Empowering Scientific Discovery

Shanghai Kezhe Biochemical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelGelMaster-3000
Flow Rate0–10 mL/min
Max Pressure1 psi
Flow Stability±0.5% RSD
Auto-sampler Volume5 mL (standard loop, customizable)
Auto-sampler Capacity160 × 20 mL tubes (standard)
UV Detection Range190–800 nm
Column Dimensions20 × 300 mm
Packing MaterialBio-Beads S-X3 (200–400 mesh)
Solvent SystemEthyl Acetate/Cyclohexane (3:7 v/v)
Fraction Collector Options20 mL (160-position), 80 mL (40-position), 150 mL (12-position), 250–300 mL (8-position)
Solvent Recovery ValveIntegrated three-way valve for solvent recycling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelGelMaster-1000
Flow Rate Range0–10 mL/min
UV Detection Wavelength254 nm
Column Dimensions25 × 400 mm
Packing MaterialBio-Beads S-X3, 200–400 mesh
Solvent SystemEthyl Acetate–Cyclohexane (1:1 v/v)
Standard Loop Volume5 mL
Pump TypePrecision Plunger Pump
Detector TypeSingle-Wavelength UV Detector
Sample IntroductionManual Injection Valve with Solvent Recovery Three-Way Valve
ComplianceAOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528, S-19, S35L00.00-34
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelGelMaster-4000
Flow Rate0–50 mL/min
Auto-sampler Volume5 mL standard loop (customizable), 66-position 20 mL vial tray
Fraction Collector Capacity96-position 60 mL vial tray (customizable)
UV Detection Wavelength Range190–800 nm
GPC Column20 × 300 mm, Bio-Beads S-X3 (200–400 mesh), eluent: ethyl acetate/cyclohexane (3:7, v/v)
ComplianceAOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528, S-19, S35L00.00-34
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEZHE SHANGHAI
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelGelMaster-2000
Flow Rate Range0–10 mL/min
Maximum PressureNot Specified
Flow StabilityHigh (Dual-Piston Pump Architecture)
UV Detector Wavelength Range190–800 nm
GPC Column20 × 300 mm, Bio-Beads S-X3 (200–400 mesh), Eluent: Ethyl Acetate/Cyclohexane (3:7 v/v)
Fraction CollectorStandard 160-position rack for 20 mL tubes
ComplianceAOAC 984.21, EPA SW-846 Method 3640A, FDA 2905A, EN 12393, EN 1528
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0