- All
- Favorite
- Popular
- Most rated
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MP523-03 |
| Price | USD 920 (FOB Shanghai) |
| Instrument Type | Multi-Ion Meter |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.002 pH |
| pH Temp. Compensation | 0–100 °C |
| pCa Range (Meter) | 0.00–9.00 pCa |
| pCa Range (with Electrode) | 1.00–7.00 pCa |
| pCa Accuracy | ±0.01 pCa |
| pCa Temp. Compensation | 0–50 °C |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | −10 to 110 °C |
| Temp. Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MP523-04 |
| Price | USD 920 (FOB Shanghai) |
| Instrument Type | Fluoride-Specific Ion Meter |
| pH Range | −2.000–19.999 |
| pH Accuracy | ±0.002 pH |
| Fluoride pF Range (Meter) | 0.00–9.00 pF |
| Fluoride pF Range (with Electrode Pair) | 1.00–7.00 pF |
| Fluoride Accuracy | ±0.01 pF |
| Temperature Compensation | 0–50 °C (for F⁻) |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temp. Range | −10–110 °C |
| Temp. Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| GLP Compliance | Yes |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Sodium Ion Analyzer |
| Measurement Range (Meter) | 0.00–9.00 pNa |
| (with配套 electrode system) | 1.00–7.00 pNa |
| Accuracy (Meter) | ±0.01 pX |
| (System) | ±0.02 pX |
| Temperature Range | −10 °C to 110 °C |
| Detection Limit (Static) | ≥2 ppb Na⁺ |
| (Dynamic) | ≥0.2 ppb Na⁺ |
| Units | pNa, mol/L, mg/L, ppm |
| Temperature Compensation | 0–50 °C |
| mV Range | ±1999.9 mV |
| Resolution | 0.1 mV |
| Accuracy | ±0.1% FS |
| Temp Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 entries |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture, supports audit-ready data logging |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Ion Measured | Fluoride (F⁻) |
| Measurement Range (Meter) | 0.00–9.00 pF |
| Measurement Range (with Electrode Pair) | 1.00–7.00 pF |
| Accuracy (Meter) | ±0.01 pF |
| Accuracy (Electrode System) | ±0.02 pF |
| Temperature Range | −10 °C to 110 °C |
| Temperature Compensation Range | 0 °C to 50 °C |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (other ranges) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant design, dust- and splash-resistant enclosure |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Fluoride Measurement Range | 1.00–6.00 pF |
| Detection Limit | 1.00–6.00 pF |
| Response Time | 5 s |
| Fluoride Accuracy | ±0.01 pF |
| Temperature Range | 0–80 °C |
| pH Range | 0.00–14.00 |
| pH Accuracy | ±0.01 |
| ORP Range | ±1999 mV |
| ORP Accuracy | ±0.1% FS |
| Data Storage | 200 sets |
| Power | 2 × AA batteries (1.5 V) |
| Dimensions (meter) | 65 × 120 × 31 mm |
| Weight (meter) | 180 g |
| IP Rating | IP57 |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | WS200 |
| Instrument Type | Portable |
| Fluoride Ion Measurement Range | 1.00–6.00 pF |
| Detection Limit | 1.00–6.00 pF |
| Response Time | 5 s |
| Fluoride Accuracy | ±0.01 pF |
| Temperature Range | 0–80 °C |
| pH Range | 0.00–14.00 |
| pH Accuracy | ±0.01 pH |
| ORP Range | ±1999 mV |
| ORP Accuracy | ±0.1% FS |
| Conductivity Range | 0–199.9 mS/cm |
| TDS Range | 0–100 g/L |
| Salinity Range | 0–100 ppt |
| Resistivity Range | 0–100 MΩ·cm |
| Conductivity Accuracy | ±1.0% of reading |
| Temperature Compensation | Automatic (0–80 °C for F⁻ |
| Electrode Constants | 0.1 / 1.0 / 10 cm⁻¹ |
| Reference Temperatures | 18 °C, 20 °C, 25 °C |
| Data Storage | 200 sets (ID, value, unit, temperature) |
| Power | 2 × AA batteries (1.5 V each) |
| Dimensions (meter) | 65 × 120 × 31 mm |
| Weight (meter) | 186 g |
| Carrying Case | 255 × 210 × 50 mm / 1.7 kg |
| Ingress Protection | IP57 |
| Brand | Sanxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | YD200 |
| Price | USD 560 (FOB Shanghai) |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) Method |
| Primary Analytes | Total Ca²⁺ and Mg²⁺ ions |
| Calibration Solutions | B1/B2/B3 standard buffers |
| Output Interface | RS232 serial port |
| Display | Backlit LCD with dual-unit real-time readout |
| Temperature Range | 0.0–60.0 °C (adjustable in °C/°F) |
| Hardness Units | mmol/L, mg/L (CaCO₃), mg/L (CaO), mmol/L (Boiler), mg/L (Ca) |
| GLP Compliance | Yes — automatic timestamped calibration logging, electrode history tracking, user ID support |
| Brand | Sanxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | MP523-02 |
| Ion Type | Sodium |
| Measurement Range (pNa) | 0.00–9.00 pNa (electrometer) |
| Detection Limit | ≥0.2 ppb (dynamic mode), ≥2 ppb (static mode) |
| Accuracy | ±0.01 pNa |
| Temperature Compensation | 0–50 °C |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture, supports audit-ready data logging |