Empowering Scientific Discovery

Shanghai Kezhe Biochemical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
Model2DMax1100A3 / 2DMax1100P3
PriceUpon Request
Pump Flow Range0–200 mL/min (customizable higher flow available)
Maximum Pressure4000 psi with overpressure protection
UV-Vis Detector Wavelength Range190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm
Light SourceDeuterium lamp + Tungsten lamp
Autosampler Capacity144 vials (sealed vial design with needle wash function)
Fraction Collector (2DMax1100P3 only)160-tube rack, 15 mm tube diameter
Software PlatformWindows 7/10 (64-bit)
Communication InterfaceEthernet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeTLC Densitometer
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence, Chemiluminescence
Wavelength Range190–900 nm (continuously adjustable)
Light SourcesTungsten-halogen lamp, Deuterium lamp, Mercury lamp (auto-switching)
MonochromatorHolographic grating (1200 lines/mm) with nitrogen purge capability
Spectral Bandwidth5 nm / 10 nm / 20 nm (user-selectable
Wavelength Accuracy±0.5 nm
Wavelength Repeatability<0.1 nm
Minimum Spatial Resolution10–25 µm
Imaging Wavelengths254 nm, 365 nm, White Light (fully automated control)
Sample Stage CapacityAccommodates 200 mm × 200 mm TLC plates (customizable up to 300 mm × 200 mm)
Scan Speed0–120 mm/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Instrument TypeTLC Scanner
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence, Chemiluminescence
Wavelength Range190 nm – 1000 nm
Light SourcesTungsten-Halogen Lamp, Deuterium Lamp, Mercury Lamp (Auto-Switching)
MonochromatorHolographic Grating (1200 lines/mm) with Nitrogen Purge Function
Spectral Bandwidth5 nm / 10 nm / 20 nm (Selectable)
Wavelength Accuracy±0.5 nm
Wavelength Reproducibility< 0.1 nm
Minimum Spatial Resolution10–25 µm
Imaging Wavelengths254 nm, 365 nm, White Light (Fully Automated Control)
Sample StageAccommodates 200 mm × 200 mm TLC plates (customizable to 300 mm × 200 mm)
Scan Speed0–120 mm/s
A/D Converter24-bit, 8-channel, 20 µs dual conversion
Slit DimensionsLength 0–8 mm, Width 0–4 mm (Continuously Variable, PC-Controlled)
Fluorescence FiltersStandard set of six (K320, K360, K400, K450, K510, K550)
DetectorPhotomultiplier Tube (PMT)
Data Acquisition Rate30,000 data points per second
Communication InterfaceUSB 2.0
ComplianceFully supports 21 CFR Part 11, electronic signatures, and IQ/OQ/PQ validation protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelPuriSmart-100
Application LevelLaboratory-Scale R&D
Instrument TypeHigh-Pressure Preparative HPLC System
Flow Rate Range0–50.00 mL/min (per pump)
Maximum Operating Pressure30 MPa
Wavelength Range190–850 nm
Wavelength Accuracy±1 nm
Baseline Noise±0.1 mAU (at 254 nm)
Baseline Drift0.2 mAU/h (at 254 nm)
Detection ModesDual-Wavelength UV-VIS, Online UV-VIS Spectral Scanning
Gradient CapabilityBinary, Low-Delay Mixing
Fraction CollectionX-Y Robotic Fraction Collector
Software ComplianceAudit Trail, User Management, Data Integrity per FDA 21 CFR Part 11 & GLP Principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKezhe Shanghai
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelKH-ZY10E
Instrument TypeFluorescence Detector-Compatible Post-Column Derivatization System
Temperature RangeAmbient to 150 °C
Temperature Accuracy±0.25 °C
Temperature Resolution±0.1 °C
Derivatization Pump Flow Rate0–10 mL/min
Flow Repeatability±0.1%
Reaction Coil Length10 m
Reactor ConfigurationModular, Single or Dual Cartridge Options
Mixing ArchitectureSealed Continuous-Loop Multi-Directional Flow Reactor
Peak Broadening ReductionOptimized via Low-Dispersion Reaction Core Design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelPuriSmart-200
Application LevelLaboratory-Scale R&D
Instrument TypeHigh-Pressure Preparative HPLC System
Flow Rate Range0–100 mL/min
Flow Accuracy±1.5%
Pressure Range0–30 MPa
Pressure Pulsation< ±0.2 MPa
Wavelength Range190–850 nm (dual-wavelength simultaneous detection)
Wavelength Accuracy±1 nm
Wavelength Repeatability0.1 nm
Baseline Noise±0.1 mAU at 254 nm
Baseline Drift0.2 mAU/30 min at 254 nm
Sample Injection Volume5 mL (standard), customizable
Detector Light SourceDeuterium–Tungsten dual-lamp assembly
Monochromator1200-line/mm holographic grating
Fraction CollectionX-Y matrix-type collector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelScalePuri-100
Application LevelLaboratory & Pilot-Scale
Instrument TypeMedium-to-High Pressure Preparative LC
Flow Rate Range0–100 mL/min (pump), up to 800 mL/min (gradient mixing)
Flow AccuracyRSD = 0.5%
Flow PrecisionRSD = 1%
Max Operating Pressure150 bar
Wavelength Range190–850 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.2 nm
Baseline Noise3 × 10⁻⁵ AU
Data Acquisition Rate5 Hz
Detection ModeUV-VIS with Quad-Wavelength Real-Time Monitoring
Column CompatibilityAxial Compression Columns, 50–100 mm ID
Prep CapacityGram-scale (up to 100 g per run)
System ControlFully Software-Driven with Audit Trail, User Management, and Electronic Signature Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE Shanghai
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelFlashDoctor-1000
Application LevelLaboratory-Scale
Instrument TypeHigh-Pressure Preparative Liquid Chromatography System
Flow Rate Range0–120 mL/min
Flow Accuracy±1.5%
Pressure Rating145 psi (1.0 MPa)
Wavelength Range190–850 nm
Wavelength Accuracy±1 nm
Spectral Bandwidth8 nm
Baseline Noise±0.2 mAU @ 254 nm
Baseline Drift0.2 mAU @ 254 nm
Fraction CollectionX-Y Robotic Matrix with 135-tube Capacity (standard 15 × 150 mm tubes)
Detection OptionsDual-Wavelength UV Detector (D₂ + Tungsten lamp)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (China-made)
ModelTH-II
Instrument TypeTLC Ancillary Equipment
Detection ModesReflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence
Wavelength Range190–800 nm
Light SourcesXenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp
MonochromatorHolographic Grating (1200 lines/mm), Nitrogen Purge Capable
Spectral Bandwidth5 nm
Wavelength Accuracy< 1 nm
Wavelength Repeatability< 0.2 nm
Minimum Spatial Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White Light
Sample Stage Capacity200 mm × 200 mm TLC Plate
Maximum Scan Speed100 mm/s
Temperature Range0–200 °C
Temperature Accuracy≤ ±1 °C
Heating Platform Dimensions300 mm × 250 mm
Power Supply220 V AC, 600 W
Heating ElementCast-Aluminum Block with Uniform-Heat Plate
ConstructionStainless Steel Sample Tray, Digital PID Temperature Controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE / KEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
ModelPuriMaster-2000
Application LevelLaboratory-Scale R&D
Instrument TypeHigh-Pressure Preparative Liquid Chromatography System
Flow Rate Range0–100 mL/min
Flow AccuracyRSD ≤ 0.5%
Flow PrecisionRSD ≤ 1.0%
Maximum Pressure4000 PSI (27.6 MPa)
Wavelength Range190–850 nm (dual-wavelength simultaneous detection)
Wavelength Accuracy±1 nm
Wavelength Repeatability0.2 nm
Baseline Noise±3×10⁻⁵ AU (254 nm)
Data Acquisition Rate5 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelTBOX-I
Instrument CategoryTLC Auxiliary Equipment
Sample Plate Size200 × 200 mm
Airflow Capacity4000 L/min
Construction MaterialsStainless Steel Enclosure, Corrosion-Resistant Gas Conduit, Integrated Spray Stand
Noise LevelLow-Noise Operation
ComplianceDesigned for ISO/IEC 17025-aligned laboratory safety workflows
Software InterfaceNone (Standalone Mechanical System)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKezhe Shanghai
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelKH-FL30E
Instrument TypeFluorescence Detector (FD)
Wavelength Range190–900 nm (Excitation & Emission)
Measurement ModeDual-Beam
Light Source150 W DC Xenon Lamp
Spectral Bandwidth10 nm / 15 nm
Wavelength Accuracy±0.2 nm
Wavelength Precision±1 nm
Monochromator1200-line Holographic Grating
DetectorPhotomultiplier Tube (PMT)
AD/DA Resolution24-bit
Temperature Control Range (Flow Cell)Ambient to 50 °C
SoftwareFM-2000 Chromatography Workstation
ComplianceChinese Pharmacopoeia (2010 & 2015 Editions), GLP/GMP-ready, LIMS-compatible, FDA 21 CFR Part 11 support (audit trail & electronic signature enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelKH-CTLC-III
Price RangeUSD 7,000–14,000 (FOB Shanghai)
Instrument TypeForced-Flow Centrifugal TLC System
Wavelength Range190–700 nm
Light SourceDual-Wavelength UV Lamp (254 nm & 365 nm)
Detection ModeFull-Spectrum UV Absorbance Detection
Sample Loading Capacity100 mg – 2 g per run
Rotational Speed100–1450 rpm
TLC Plate Diameter245 mm
Plate Thickness Options1, 2, 3, 4, 6, 8 mm
Flow Rate Range0–20 mL/min
Fraction CollectionX-Y Robotic Fraction Collector (120 positions, 15 mm test tubes)
Medium-Pressure Column15 × 400 mm glass column
Max. Operating Pressure0–50 kgf/cm² (0–4.9 MPa)
Plate Spinning MechanismCNC-Machined Precision Rotating Platform
Pump TypeStepper-Motor-Driven Constant-Flow Peristaltic Pump
Integrated Sample FiltrationIn-line Cartridge Filter for Adsorption Mitigation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKezhe / KEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelGoodLook-1000
Instrument TypeTLC Imaging System
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence
Wavelength Range190–800 nm
Light SourcesXenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp
MonochromatorHolographic grating (1200 lines/mm) with nitrogen purge capability
Spectral Bandwidth5 nm
Wavelength Accuracy< 1 nm
Wavelength Repeatability< 0.2 nm
Minimum Spatial Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White light (400–700 nm)
Sample Stage CapacityAccommodates 200 mm × 200 mm TLC plates
Maximum Scanning Speed100 mm/s
Camera Resolution12 MP
Exposure Time Range0–10 s
Gain Adjustment0–100%
Imaging ModalitiesVisible, UV, Fluorescence, Chemiluminescence
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelSP-30E
Instrument CategoryTLC Sample Spotter
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence
Wavelength Range190–800 nm
Light SourcesXenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp
MonochromatorHolographic Grating (1200 lines/mm) with Nitrogen Purge Capability
Spectral Bandwidth5 nm
Wavelength Accuracy<1 nm
Wavelength Repeatability<0.2 nm
Minimum Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White Light
Sample Stage CapacityUp to 200 mm × 200 mm TLC Plates
Maximum Scanning Speed100 mm/s
Spotting Volume Range10 nL – 2 mL
Spotting Precision±1.25 nL (with 25 µL syringe)
Syringe Options10 µL, 25 µL (standard), 50 µL, 100 µL
X/Y/Axial Drive Resolution200 steps/mm (X), 400 steps/mm (Y), 3200 steps/mm (syringe)
Heating Stage RangeAmbient to 60 °C (±1 °C)
Heated Nozzle30–80 °C
Auto-sampler Capacity96 × 2 mL vials
Gas Supply0.4 MPa, N₂ or compressed air
Flow Rate2–3 L/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelTG-I
Price RangeUSD 140–700 (FOB Shanghai)
Instrument CategoryTLC Auxiliary Equipment
Cutting Platform Dimensions300 × 250 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Model2DMax1500A1 / 2DMax1500P1
TLC Plate Max Size200 × 200 mm
Laser Power5 mW
Sealing ForceUp to 500 N
Solvent Flow Rate (Extraction)0.05–0.3 mL/min
Extraction Probe OptionsØ4 mm, Ø5 mm circular
HPLC Flow Range0–100 mL/min (customizable)
Pressure Range0–10,000 psi (A1) / 0–4,000 psi (P1)
UV-VIS DetectionFour simultaneous wavelengths, 190–900 nm
Wavelength Accuracy±0.2 nm
Monochromator1200-line grating
Light SourceDeuterium–Tungsten dual lamp
Quantitation Loop20 µL (A1) / 2 mL (P1)
AutosamplerIntegrated
Fraction Collector Capacity160 positions
Gradient Composition0–100% linear A:B
Software PlatformWindows 7/8/10
Communication InterfaceEthernet
Power Supply110–220 V AC, 500 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelPuriMaster-7000
Application LevelLaboratory Grade
Instrument TypeHigh-Pressure Preparative Liquid Chromatograph
Flow Rate Range0–100 mL/min (customizable up to 200 mL/min)
Flow AccuracyRSD ≤ 0.5%
Flow PrecisionRSD ≤ 1.0%
Maximum Pressure4000 psi (27.6 MPa)
Wavelength Range190–850 nm (quad-wavelength simultaneous detection)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability±0.4 nm
Baseline Noise≤3 × 10⁻⁵ AU
Data Acquisition Rate5 Hz
Autosampler Capacity42 or 144 positions
Fraction Collector Capacity160 × 15 × 150 mm test tubes
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeConventional HPLC System
ModelAnters-1200E
Flow Rate Range0.001–5 mL/min
Maximum Pressure40 MPa
Sample Capacity144 × 2 mL vials
Injection Volume Range0.1–100 µL
Column Oven Temperature Range10–80 °C
UV-Vis Wavelength Range190–700 nm
Data Acquisition Rate100 Hz]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKezhe Shanghai
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelKH-FL50E
Instrument TypeFluorescence Detector (FD)
Excitation/Emission Wavelength Range190–900 nm
Detection ModesFluorescence, Phosphorescence, Chemiluminescence
Light Source150 W DC Xenon Lamp or 5 W Pulsed Xenon Lamp
Monochromator1200-line Holographic Grating
Spectral Bandwidth (Excitation & Emission)5/10/15/20 nm selectable
Wavelength Accuracy±0.2 nm
Wavelength Precision±1 nm
AD/DA Resolution24-bit
Flow Cell Temperature Control5–50 °C
Detector OptionsSingle-Photon Counting Module (SPCM) or Variable-Voltage High-Sensitivity PMT
ComplianceChinese Pharmacopoeia 2010/2015, GLP/GMP-ready, LIMS-compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelTM-200
Instrument TypeTLC–MS Interface
Measurement ModeTransmission Absorption
Wavelength Range190–800 nm
Light SourceLaser
Laser Power5 mW
Spectral Bandwidth5 nm
Wavelength Accuracy< 1 nm
Wavelength Repeatability< 0.2 nm
Minimum Spatial Resolution25 µm
Imaging Wavelength254 nm
Maximum TLC Plate Size200 × 200 mm
Solvent Flow Rate0.05–0.3 mL/min
Pneumatic SourceN₂ or Compressed Air
Sealing ForceUp to 500 N
Extraction Probe OptionsØ4 mm, Ø5 mm (circular), 4 × 2 mm (elliptical)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelUV+2000
Instrument TypeFluorescence Detector (FD) Compatible Derivatization Device
Wavelength Range195–600 nm
Measurement ModeDual-Beam
Light SourceXenon Lamp
Maximum Flow Rate2 mL/min (customizable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (PRC-Made)
ModelTK-II
Price RangeUSD 1,400 – 4,200 (FOB Shanghai)
Instrument TypeTLC Ancillary Equipment Suite
UV Wavelengths254 nm & 365 nm
Max Plate Size Supported200 × 200 mm
Min Plate Size Supported25 × 75 mm (development), 50 × 50 mm (storage)
Imaging PlatformIntegrated dark chamber with dual-band UV illumination
ResolutionSingle-band spectral isolation via fixed-wavelength UV lamps
Scan CapabilityVisual observation and photographic documentation only (no motorized scanning or densitometry)
Plate HandlingManual positioning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKezhe Shanghai
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelKH-FL30Plus
Instrument TypeFluorescence Detector (FD)
Wavelength Range190–900 nm (Excitation & Emission)
Wavelength Accuracy±0.2 nm
Wavelength Precision±1 nm
Spectral Bandwidth10 nm / 15 nm
Light Source150 W DC Xenon Lamp
Monochromator1200-line Holographic Grating
DetectorPhotomultiplier Tube (PMT)
AD/DA Resolution24-bit
Temperature Control RangeAmbient to 50 °C (Optional)
ComplianceChinese Pharmacopoeia 2010/2015 Edition, GLP/GMP-Ready, LIMS-Compatible
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0