- All
- Favorite
- Popular
- Most rated
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Aseeker-600 |
| Instrument Category | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 10 mL / 20 mL / 40 mL |
| Throughput | 6 samples in 20 min |
| Dimensions (W×D×H) | 770 mm × 608 mm × 755 mm |
| Weight | 95 kg |
| Solvent Consumption per Sample | 5–200 mL |
| Pump Flow Rate | 0.1–50 mL/min |
| Power Requirement | 100–240 VAC ±10 %, 50–60 Hz |
| Max Power Consumption | 1.7 kW |
| Gas Supply | Lab-grade nitrogen, 0.4–1 MPa |
| Solvent Mixing Capability | Up to 4 solvents |
| Collection Vial Capacity | 250 mL |
| Cleaning Stations | 6 |
| Sample Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Aseeker-100 |
| Instrument Category | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 11 mL / 22 mL / 33 mL |
| Collection Vial Capacities | 40 mL / 60 mL |
| Solvent Flow Rate | 0.1–50 mL/min |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Gas Supply Requirement | Nitrogen, 0.4–1 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max. Power Consumption | 600 W |
| Dimensions (W×D×H) | 450 mm × 500 mm × 530 mm |
| Weight | 30 kg |
| Sample Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection with automatic shutdown, liquid-level sensing with overflow prevention, integrated post-extraction filtration |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Aseeker-200 |
| Instrument Category | Solid-Liquid Extraction |
| Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Extraction Cell Volumes | 10 mL / 34 mL / 66 mL / 100 mL |
| Extraction Time | 20–30 min |
| Solvent Consumption | 10 mL per 10 g sample |
| Pump Flow Rate | 0.1–50 mL/min |
| Collection Vial Capacities | 60 mL / 250 mL |
| Gas Supply Requirement | Nitrogen at 0.9–1.2 MPa |
| Power Input | 100–240 VAC ±10 %, 50–60 Hz |
| Max Power Consumption | 1.2 kW |
| Dimensions (W×D×H) | 508 mm × 485 mm × 745 mm |
| Weight | 40 kg |
| Wetted Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Mechanical overpressure protection, electronic overtemperature cutoff, leak detection, liquid-level sensing, pressure-deficiency alarm, automatic filtration post-extraction, dual-needle purge system to prevent splashing |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Aseeker-500 |
| Instrument Type | Solid-Liquid Extraction System |
| Temperature Range | Ambient to 200 °C (±0.5 °C) |
| Pressure Range | 10 MPa (±0.5 MPa) |
| Extraction Cell Volume | Standard 34 mL (optional: 1, 5, 10, 22, 66, 100 mL) |
| Extraction Time per Sample | 20 min |
| Instrument Dimensions | 800 mm × 738 mm × 685 mm |
| Sample Capacity | 24 extraction cells |
| Collection Vials | Standard 19 × 250 mL or up to 28 × 60 mL + 5 × 250 mL with adapter |
| Pump Flow Rate | 0.1–50 mL/min |
| Power Consumption | ≤1.2 kW |
| Input Voltage | 100–240 VAC ±10 %, 50–60 Hz |
| Solvent Mixing Capability | Up to 4 solvents |
| Cleaning Stations | 2 |
| Weight | 70 kg |
| Contact Materials | PEEK, PTFE, 316L stainless steel, ceramic |
| Safety Features | Electronic over-pressure/over-temperature protection, leak detection with automatic shutdown and sequence bypass, external air supply pressure monitoring, infrared liquid-level sensing at collection vials |