- All
- Favorite
- Popular
- Most rated
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gr-Series |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Semi-Automatic |
| Digestion Positions | 8 / 20 / 36 |
| Temperature Range | Ambient to 650 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Principle | Infrared Radiation + High-Purity Graphite Conduction |
| Reagent Channels | 8 / 20 / 36 |
| Sample Capacity | ≤5 g (solid) or ≤25 mL (liquid) per tube |
| Digestion Tube Volume | 300 mL |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 3000 W |
| Dimensions (L×W×H) | 340×320×165 mm (8-position) / 420×380×220 mm (20- & 36-position) |
| Weight | 25 kg |
| Insulation | Ceramic Fiber + Air Gap + Forced-Air Channel Design |
| Corrosion Protection | Epoxy-Coated Housing + PTFE Spray Coating |
| Safety Features | Over-Temperature, Over-Current, Over-Voltage, Real-Time Fault Detection with Chinese-Language Display, Auto-Alarm & Shutdown |
| Exhaust Options | Two Configurable Acid Gas Absorption Systems |
| Compliance | Designed for ASTM D5179, ISO 11466, EPA Method 3050B, USP <231>, and GLP/GMP-aligned sample preparation workflows |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Model Variants | X08, X12, X20, X42, X56 |
| Digestion Capacity | 8 / 12 / 20 / 42 / 56 positions |
| Temperature Range | Ambient to 450 °C |
| Temperature Accuracy | ±1 °C |
| Heating Method | Integrated aluminum block resistive heating |
| Automation Level | Semi-automatic |
| Sample Vessel Compatibility | 100 mL and 300 mL digestion tubes |
| Max Sample Load | ≤6 g solid or ≤25 mL liquid |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 2400 W |
| Safety Certifications | ISO 9001 compliant |
| Housing Finish | PTFE-coated enclosure with corrosion-resistant isolation design and acid drainage channels |
| Thermal Insulation | Ceramic fiber + active air-channel cooling |
| Protection Features | Over-temperature, over-current, over-pressure, real-time sensor health monitoring, audible/visual alarm with Chinese-language status prompts |
| Brand | Sonnen |
|---|---|
| Model | ED20 |
| Origin | Shanghai, China |
| Application | Acidic corrosive gas absorption and neutralization in Kjeldahl digestion and wet chemical digestion processes |
| Sample Handling | Continuous waste gas treatment |
| Vacuum Flow Rate | 20 L/min (dual-head) |
| Ultimate Vacuum | 0.098 MPa |
| Construction Material | PTFE connectors throughout |
| Reagent Capacity | Up to 2 L |
| Power Consumption | 180 W |
| Electrical Supply | 220 V ±10%, 50 Hz |
| Water-Free Operation | Yes |
| Adjustable Vacuum Intensity | Yes |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Model | G100 |
| Extraction Chamber Volume | 600 mL |
| Receiving Flask Volume | 500 mL |
| Temperature Range | Ambient to 105 °C |
| Temperature Control Accuracy | ±1 °C |
| Batch Capacity | 10 samples per run |
| Filter Bag Pore Size | 3 µm |
| Solvent Recovery Rate | ≥90% |
| Sample Weight Range | 0.1–5 g |
| Analytical Range | 0.1–100% fat |
| Repeatability | ±0.2% |
| Extraction Time (per batch, excluding heating) | 60 min |
| Cooling Water Flow Rate | 4 L/min |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 500 W |
| Dimensions | 300 × 200 × 450 mm |
| Weight | 30 kg |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Model | G350 |
| Extraction Chamber Volume | 600 mL |
| Receiving Flask Volume | 500 mL |
| Temperature Range | Ambient to 105 °C |
| Temperature Control Accuracy | ±1 °C |
| Batch Capacity | 15 samples per run |
| Filter Bag Pore Size | 3 µm |
| Sample Mass Range | 0.1–5 g |
| Fat Determination Range | 0.1–100% |
| Solvent Recovery Rate | ≥90% |
| Repeatability | ±0.2% |
| Extraction Time (per batch, excluding heating) | 90 min |
| Solvent | Petroleum Ether (BP 30–60 °C) |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 500 W |
| Net Weight | 30 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | XH5K |
| Pricing | Available Upon Request |
| Temperature Range | 5–35 °C (at 20 °C ambient) |
| Temperature Stability | ±1 °C |
| Refrigeration Capacity | 1000 W |
| Max. Pump Flow Rate | 15 L/min |
| Max. Pump Discharge Pressure | 0.6–0.8 bar |
| Operation Mode | Continuous Duty |
| Pump Type | High-Performance Adjustable-Pressure Circulation Pump |
| Application Scope | Cooling & Temperature Stabilization for Small-Scale Analytical Instruments |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Model | S08 / S20 / S36 |
| Digestion Positions | 8 / 20 / 36 |
| Temperature Range | Ambient to 450 °C |
| Temperature Accuracy | ±1 °C |
| Heating Principle | Infrared Radiation + High-Purity Graphite Conduction |
| Automation Level | Fully Automatic |
| Digestion Vessel Capacity | 300 mL |
| Max Sample Mass | 6 g (solid) / 25 mL (liquid) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 3000 W |
| Dimensions (W×D×H) | 455 × 310 × 180 mm |
| Net Weight | 25 kg |
| Compliance | ISO 9001 Certified |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Model | Smart08 / Smart12 / Smart20 / Smart42 / Smart56 |
| Digestion Positions | 8 / 12 / 20 / 42 / 56 |
| Temperature Range | Ambient to 450 °C |
| Temperature Accuracy | ±1 °C |
| Heating Principle | Integrated Aluminum Block Heating |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Rated Power | 2400 W |
| Sample Capacity | ≤6 g solid or ≤25 mL liquid per tube |
| Digestion Tube Volume | 100 mL or 300 mL |
| Insulation Material | Ceramic fiber with air-channel thermal isolation |
| Safety Features | Over-temperature, over-current, over-pressure protection |
| Compliance | ISO 9001 certified |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Model | XA5K |
| Power Supply | 220 V AC, 50/60 Hz |
| Rated Power | 140 W |
| Airflow Capacity | 30 L/min |
| Application | Acidic Gas Scrubbing (e.g., NO₂, SO₂, HCl, HF), Compatible with Sonnen Digestion Systems |
| Construction | Corrosion-Resistant Housing, Removable Absorbent Cartridge Design |
| Compliance | Designed for laboratory-scale fume control per ISO 13857 and ANSI Z9.5 laboratory ventilation guidelines |
| Brand | Sonnen |
|---|---|
| Origin | Shanghai, China |
| Model | E-Series |
| Application | Acidic Exhaust Gas Treatment for Digestion Systems |
| Construction | PFA Sealing Lid with Corrosion-Resistant Collection Hood |
| Vacuum Source | Domestic Water-Operated Ejector Pump |
| Condensate Management | Integrated Acid-Resistant Drip Tray |
| Tubing Material | Imported High-Temperature/Acid-Resistant Polymer (e.g., PFA or ETFE) |
| Optional Integration | Compatible with ED20 Dual-Stage Scrubber Module |
Show next