| [Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200E |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Capacity | 144 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | 10–80 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz] |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Aseeker-350Plus |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Temperature Control Range | 10–50 °C |
| Wavelength Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Cell Volume (Standard) | 120 mL |
| Pressure Accuracy | ±0.3 MPa |
| Temperature Accuracy | ±0.5 °C |
| Solvent Channels | 4 |
| Simultaneous Extraction Positions | 5 |
| Extraction Time per Batch (5 samples) | ≤20 min |
| Power Consumption | ≤1.7 kW |
| Gas Supply Requirement | N₂, 0.4–1 MPa |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200V |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Tray Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20 °C to 100 °C |
| UV-Vis Wavelength Range | 190–850 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | FlashDoctor-2500 |
| Instrument Type | Fast Liquid Chromatography System |
| Application Scope | General-purpose |
| Flow Rate Range | 0–200 mL/min |
| Maximum Pressure | 5 MPa |
| Flow Accuracy | 0.1% RSD |
| Wavelength Range | 190–850 nm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aseeker-100Plus |
| Instrument Category | Fast Liquid Chromatography System |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure Rating | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Injection Vial Capacity | 2 mL |
| Temperature Control Range | 10–50 °C |
| Wavelength Detection Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Pump Flow Range | 0.1–50 mL/min |
| Standard Extraction Cell Volume | 40 mL (optional: 10 mL / 20 mL) |
| Standard Collection Vial Volume | 250 mL (optional: 60 mL) |
| Solvent Mixing Capability | Up to 4 solvents |
| Typical Extraction Duration | 20–30 min |
| Solvent Consumption | ~10 mL per 10 g sample |
| Required Gas Supply | Nitrogen, 0.4–1 MPa |
| Max Power Consumption | 600 W |
| Electrical Input | 100–240 VAC ±10%, 50–60 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200R |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | Standard 144 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20 °C to 100 °C |
| Refractive Index (RI) Detection Range | 1.00–1.75 RIU |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200F1 |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Tray Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20–100 °C |
| Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200F2 |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20–100 °C |
| Wavelength Range (Fluorescence Detector) | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | FlashDoctor-1500 |
| Instrument Type | Medium-Pressure Flash Chromatography System |
| Application Scope | General-Purpose Preparative Purification |
| Flow Rate Range | 0–200 mL/min |
| Maximum Operating Pressure | 200 psi (1.38 MPa) |
| Flow Accuracy | ±1.5% |
| Injection Capacity | Manual or Optional Autosampler |
| Injection Volume Range | 0.1–50 mL (via syringe or loop) |
| Temperature Control | Ambient-only (no active column oven) |
| Wavelength Range (DAD) | 200–800 nm |
| Data Acquisition Rate | Up to 20 Hz |