL/min (PID-regulated, factory default 4.5 mL/min) |
| Initial Boiling Point (IBP) Detection | Infrared photoelectric sensor |
| Dry Point Detection | Manual visual or optional automatic sensor |
| Heating System | 24 V/600 W vortex-type heater with forced-air cooling |
| Safety Systems | Flame detection sensor, automatic power cutoff, integrated fire suppressant discharge, flask support misalignment lockout, sensor fault monitoring |
| Data Storage | 5,000 test records |
| Test Method Presets | 200 programmable modes |
| Interfaces | RS-232C, Ethernet (for TDAS/LIMS), USB |
| Display | 10.4″ capacitive touchscreen LCD |
| Atmospheric Pressure Compensation | Automatic or manual input |
| Compliance | ASTM D86, ASTM D850, ASTM D1078, GB/T 6536 |
| Software | TDAS (Test Data Acquisition System) with curve export, remote operation, and printer output (thermal paper) |
| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ferro-Mon Sensor |
| Product Type | Online Instrument |
| Detection Parameter | Ferrous Wear Debris Concentration |
| Output Format | Fe Saturation (%) |
| Communication Interface | LoRa Wireless |
| Compliance | PQ Standard |
| Application Domain | In-Service Lubricating Oil Monitoring for Rotating Machinery |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AFP-102 |
| Standards Compliance | ASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248 |
| Cooling Method | Integrated Peltier thermoelectric module (no formaldehyde or external chiller required) |
| Temperature Range | Ambient to –60 °C |
| Temperature Resolution | 0.1 °C |
| Cooling Modes | Linear ramp and stepwise (isothermal) cooling |
| Detection Principle | Dual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket |
| Sample Compatibility | Diesel fuels, heating oils, biodiesel blends, and other middle distillates |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | Aquamax KF PRO LPG |
| Application | Coulometric Karl Fischer titration for trace moisture determination in pressurized liquefied gases (LPG, LNG) and vapor-phase hydrocarbon streams |
| Detection Range | 0.1–1000 µg H₂O (equivalent to 0.1–500 ppmv in gas phase, depending on sample volume and density) |
| Sample Form | Liquid or vapor-phase, pressurized |
| Automation Level | Fully automated sample introduction, titration, rinsing, and method execution |
| Compliance | Designed per ISO 8573-3, ASTM D6304, ASTM D7429, and EN 15472 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UHPV-100 |
| Price | Upon Request |
| Viscosity Range | 0.7–20,000 cP (mPa·s) |
| Pressure Range | Up to 60,000 psi |
| Temperature Range | −40 to +150 °C |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ~10 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 7 g/cm³ |
| Instrument Weight | 68.0 kg (150 lbs) |
| Dimensions (H×W×D) | 61 × 107 × 61 cm |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Type | Electromagnetic Oscillating Tribometer |
| Load Range | 1–3000 N |
| Frequency Range | 1–500 Hz |
| Oscillation Amplitude | 0.005–4 mm |
| Temperature Range | Ambient to +400 °C (optional up to +1000 °C) |
| Force Sensing | High-accuracy piezoelectric tribosensors |
| Displacement Monitoring | LVDT-based real-time closed-loop control |
| Compliance Standards | ASTM D5706, D5707, D6425, D7421, D7594, E2789 |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | FBT-12000 |
| Load Capacity | Up to 12,000 N (closed-loop servo-controlled) |
| Torque Measurement Range | 0–20 N·m |
| Rotational Speed | 0–3000 rpm (0.1 rpm resolution) |
| Temperature Range | Ambient to +150 °C |
| Optional Low-Temperature Control | Ambient to –40 °C |
| Compliance | ASTM D2596, D2783, D2266, D4172, D5183 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PDVdi-120 |
| Price | Upon Request |
| Viscosity Range | 2–10⁶ cP (mPa·s) |
| Temperature Range | Ambient (15–30 °C typical field use) |
| Accuracy & Repeatability | ±2% of reading |
| Sample Volume | ~25 mL |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 2.916 g/cm³ |
| Total Weight | 0.38 kg (0.83 lbs) |
| Compliance | ASTM D5478, SAE AIR5704 |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | TAN/TBN Titrator |
| Application Standard Compliance | IEC 62021-1, ISO 3771, ASTM D664, ASTM D2896, ASTM D4739 |
| Titration Method | Potentiometric Volumetric Titration in Anhydrous Medium |
| Measurement Range | 0.01–250 mg KOH/g |
| Resolution | 0.01 mg KOH/g |
| Power Supply | 100–240 V AC, 50/60 Hz, 30 VA |
| Stirrer Output | 12 V DC, 500 mA |
| Dimensions (W × H × D) | 30 × 45 × 30 cm (including reagent changer height) |
| Weight | ~3.5 kg (with reagent changer and empty bottles) |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | MFT-3000 |
| Load Range | 0–3000 N |
| Reciprocating Stroke | 0–30 mm |
| Frequency Range | 0–80 Hz |
| Temperature Control | Ambient to +500 °C (up to +1000 °C optional) |
| Low-Temperature Option | Ambient to –60 °C |
| Thermal Cycling Option | –40 °C to +180 °C |
| Rotational Mode (optional) | 0.1–5000 rpm, 0.1 rpm resolution |
| Compliance | ASTM G133, G181, G119, G174, D5706, D5707, SH/T 0784, SH/T 0721, DIN 51834 |
| Brand | Rtec |
|---|---|
| Origin | USA |
| Model | FFT-M1 |
| Application | Tribological Evaluation of Fuels and Lubricants |
| Compliance | ASTM D6079, ISO 12156-1, SH/T 0765, EN 590, JPI-5S-50-9, IP 450 |
| Load Range | 0–1.0 kg |
| Frequency Range | 1–300 Hz |
| Stroke Amplitude | 0.005–2 mm |
| Operating Temperature | Ambient to +200 °C |
| Test Mode | Boundary Lubrication Assessment under Oscillatory Sliding Conditions |
| Brand | Checkfluid |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTJ |
| Pricing | Upon Request |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Sulfur Titrator |
| Pricing | Upon Request |
| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Model | VARTECTOR |
| Application | ASTM D7843-compliant film potential analysis of phosphate ester fire-resistant hydraulic fluids (EHC systems) |
| Measurement Principle | Reflectance-based colorimetric quantification of deposited insolubles on membrane filters using CIE L*a*b* color space |
| Compliance | Fully aligned with ASTM D7843–21 “Standard Test Method for Quantifying Potential for Insoluble Formation in Phosphate Ester Fluids” |
| Automation Level | Fully automated load control, optical measurement, system verification, and diagnostic reporting |
| Data Output | ΔE, ΔL*, a*, b* values |
| Brand | VISAYA |
|---|---|
| Origin | USA |
| Model | FOAM DDI |
| Compliance | ASTM D892, ASTM D6082, GB/T 12579, SH/T 0722 |
| Imaging System | High-Resolution CCD with LED Illumination Control |
| Sample Volume | ~200 mL in 1000 mL calibrated cylinder |
| Temperature Control Range | Ambient to 99.9 °C |
| Display | Integrated HD Touchscreen Interface |
| Data Output | Exportable CSV/Excel reports with timestamped video log |
| Software Features | Real-time foam height tracking, algorithmic foam volume quantification, manual result override, full-test video recording |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | aqua 40.00 |
| Measurement Range | 1 µg – 100 mg |
| Resolution | 0.1 µg |
| Repeatability | ±3 µg (for 10–1000 µg water) |
| Temperature Control Range | 35 °C – 300 °C |
| Power Supply | 230 V |
| Sample Introduction | Optional automated sample changer |
| Gas System | Closed-loop, carrier-gas-free dynamic headspace |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software support |
| Brand | Checkfluid |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LP Series |
| Pricing | Upon Request |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ABL-8 |
| Test Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 21789, IP 170, ISO 13736, ISO 1516, ISO 1523 |
| Temperature Range | −30 °C to +80 °C |
| Ignition System | Dual-mode (Gas Flame & Electric Spark) |
| Repeatability | High |
| Cooling Method | Peltier-based Semiconductor Cooling |
| Display | 5.7-inch Color LCD |
| Data Storage Capacity | 200 Test Records |
| Atmospheric Pressure Compensation | Integrated Barometric Sensor |
| Safety Features | Auto Fire Suppression, Fault Diagnostics, Wind Shield Enclosure |
| Compliance Support | ASTM D3278, ISO/IEC 17025 Traceability Framework, GLP Audit Trail Ready |