Empowering Scientific Discovery

Shanghai Kezhe Biochemical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeTLC Densitometer
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence, Chemiluminescence
Wavelength Range190–900 nm (continuously adjustable)
Light SourcesTungsten-halogen lamp, Deuterium lamp, Mercury lamp (auto-switching)
MonochromatorHolographic grating (1200 lines/mm) with nitrogen purge capability
Spectral Bandwidth5 nm / 10 nm / 20 nm (user-selectable
Wavelength Accuracy±0.5 nm
Wavelength Repeatability<0.1 nm
Minimum Spatial Resolution10–25 µm
Imaging Wavelengths254 nm, 365 nm, White Light (fully automated control)
Sample Stage CapacityAccommodates 200 mm × 200 mm TLC plates (customizable up to 300 mm × 200 mm)
Scan Speed0–120 mm/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Instrument TypeTLC Scanner
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence, Chemiluminescence
Wavelength Range190 nm – 1000 nm
Light SourcesTungsten-Halogen Lamp, Deuterium Lamp, Mercury Lamp (Auto-Switching)
MonochromatorHolographic Grating (1200 lines/mm) with Nitrogen Purge Function
Spectral Bandwidth5 nm / 10 nm / 20 nm (Selectable)
Wavelength Accuracy±0.5 nm
Wavelength Reproducibility< 0.1 nm
Minimum Spatial Resolution10–25 µm
Imaging Wavelengths254 nm, 365 nm, White Light (Fully Automated Control)
Sample StageAccommodates 200 mm × 200 mm TLC plates (customizable to 300 mm × 200 mm)
Scan Speed0–120 mm/s
A/D Converter24-bit, 8-channel, 20 µs dual conversion
Slit DimensionsLength 0–8 mm, Width 0–4 mm (Continuously Variable, PC-Controlled)
Fluorescence FiltersStandard set of six (K320, K360, K400, K450, K510, K550)
DetectorPhotomultiplier Tube (PMT)
Data Acquisition Rate30,000 data points per second
Communication InterfaceUSB 2.0
ComplianceFully supports 21 CFR Part 11, electronic signatures, and IQ/OQ/PQ validation protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (China-made)
ModelTH-II
Instrument TypeTLC Ancillary Equipment
Detection ModesReflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence
Wavelength Range190–800 nm
Light SourcesXenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp
MonochromatorHolographic Grating (1200 lines/mm), Nitrogen Purge Capable
Spectral Bandwidth5 nm
Wavelength Accuracy< 1 nm
Wavelength Repeatability< 0.2 nm
Minimum Spatial Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White Light
Sample Stage Capacity200 mm × 200 mm TLC Plate
Maximum Scan Speed100 mm/s
Temperature Range0–200 °C
Temperature Accuracy≤ ±1 °C
Heating Platform Dimensions300 mm × 250 mm
Power Supply220 V AC, 600 W
Heating ElementCast-Aluminum Block with Uniform-Heat Plate
ConstructionStainless Steel Sample Tray, Digital PID Temperature Controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelTBOX-I
Instrument CategoryTLC Auxiliary Equipment
Sample Plate Size200 × 200 mm
Airflow Capacity4000 L/min
Construction MaterialsStainless Steel Enclosure, Corrosion-Resistant Gas Conduit, Integrated Spray Stand
Noise LevelLow-Noise Operation
ComplianceDesigned for ISO/IEC 17025-aligned laboratory safety workflows
Software InterfaceNone (Standalone Mechanical System)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelKH-CTLC-III
Price RangeUSD 7,000–14,000 (FOB Shanghai)
Instrument TypeForced-Flow Centrifugal TLC System
Wavelength Range190–700 nm
Light SourceDual-Wavelength UV Lamp (254 nm & 365 nm)
Detection ModeFull-Spectrum UV Absorbance Detection
Sample Loading Capacity100 mg – 2 g per run
Rotational Speed100–1450 rpm
TLC Plate Diameter245 mm
Plate Thickness Options1, 2, 3, 4, 6, 8 mm
Flow Rate Range0–20 mL/min
Fraction CollectionX-Y Robotic Fraction Collector (120 positions, 15 mm test tubes)
Medium-Pressure Column15 × 400 mm glass column
Max. Operating Pressure0–50 kgf/cm² (0–4.9 MPa)
Plate Spinning MechanismCNC-Machined Precision Rotating Platform
Pump TypeStepper-Motor-Driven Constant-Flow Peristaltic Pump
Integrated Sample FiltrationIn-line Cartridge Filter for Adsorption Mitigation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKezhe / KEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelGoodLook-1000
Instrument TypeTLC Imaging System
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence
Wavelength Range190–800 nm
Light SourcesXenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp
MonochromatorHolographic grating (1200 lines/mm) with nitrogen purge capability
Spectral Bandwidth5 nm
Wavelength Accuracy< 1 nm
Wavelength Repeatability< 0.2 nm
Minimum Spatial Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White light (400–700 nm)
Sample Stage CapacityAccommodates 200 mm × 200 mm TLC plates
Maximum Scanning Speed100 mm/s
Camera Resolution12 MP
Exposure Time Range0–10 s
Gain Adjustment0–100%
Imaging ModalitiesVisible, UV, Fluorescence, Chemiluminescence
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelSP-30E
Instrument CategoryTLC Sample Spotter
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence
Wavelength Range190–800 nm
Light SourcesXenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp
MonochromatorHolographic Grating (1200 lines/mm) with Nitrogen Purge Capability
Spectral Bandwidth5 nm
Wavelength Accuracy<1 nm
Wavelength Repeatability<0.2 nm
Minimum Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White Light
Sample Stage CapacityUp to 200 mm × 200 mm TLC Plates
Maximum Scanning Speed100 mm/s
Spotting Volume Range10 nL – 2 mL
Spotting Precision±1.25 nL (with 25 µL syringe)
Syringe Options10 µL, 25 µL (standard), 50 µL, 100 µL
X/Y/Axial Drive Resolution200 steps/mm (X), 400 steps/mm (Y), 3200 steps/mm (syringe)
Heating Stage RangeAmbient to 60 °C (±1 °C)
Heated Nozzle30–80 °C
Auto-sampler Capacity96 × 2 mL vials
Gas Supply0.4 MPa, N₂ or compressed air
Flow Rate2–3 L/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelTG-I
Price RangeUSD 140–700 (FOB Shanghai)
Instrument CategoryTLC Auxiliary Equipment
Cutting Platform Dimensions300 × 250 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelTM-200
Instrument TypeTLC–MS Interface
Measurement ModeTransmission Absorption
Wavelength Range190–800 nm
Light SourceLaser
Laser Power5 mW
Spectral Bandwidth5 nm
Wavelength Accuracy< 1 nm
Wavelength Repeatability< 0.2 nm
Minimum Spatial Resolution25 µm
Imaging Wavelength254 nm
Maximum TLC Plate Size200 × 200 mm
Solvent Flow Rate0.05–0.3 mL/min
Pneumatic SourceN₂ or Compressed Air
Sealing ForceUp to 500 N
Extraction Probe OptionsØ4 mm, Ø5 mm (circular), 4 × 2 mm (elliptical)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic (PRC-Made)
ModelTK-II
Price RangeUSD 1,400 – 4,200 (FOB Shanghai)
Instrument TypeTLC Ancillary Equipment Suite
UV Wavelengths254 nm & 365 nm
Max Plate Size Supported200 × 200 mm
Min Plate Size Supported25 × 75 mm (development), 50 × 50 mm (storage)
Imaging PlatformIntegrated dark chamber with dual-band UV illumination
ResolutionSingle-band spectral isolation via fixed-wavelength UV lamps
Scan CapabilityVisual observation and photographic documentation only (no motorized scanning or densitometry)
Plate HandlingManual positioning
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelTU-II
Price RangeUSD 140 – 700 (FOB)
Instrument TypeTLC Auxiliary Equipment
UV Wavelengths254 nm & 365 nm
Max Sample Size200 × 200 mm TLC Plate
DesignPortable, Light-Tight Enclosure
UV Lamp ConfigurationDual-Wavelength Integrated Fluorescent Lamps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKezhe / KEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelGoodLook-2000
Instrument TypeTLC Imaging System
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence
Wavelength Range190–800 nm
Light SourcesXenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp
MonochromatorHolographic grating (1200 lines/mm) with nitrogen purge capability
Spectral Bandwidth5 nm
Wavelength Accuracy< 1 nm
Wavelength Repeatability< 0.2 nm
Minimum Spatial Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White light (400–700 nm)
Sample Stage CapacityUp to 200 mm × 200 mm TLC plates
Scanning SpeedMax 100 mm/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelKH-2300
Instrument TypeTLC Scanner
Operation ModeFully Automatic
Measurement ModesReflectance, Fluorescence (optional), Absorbance
Wavelength Range190–700 nm (automatically programmable)
Light SourceDeuterium Lamp + Tungsten Halogen Lamp
MonochromatorHolographic Grating
Spectral Bandwidth5 nm
Wavelength Accuracy≤ ±1 nm
Wavelength RepeatabilityRSD ≤ 2.0%
Minimum Spatial Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White Light
Sample Stage CapacityUp to 20 × 30 cm TLC plates of arbitrary thickness
Scanning Speed0–50 mm/s
Auto-sampler Capacity96 × 2 mL vials
Minimum Spot Volume10 nL
Spotting ModesCircular, Band, Square
Band Length Range5–195 mm
Heating Base Temperature Range30–60 °C (±1 °C)
Optional AccessoriesTS-II Dual-Nozzle Electrospray Nebulizer, TD-II Automated TLC Plate Coater, TK-10 Electronic Development Chamber
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelSP-II
Instrument CategoryTLC Sample Spotter
Sample Application ModesCircular Spot & Linear Band
Spotting Range0–200 mm
Spotting Temperature RangeAmbient to 100 °C
Heating Platform Temperature RangeAmbient to 200 °C
Heating SystemCNC Digital Display Heated Stage with Uniform Heat Distribution Plate
Drive MechanismHigh-Reliability Shanghai Brand Stepper Motor Assembly
Spotting PrecisionContact-Based, Non-Sticking Needle Interface
ComplianceDesigned for GLP-aligned laboratory workflows and compatible with ISO 17025 traceability requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelTY-10
Instrument CategoryTLC Auxiliary Equipment
Maximum Plate Size200 × 100 mm (standard), 200 × 200 mm (customizable)
Immersion Speed0–10 mm/s (adjustable)
Configuration IncludesReagent Reservoir Tank, Main Derivatization Unit, TLC Plate Holder Assembly, Dedicated Control Software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelTD-I
Plate Width Compatibility50 mm, 100 mm, 200 mm
Adjustable Coating Thickness Range0–2.5 mm
Plate Size SupportStandard 200 mm × 200 mm (customizable to 300 mm × 200 mm)
ConstructionCNC-machined stainless steel and anodized aluminum components
IncludesMulti-size carrier tray, adjustable slurry reservoir, integrated mini slurry homogenizer, precision thickness gauge
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelTS-20E
Operation ModeFully Automatic
Measurement ModesReflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence
Wavelength Range190–800 nm
Light SourcesXenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp
MonochromatorHolographic Grating (1200 lines/mm) with Nitrogen Purge Capability
Spectral Bandwidth5 nm
Wavelength Accuracy< 1 nm
Wavelength Repeatability< 0.2 nm
Minimum Spatial Resolution25 µm
Imaging Wavelengths254 nm, 365 nm, White Light
Sample Stage CapacityAccommodates TLC Plates up to 200 mm × 200 mm
Maximum Scanning Speed100 mm/s
Syringe Volume Range0.2–10 mL
Liquid Handling Speed0.1–25 mL/min (Aspiration/Dispense/Clean)
Pre-spray Area (X/Y)0–100 mm / 0–200 mm
Full Spray Area (X/Y)0–200 mm / 0–200 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelTB-2
Price RangeUSD 140–700 (FOB)
Instrument TypeTLC Scanner Accessory
Wavelength Range190–700 nm (multi-band selectable)
Calibration WavelengthsUV 254 nm, UV 365 nm, and White Light
Plate Size Capacity50 × 50 mm to 200 × 200 mm
AdjustabilityHorizontal Leveling ±0.1°, Width Adjustment Range: 50–220 mm
ConstructionAnodized Aluminum Frame with Tempered Glass Doors & Stainless Steel Shelves
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeManufacturer
ModelTD-II
Plate Thickness Range0–3 mm (continuously adjustable)
Plate Width Options100 mm & 200 mm
Coating Cycle Time≤10 seconds per plate
Single-Batch Capacity4×(200×200 mm), 8×(200×100 mm), or 16×(100×100 mm) plates
Power Supply220 V, 50 Hz, 10 W (main unit only)
ConstructionStainless steel frame and wetted components
ComplianceDesigned to meet Chinese Pharmacopoeia 2015 Edition requirements for quantitative TLC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeForced-Flow Centrifugal TLC System
UV Wavelengths254 nm & 365 nm
UV SourceDual-Band UV Lamp
Separation Capacity100 mg – 2 g per run
Rotational Speed Range100 – 1450 rpm
Plate Diameter245 mm
Adsorbent Layer Thickness Options1, 2, 3, 4, 6, 8 mm
Solvent Consumption< 350 mL per separation
Reusable PlatesYes
Gradient Elution CapabilityOn-line, programmable via manual valve control
Plate Preparation IncludedYes (with scraper & plate former)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelGoodSee-20E
Instrument TypeTLC Imaging System
Imaging Wavelengths254 nm UV, 365 nm UV, Visible Light
Maximum Imaging Area200 × 200 mm
Camera Resolution≥12 MP
Power Supply220 V, 50 Hz, 90 W
Light Source Power30 W per channel
Scanning SpeedUp to 100 mm/s
InterfaceUSB
Software PlatformWindows 7 / 10
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelKH-3000
Instrument CategoryTLC Scanner
Wavelength Range190–900 nm (continuously adjustable)
Light SourcesDeuterium lamp & tungsten-halogen lamp (auto-switching)
MonochromatorHolographic grating (1200 lines/mm)
Spectral Bandwidth10 nm
Wavelength Accuracy±0.5 nm
Minimum Resolution25–50 µm
Sample StageAccommodates 200 mm × 200 mm TLC plates
Scan Speed0–120 mm/s
Detection ModesAbsorbance & optional Fluorescence
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeTLC Scanner
Operation ModeFully Automatic
Measurement ModesReflectance, Fluorescence (optional), Absorbance
Wavelength Range190–700 nm (auto-configurable)
Light SourceDeuterium Lamp + Tungsten-Halogen Lamp
MonochromatorHolographic Grating
Spectral Bandwidth5 nm
Wavelength Accuracy≤ ±1 nm
Wavelength RepeatabilityRSD ≤ 2.0%
Minimum Spatial Resolution25 µm
Imaging Wavelength Range190–700 nm
Sample Stage CapacityAccommodates 200 mm × 200 mm TLC plates
Maximum Scan Speed100 mm/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelSP-I
Instrument CategoryTLC Sample Spotter
Spotting Uniformity< 0.2 mm
Maximum Plate Size200 mm × 200 mm
Spotting MechanismCapillary or Microsyringe-Based Manual Deposition
Plate Protection FeatureNon-penetrating Tip Design
ComplianceDesigned for GLP-aligned manual sample preparation workflows