- All
- Favorite
- Popular
- Most rated
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-3000 |
| Flow Rate | 0–10 mL/min |
| Max Pressure | 1 psi |
| Flow Stability | ±0.5% RSD |
| Auto-sampler Volume | 5 mL (standard loop, customizable) |
| Auto-sampler Capacity | 160 × 20 mL tubes (standard) |
| UV Detection Range | 190–800 nm |
| Column Dimensions | 20 × 300 mm |
| Packing Material | Bio-Beads S-X3 (200–400 mesh) |
| Solvent System | Ethyl Acetate/Cyclohexane (3:7 v/v) |
| Fraction Collector Options | 20 mL (160-position), 80 mL (40-position), 150 mL (12-position), 250–300 mL (8-position) |
| Solvent Recovery Valve | Integrated three-way valve for solvent recycling |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-1000 |
| Flow Rate Range | 0–10 mL/min |
| UV Detection Wavelength | 254 nm |
| Column Dimensions | 25 × 400 mm |
| Packing Material | Bio-Beads S-X3, 200–400 mesh |
| Solvent System | Ethyl Acetate–Cyclohexane (1:1 v/v) |
| Standard Loop Volume | 5 mL |
| Pump Type | Precision Plunger Pump |
| Detector Type | Single-Wavelength UV Detector |
| Sample Introduction | Manual Injection Valve with Solvent Recovery Three-Way Valve |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528, S-19, S35L00.00-34 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-4000 |
| Flow Rate | 0–50 mL/min |
| Auto-sampler Volume | 5 mL standard loop (customizable), 66-position 20 mL vial tray |
| Fraction Collector Capacity | 96-position 60 mL vial tray (customizable) |
| UV Detection Wavelength Range | 190–800 nm |
| GPC Column | 20 × 300 mm, Bio-Beads S-X3 (200–400 mesh), eluent: ethyl acetate/cyclohexane (3:7, v/v) |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528, S-19, S35L00.00-34 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GelMaster-2000 |
| Flow Rate Range | 0–10 mL/min |
| Maximum Pressure | Not Specified |
| Flow Stability | High (Dual-Piston Pump Architecture) |
| UV Detector Wavelength Range | 190–800 nm |
| GPC Column | 20 × 300 mm, Bio-Beads S-X3 (200–400 mesh), Eluent: Ethyl Acetate/Cyclohexane (3:7 v/v) |
| Fraction Collector | Standard 160-position rack for 20 mL tubes |
| Compliance | AOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528 |
Show next