Empowering Scientific Discovery

Shanghai Xufeng Scientific Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-1160
Standards ComplianceASTM D1160, GB/T 9168
Temperature Range0–400 °C (0.1 °C resolution)
Distillate Rate Control2–9 mL/min (adjustable in 0.5 mL/min increments)
Vacuum Control Accuracy±1% of setpoint
Condenser Temp Control30–90 °C (electric heating)
Cold Trap CoolingIntegrated compressor-based refrigeration
Detection MethodPhotoelectric detection for initial boiling point (IBP) and liquid level tracking
Heating SystemNi-Cr resistance heater (1 kW, 220 V AC) with forced-air cooling
Data InterfaceRS-232C serial port
Power Supply220 V AC, 50/60 Hz, 1500 W
Dimensions (W×D×H)700 × 750 × 580 mm
Weight~75 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-6536B
Standards ComplianceASTM D86, D850, D1078, D2892
Temperature Range10 °C to 400 °C (0.1 °C resolution)
Distillate Rate Control2–9 mL/min (adjustable in 0.5 mL increments, PID-regulated)
Condenser Temp Control0–80 °C (Peltier + resistive heating)
Receiver Bath Temp Control0/4 °C to ambient
DetectionPhotometric meniscus tracking (half-meniscus), CRC thermocouple dry-point sensor, Pt100 temperature sensing
Power SupplyAC 220 V, 50/60 Hz, 1500 W
Dimensions740 W × 650 D × 680 H mm
Weight~75 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-6536A
Standards ComplianceGB/T 6536, ASTM D86, ASTM D850, ASTM D1078, ASTM D2892, ISO 3405, IP 123, JIS K2254
Temperature Range10°C to 400°C (display resolution: 0.1°C)
Distillate Rate Control2–9 mL/min (adjustable in 0.5 mL/min increments)
Condenser Temperature Control0–80°C (Peltier + electric heating)
Receiver Bath Temperature Control0°C/4°C to ambient
Detection SystemsPhotometric meniscus tracking, CRC thermocouple dry-point sensor, Pt100 temperature sensor
Heating SourceNi-Cr tubular heater (220 V, 1 kW) with forced-air cooling
Control InterfaceFull-color LCD touchscreen with Windows-based GUI
Data OutputRS-232C serial port compliant with laboratory network integration
Calibration FunctionsAutomated multi-parameter correction (temperature, bath, ambient, pressure, volume, time)
Power SupplyAC 220 V, 50/60 Hz, 1500 W
Dimensions & Weight400 × 580 × 700 mm (W×D×H), ~40 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0