Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-9293
Testing MethodClosed-Cup & Open-Cup
Temperature Control Accuracy±0.1 °C
Operating Temperature RangesClosed-Cup (0–300 °C), Open-Cup (0–400 °C), Tag Closed-Cup (0–95 °C, optional Peltier cooling)
Detection MethodsFlame Ionization (Open-Cup), High-Sensitivity Thermocouple (Closed-Cup)
Compliance StandardsASTM D56, ASTM D92, ASTM D93, GB/T 261, GB/T 3536, GB/T 21929, SH/T 0733, GB/T 267
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-93S
Detection MethodClosed-Cup
Operation ModeFully Automatic
Temperature Range40 °C to 360 °C
Ignition ModesElectric Spark Ignition & External Fuel-Gas Ignition
RepeatabilityCompliant with ASTM D93 and GB/T 261 test protocols
Applicable StandardsGB/T 261–2008, ASTM D93
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXuFeng
OriginShanghai, China
ModelXF-5208
Detection MethodClosed-Cup Rapid Equilibrium Method
ComplianceGB/T 5208–2008, ISO 3679:2004
Temperature Range (XF-5208L)–5 °C to 110 °C
Temperature Range (XF-5208H)Ambient to 300 °C
Sample Volume (XF-5208L)2 mL per test
Sample Volume (XF-5208H)4 mL per test
Control Accuracy±0.5 °C
InterfaceRS-232C
Power Consumption800 W × 2
Dimensions280 mm (W) × 380 mm (D) × 350 mm (H)
Weight~15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-170
Detection MethodClosed-Cup (Abel)
Standards ComplianceISO 13736, ISO 1516, ISO 1523, IP 170, GB/T 21789-2008, GB/T 27847-2011, GB/T 27848-2011
Temperature Range (XF-170A)+10 °C to +110 °C
Temperature Range (XF-170B)0 °C to +110 °C
Extended Range (with DW-25 chiller)−30 °C to +80 °C
Cooling SystemIntegrated Peltier thermoelectric cooling bath
Stirring Speed0–30 rpm (adjustable)
Temperature SensorPT100 platinum resistance thermometer
Flash DetectionCRC-type thermocouple sensor
Ignition OptionsGas flame (external fuel supply) or electronic spark ignition
DisplayFull-color capacitive touchscreen LCD
Power Consumption800 W
Dimensions400 × 380 × 350 mm (W×D×H)
Weight~20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelFP92B
Test MethodCleveland Open Cup (COC), ASTM D92-compliant
Operation ModeFully Automatic
Temperature Range79–400 °C
Ignition MethodFully Automatic Gas Flame
Compliant StandardsGB/T 3536-2022, ISO 2592, ASTM D92, IP 36, JIS K 2265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXuFeng
OriginShanghai, China
ModelXF-92
Detection MethodOpen Cup (Cleveland)
Standards ComplianceASTM D92, GB/T 3536-2008, GB/T 267
Temperature Range0–400 °C
Control Accuracy±0.1 °C
Typical Test Range80–400 °C
Power Consumption2 × 800 W
Dimensions400 × 380 × 350 mm (W×D×H)
Weight~20 kg
DisplayFull-touch LCD screen
InterfaceRS-232C
OutputIntegrated dot-matrix printer
IgnitionAutomatic gas-fired or optional electronic igniter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-92SE
Detection MethodCleveland Open Cup (ASTM D92 / GB/T 3536)
Operation ModeFully Automatic
Temperature Range80 °C to 400 °C
Ignition MethodsElectric spark ignition (standard) and optional gas-fueled ignition
RepeatabilityCompliant with ASTM D92 and GB/T 3536 requirements
Applicable StandardsASTM D92, GB/T 3536
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXuFeng
OriginShanghai, China
ModelXF-93
Detection MethodClosed-Cup Method (Pensky-Martens)
Standards ComplianceASTM D93, GB/T 261–2008
Temperature Range0–360 °C (Typical Test Range: 40–360 °C)
Temperature Control Accuracy±0.1 °C
Power Consumption2 × 800 W
Dimensions (W×D×H)400 × 380 × 350 mm
Weight~20 kg
DisplayFull-touch LCD screen
InterfaceRS-232C
OutputIntegrated dot-matrix printer
IgnitionAutomatic gas-fired or optional electronic ignition head
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-56SE
Detection MethodClosed-Cup (Tag)
Operation ModeFully Automatic
Temperature RangeAmbient to 95 °C
Ignition MethodElectronic (Piezoelectric Spark)
RepeatabilityCompliant with ASTM D56, SH/T 0733, and GB/T 21929–2008 specifications
Applicable StandardsASTM D56, SH/T 0733, GB/T 21929–2008, ISO 1523, IP 304, JIS K 2265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelFP-C1A
Temperature Range0–400 °C (Typical Test Range: 80–400 °C)
Temperature SensorPt100 Platinum Resistance Thermometer
Atmospheric Pressure SensorSilicon-based Barometric Sensor
Flash DetectionElectrode-based Ionization Detector
Fire Point DetectionInfrared Sensor
DisplayLCD Panel
Heater Power800 W
Cooling MethodForced Air Cooling
Ignition SourceGas-fired (Propane/Butane)
InterfaceRS-232C Serial Port
Weight18 kg
Dimensions (Test Unit)215(W) × 410(D) × 260(H) mm
Dimensions (Control Unit)215(W) × 480(D) × 110(H) mm
Data Storage Capacity99 Test Records
ComplianceGB/T 3536–2008, ASTM D92–05a, ISO 2592
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-56SE
Detection MethodClosed-Cup (Tag)
Operation ModeFully Automatic
Temperature RangeAmbient to 95 °C (standard)
Ignition MethodsElectric spark ignition (standard on XF-56SE) and external fuel gas ignition (compatible via optional inlet)
RepeatabilityCompliant with ASTM D56, SH/T 0733, and GB/T 21929-2008
Applicable StandardsASTM D56, SH/T 0733, GB/T 21929-2008, ISO 1523, IP 304, JIS K 2265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-4S
Detection MethodCleveland Open-Cup (COC), Pensky-Martens Closed-Cup (PMCC), Tag Closed-Cup (TAG)
Temperature Control Range0–400 °C (Open-Cup), 0–300 °C (Closed-Cup), ±0.1 °C accuracy
Sample CapacityUp to 8 simultaneous cups (configurable per test standard)
ComplianceASTM D92, ASTM D93, ASTM D56, GB/T 261, GB/T 3536, GB/T 267
InterfaceRS-232C
Power2 × 800 W
Dimensions400 × 380 × 350 mm (W×D×H)
Weight~20 kg
Detection PrincipleFlame Ionization (open-cup), High-Sensitivity Thermocouple (closed-cup)
Data Storage100 test records per method configuration
DisplayLarge LCD with real-time temperature, setpoint, and fault diagnostics
PrinterBuilt-in dot-matrix
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-92S
Detection MethodOpen-Cup
Operation ModeFully Automatic
Temperature Range80 °C to 400 °C
Ignition ModesElectric Spark Ignition and External Fuel-Gas Ignition
RepeatabilityCompliant with ASTM D92 and GB/T 3536 test protocols
Applicable StandardsASTM D92, GB/T 3536
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-56
Detection MethodClosed-Cup (Tag)
Applicable StandardsASTM D56, SH/T 0733, GB/T 21929-2008, ISO 1523, IP 304, JIS K 2265
Temperature Control Range0 °C to 300 °C
Control Accuracy±0.1 °C
Standard Test RangeAmbient to 95 °C (water bath)
Cooling SourceImported Semiconductor Cold Trap
DisplayFull-Touch 7-inch LCD
Ignition DetectionAutomated Flame Ignition + High-Sensitivity Thermocouple
Power Consumption2 × 800 W
Dimensions400(W) × 380(D) × 350(H) mm
Weight~20 kg
InterfaceRS-232C
PrinterIntegrated Dot-Matrix Printer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelFP92
Detection MethodCleveland Open Cup (ASTM D92 / ISO 2592)
Operation ModeFully Automatic
Temperature Range80–400 °C
Ignition MethodFully Automatic Gas Flame
Compliant StandardsGB/T 3536-2022, ISO 2592:2021, ASTM D92-22, IP 36/07, JIS K 2265:2014
DisplayVFD Fluorescent Screen
Temperature SensorPt100 Platinum Resistance Thermometer
Flash DetectionIonization Ring (O-Ring Type)
Fire Point CapabilityYes (FIRE Mode with Integrated Extinguishing Function)
Pressure CompensationManual (ACOC) or Auto (ACOCH)
Data Storage50 Test Records
InterfaceRS-232C Serial Port
Power SupplyAC 230 V, 50 Hz, 1000 W
Dimensions231 × 456 × 386 mm (W × D × H)
Net Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelFP-P1A
Temperature Range0–360 °C (Operating: 40–360 °C)
Temperature SensorPt100 Platinum Resistance Thermometer
Pressure SensorSilicon-based Barometric Sensor
Ignition SourceGas-fired Pilot Flame
Detection MethodThermocouple-based Flash Detection
DisplayLCD Panel
Heater Power500 W
CoolingForced Air
InterfaceRS-232C Serial Port
Dimensions (Test Unit)215(W) × 410(D) × 270(H) mm
Dimensions (Control Unit)215(W) × 480(D) × 110(H) mm
Weight16 kg
ComplianceGB/T 261–2008, ASTM D93 (Methods A & B)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-93SE
Detection MethodClosed-Cup (Pensky-Martens)
Operation ModeFully Automatic
Temperature Range40 °C to 360 °C
Ignition MethodsElectric Spark Ignition (standard) and Optional Gas-Fueled Ignition
RepeatabilityCompliant with ASTM D93, GB/T 261, and JIS K 2265-3
Applicable StandardsGB/T 261–2008, ASTM D93–22, JIS K 2265-3
DisplayTouchscreen LCD (Chinese interface)
Power Consumption800 W
Dimensions (W×D×H)400 × 380 × 350 mm
Weight~20 kg
EnclosureDesktop, Stainless Steel Housing
Communication InterfaceRS-232C
Data OutputIntegrated Thermal Printer
Control ArchitectureMicroprocessor-Based with Self-Diagnostic Functionality
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXufeng
OriginShanghai, China
ModelXF-2S
Detection MethodClosed-Cup Method
Temperature Control Accuracy±0.1 °C
Operating Temperature Range (Closed Cup)0–300 °C
Operating Temperature Range (Open Cup)0–400 °C
ComplianceASTM D56, ASTM D92, ASTM D93, GB/T 261-2008, GB/T 3536-2008, GB/T 21929-2008, GB/T 267
DisplayLarge LCD Screen
Data OutputBuilt-in Dot-Matrix Printer
InterfaceRS-232C Serial Port
Power Consumption800 W × 2
Dimensions (W×D×H)400 × 380 × 350 mm
Weight~20 kg
Show next