- All
- Favorite
- Popular
- Most rated
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A3 / 2DMax1100P3 |
| Price | Upon Request |
| Pump Flow Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-Vis Detector Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P3 only) | 160-tube rack, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SpeedMembrand-10 |
| Automation Level | Fully Automatic |
| Channel Configuration | Multi-channel (1/4/6/8 selectable) |
| Extraction Method | Membrane-based Solid Phase Extraction (SPE) |
| Flow Rate Range | 0–200 mL/min |
| Sample Volume Capacity | >2 L |
| Available Membrane Diameters | 47 mm, 50 mm, 90 mm |
| Compatibility | Designed for integration with KEZHE’s fully automated SPE systems |
| Material in Contact with Solvents | Chemically resistant polymer housing and fluidic path (e.g., PTFE, PEEK, or equivalent inert materials per standard SPE accessory design) |
| Structural Flexibility | Modular channel expansion/reduction capability |
| Dual-mode Support | Compatible with both cartridge-based and disk-type membrane SPE formats |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NooneLost-2000 |
| Instrument Type | Fully Automated Colony Counter |
| Counting Speed | >400 Petri Dishes per Hour |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | VNH-300 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity per Channel | 250 mL |
| Final Volume Setpoint Range | 0–1 mL |
| Heating Method | Dry Block Heating |
| Number of Channels | 6 |
| Maximum Gas Flow per Channel | 10 L/min |
| Control Interface | Touchscreen HMI |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | TLC Densitometer |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence, Chemiluminescence |
| Wavelength Range | 190–900 nm (continuously adjustable) |
| Light Sources | Tungsten-halogen lamp, Deuterium lamp, Mercury lamp (auto-switching) |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (user-selectable |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (fully automated control) |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates (customizable up to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VNH-500 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ≤ 0.5 °C |
| Sample Capacity per Vial | 10–80 mL |
| Maximum Simultaneous Samples | 72 (customizable) |
| Gas Flow Rate | Up to 15 L/min (N₂ or inert gas) |
| Heating Method | Water Bath |
| Operating Modes | Manual / Method-Based / Timer-Based |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | TLC Scanner |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence, Chemiluminescence |
| Wavelength Range | 190 nm – 1000 nm |
| Light Sources | Tungsten-Halogen Lamp, Deuterium Lamp, Mercury Lamp (Auto-Switching) |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Function |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (Selectable) |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Reproducibility | < 0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (Fully Automated Control) |
| Sample Stage | Accommodates 200 mm × 200 mm TLC plates (customizable to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| A/D Converter | 24-bit, 8-channel, 20 µs dual conversion |
| Slit Dimensions | Length 0–8 mm, Width 0–4 mm (Continuously Variable, PC-Controlled) |
| Fluorescence Filters | Standard set of six (K320, K360, K400, K450, K510, K550) |
| Detector | Photomultiplier Tube (PMT) |
| Data Acquisition Rate | 30,000 data points per second |
| Communication Interface | USB 2.0 |
| Compliance | Fully supports 21 CFR Part 11, electronic signatures, and IQ/OQ/PQ validation protocols |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriSmart-100 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0–50.00 mL/min (per pump) |
| Maximum Operating Pressure | 30 MPa |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.1 mAU (at 254 nm) |
| Baseline Drift | 0.2 mAU/h (at 254 nm) |
| Detection Modes | Dual-Wavelength UV-VIS, Online UV-VIS Spectral Scanning |
| Gradient Capability | Binary, Low-Delay Mixing |
| Fraction Collection | X-Y Robotic Fraction Collector |
| Software Compliance | Audit Trail, User Management, Data Integrity per FDA 21 CFR Part 11 & GLP Principles |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-ZY10E |
| Instrument Type | Fluorescence Detector-Compatible Post-Column Derivatization System |
| Temperature Range | Ambient to 150 °C |
| Temperature Accuracy | ±0.25 °C |
| Temperature Resolution | ±0.1 °C |
| Derivatization Pump Flow Rate | 0–10 mL/min |
| Flow Repeatability | ±0.1% |
| Reaction Coil Length | 10 m |
| Reactor Configuration | Modular, Single or Dual Cartridge Options |
| Mixing Architecture | Sealed Continuous-Loop Multi-Directional Flow Reactor |
| Peak Broadening Reduction | Optimized via Low-Dispersion Reaction Core Design |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriSmart-200 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Range | 0–30 MPa |
| Pressure Pulsation | < ±0.2 MPa |
| Wavelength Range | 190–850 nm (dual-wavelength simultaneous detection) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ±0.1 mAU at 254 nm |
| Baseline Drift | 0.2 mAU/30 min at 254 nm |
| Sample Injection Volume | 5 mL (standard), customizable |
| Detector Light Source | Deuterium–Tungsten dual-lamp assembly |
| Monochromator | 1200-line/mm holographic grating |
| Fraction Collection | X-Y matrix-type collector |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–6 / 12 (standard), up to 48 (customizable) |
| Final Absolute Vacuum | 30 mbar |
| Solvent Recovery | Integrated Condensation System |
| Vacuum Pump Flow Rate | 30 L/min |
| Cooling Circulator Range | 10 °C to Ambient |
| Programmable Temperature Profile | 6-step, 0–10 h per step |
| Vortex Agitation Speed | 0–250 rpm |
| Tail-tube Volumes | 0.3 / 1 / 3 mL |
| Heating Method | Selectable Metal Bath or Water Bath |
| Power Supply | 220–240 V, 50/60 Hz, Max 2200 W |
| Control Interface | PC-based Software with Audit Trail |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ScalePuri-100 |
| Application Level | Laboratory & Pilot-Scale |
| Instrument Type | Medium-to-High Pressure Preparative LC |
| Flow Rate Range | 0–100 mL/min (pump), up to 800 mL/min (gradient mixing) |
| Flow Accuracy | RSD = 0.5% |
| Flow Precision | RSD = 1% |
| Max Operating Pressure | 150 bar |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Detection Mode | UV-VIS with Quad-Wavelength Real-Time Monitoring |
| Column Compatibility | Axial Compression Columns, 50–100 mm ID |
| Prep Capacity | Gram-scale (up to 100 g per run) |
| System Control | Fully Software-Driven with Audit Trail, User Management, and Electronic Signature Support |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FlashDoctor-1000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–120 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Rating | 145 psi (1.0 MPa) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU @ 254 nm |
| Fraction Collection | X-Y Robotic Matrix with 135-tube Capacity (standard 15 × 150 mm tubes) |
| Detection Options | Dual-Wavelength UV Detector (D₂ + Tungsten lamp) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Vacuum Centrifugal Concentrator |
| Temperature Range | 10–40 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Maximum Sample Volume per Position | 120 mL |
| Sample Capacity | 1–6 parallel positions |
| Final Absolute Vacuum | 8 mbar |
| Cooling Circulator Range | −10 to +25 °C |
| Vacuum Pump Flow Rate | 3 L/min at 0.6 bar |
| Vacuum Pump Speed Control | Yes |
| Rotational Agitation | 0–600 rpm |
| Tail Tube Volumes Supported | 0.3, 1, or 3 mL |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | TH-II |
| Instrument Type | TLC Ancillary Equipment |
| Detection Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm), Nitrogen Purge Capable |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | 200 mm × 200 mm TLC Plate |
| Maximum Scan Speed | 100 mm/s |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ≤ ±1 °C |
| Heating Platform Dimensions | 300 mm × 250 mm |
| Power Supply | 220 V AC, 600 W |
| Heating Element | Cast-Aluminum Block with Uniform-Heat Plate |
| Construction | Stainless Steel Sample Tray, Digital PID Temperature Controller |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Semi-Automatic Colony Counter |
| Counting Speed | >400 samples/h |
| Country of Origin | Domestic (China) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Semi-Automated Colony Counter |
| Counting Speed | >50 Petri Dishes per Hour |
| Imaging Sensor | 12 MP |
| Illumination | Transmitted White Light |
| Compatible Dish Diameters | 60, 75, 90, 100, 120 mm |
| Software Features | Background Optimization, Manual Correction Mode, Adjustable Brightness/Contrast/Sensitivity, Auto-Edge Cropping, Individual Colony Tagging, Excel Export, Zone Diameter Measurement (for Kirby-Bauer & Cylinder Plate Assays) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GOODSPE-80 |
| Automation Level | Fully Automatic |
| Number of Channels | 8 |
| Extraction Mode | Column-Based SPE |
| Flow Rate Control Range | 0.01–15 mL/min |
| Solvent Selection | Up to 4 independent solvent lines |
| Sample Capacity | Simultaneous processing of up to 8 samples |
| Sample Loading Volume | 1–30 mL per channel |
| Wetted Materials | Stainless steel (316), PTFE, borosilicate glass, PEEK |
| Brand | KEZHE / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | PuriMaster-2000 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 1.0% |
| Maximum Pressure | 4000 PSI (27.6 MPa) |
| Wavelength Range | 190–850 nm (dual-wavelength simultaneous detection) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±3×10⁻⁵ AU (254 nm) |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TBOX-I |
| Instrument Category | TLC Auxiliary Equipment |
| Sample Plate Size | 200 × 200 mm |
| Airflow Capacity | 4000 L/min |
| Construction Materials | Stainless Steel Enclosure, Corrosion-Resistant Gas Conduit, Integrated Spray Stand |
| Noise Level | Low-Noise Operation |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory safety workflows |
| Software Interface | None (Standalone Mechanical System) |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-FL30E |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | 150 W DC Xenon Lamp |
| Spectral Bandwidth | 10 nm / 15 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Software | FM-2000 Chromatography Workstation |
| Compliance | Chinese Pharmacopoeia (2010 & 2015 Editions), GLP/GMP-ready, LIMS-compatible, FDA 21 CFR Part 11 support (audit trail & electronic signature enabled) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | KH-CTLC-III |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Instrument Type | Forced-Flow Centrifugal TLC System |
| Wavelength Range | 190–700 nm |
| Light Source | Dual-Wavelength UV Lamp (254 nm & 365 nm) |
| Detection Mode | Full-Spectrum UV Absorbance Detection |
| Sample Loading Capacity | 100 mg – 2 g per run |
| Rotational Speed | 100–1450 rpm |
| TLC Plate Diameter | 245 mm |
| Plate Thickness Options | 1, 2, 3, 4, 6, 8 mm |
| Flow Rate Range | 0–20 mL/min |
| Fraction Collection | X-Y Robotic Fraction Collector (120 positions, 15 mm test tubes) |
| Medium-Pressure Column | 15 × 400 mm glass column |
| Max. Operating Pressure | 0–50 kgf/cm² (0–4.9 MPa) |
| Plate Spinning Mechanism | CNC-Machined Precision Rotating Platform |
| Pump Type | Stepper-Motor-Driven Constant-Flow Peristaltic Pump |
| Integrated Sample Filtration | In-line Cartridge Filter for Adsorption Mitigation |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodLook-1000 |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light (400–700 nm) |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates |
| Maximum Scanning Speed | 100 mm/s |
| Camera Resolution | 12 MP |
| Exposure Time Range | 0–10 s |
| Gain Adjustment | 0–100% |
| Imaging Modalities | Visible, UV, Fluorescence, Chemiluminescence |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-30E |
| Instrument Category | TLC Sample Spotter |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | <1 nm |
| Wavelength Repeatability | <0.2 nm |
| Minimum Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Spotting Volume Range | 10 nL – 2 mL |
| Spotting Precision | ±1.25 nL (with 25 µL syringe) |
| Syringe Options | 10 µL, 25 µL (standard), 50 µL, 100 µL |
| X/Y/Axial Drive Resolution | 200 steps/mm (X), 400 steps/mm (Y), 3200 steps/mm (syringe) |
| Heating Stage Range | Ambient to 60 °C (±1 °C) |
| Heated Nozzle | 30–80 °C |
| Auto-sampler Capacity | 96 × 2 mL vials |
| Gas Supply | 0.4 MPa, N₂ or compressed air |
| Flow Rate | 2–3 L/min |