- All
- Favorite
- Popular
- Most rated
| Brand | Yiheng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LRH Series |
| Price Range | USD 1,300 – 5,450 (FOB Shanghai) |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Air Circulation | Natural Convection |
| Temperature Range | 0–60 °C |
| Temperature Fluctuation | ±0.5 °C at High Temp |
| Temperature Uniformity | ±1.5 °C |
| External Dimensions (W×D×H, mm) | 530×560×1080 |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LRH-70F |
| Heating Method | Air-jacketed |
| Cooling Method | Compressor-based |
| Air Circulation | Natural Convection |
| Temperature Range | 0–60 °C |
| Temperature Fluctuation | ±0.5 °C (at high temp), ±1.0 °C (at low temp) |
| Temperature Uniformity | ±1.5 °C (measured at 25 °C) |
| Interior Dimensions (W×D×H) | 400 × 350 × 500 mm |
| External Dimensions (W×D×H) | 530 × 560 × 1080 mm |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | LRH-500F |
| Heating Method | Air-Jacketed |
| Cooling Method | Compressor-Based Refrigeration |
| Convection Type | Natural Convection |
| Temperature Range | 0–60 °C |
| Temperature Fluctuation | ±0.5 °C (at high setpoints), ±1.0 °C (at low setpoints) |
| Temperature Uniformity | ±2.5 °C (measured at 25 °C reference point) |
| Internal Dimensions (W×D×H) | 670×720×1020 mm |
| External Dimensions (W×D×H) | 850×1100×1930 mm |
| Brand | YIHENG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BPC Series |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Convection Type | Natural Convection |
| Temperature Range | −5 °C to 70 °C |
| Temperature Fluctuation | ±0.3 °C (High Temp), ±0.5 °C (Low Temp) |
| Temperature Uniformity | ±1.5 °C (at 25 °C test point) |
| Capacity | See Product Catalog |
| External Dimensions | See Product Catalog |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BPC-250F |
| Heating Method | Air-jacketed |
| Cooling Method | Compressor-based |
| Convection Mode | Natural Convection |
| Temperature Range | −5 °C to 70 °C |
| Temperature Fluctuation | ±0.3 °C (high-temp range), ±0.5 °C (low-temp range) |
| Temperature Uniformity | ±1.5 °C (at 25 °C test point) |
| Chamber Dimensions (W×D×H) | 520 mm × 550 mm × 1050 mm |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | LRH-250(F) |
| Heating Method | Air-jacketed |
| Cooling Method | Compressor-based |
| Convection Type | Natural convection |
| Temperature Range | 0–60 °C |
| Temperature Fluctuation | ±0.5 °C at high setpoints |
| Temperature Uniformity | ±1.5 °C (measured at 25 °C) |
| Interior Dimensions (W×D×H) | 503 × 370 × 808 mm |
| Exterior Dimensions (W×D×H) | 600 × 630 × 1360 mm |
| Brand | YiHeng |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LRH-Series |
| Price Range | USD 1,400–2,800 |
| Heating Method | Air-Jacketed |
| Temperature Range | 0–60 °C |
| Temperature Fluctuation | ±0.5 °C (at high setpoints), ±1.0 °C (at low setpoints) |
| Temperature Uniformity | ±1.5 °C (measured at 25 °C reference point) |
| Interior Dimensions (W×D×H) | 400 × 350 × 500 mm |
| External Dimensions (W×D×H) | 530 × 560 × 1080 mm |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BPC-150F |
| Heating Method | Air-jacketed |
| Cooling Method | Compressor-based |
| Air Circulation | Natural Convection |
| Temperature Range | −5 °C to 70 °C |
| Temperature Fluctuation | ±0.3 °C (high-temp range), ±0.5 °C (low-temp range) |
| Temperature Uniformity | ±1.5 °C (at 25 °C test point) |
| Capacity | Refer to manufacturer’s catalog |
| External Dimensions | Refer to manufacturer’s catalog |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BPC-70F |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Air Circulation | Natural Convection |
| Temperature Range | −5 °C to 70 °C |
| Temperature Fluctuation | ±0.3 °C (High-Temp Mode), ±0.5 °C (Low-Temp Mode) |
| Temperature Uniformity | ±1.5 °C (at 25 °C test point) |
| Interior Dimensions (W×D×H) | 400 mm × 440 mm × 500 mm |
| Brand | YiHeng |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LHR-500F |
| Heating Method | Air-jacketed |
| Temperature Range | 0–60 °C |
| Temperature Fluctuation | ±0.5 °C (at high temp), ±1.0 °C (at low temp) |
| Temperature Uniformity | ±2.5 °C (measured at 25 °C) |
| Internal Dimensions (W×D×H) | 670×720×1020 mm |
| External Dimensions (W×D×H) | 850×1100×1930 mm |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LRH |
| Price Range | USD 2,150 – 8,800 (FOB Shanghai) |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Temperature Range | LRH-L: −10 °C to +65 °C |
| LRH-A | −20 °C to +65 °C |
| LRH-B | −40 °C to +65 °C |
| Temperature Uniformity | ±0.5 °C (at ≥25 °C), ±1.0 °C (at ≤0 °C) |
| Internal Volume Options | 150 L, 250 L, 400 L, 600 L (per catalog) |
| External Dimensions | Varies by capacity (see technical datasheet) |
| Brand | YiHeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Numbers | LRH-800F, LRH-1000F, LRH-1500F |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Heating Method | Air-Jacketed Heating |
| Cooling Method | Compressor-Based Refrigeration |
| Temperature Range | Standard Mode (F): 0–60°C |
| Low-Temp Mode (L) | −10–60°C |
| Temperature Fluctuation | ±0.5°C (at high setpoints), ±1.0°C (at low setpoints) |
| Temperature Uniformity | ±2.5°C (measured at 25°C reference point) |
| Internal Dimensions (W×D×H) | 730 × 750 × 1480 mm |
| External Dimensions (W×D×H) | 870 × 1085 × 2065 mm |
| Brand | YIHENG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Method | Air-Jacketed |
| Cooling Method | Compressor-Based Refrigeration |
| Convection Mode | Natural Convection |
| Temperature Range | −10 °C to +65 °C |
| Temperature Uniformity | ±0.5 °C (at ≥25 °C), ±1.0 °C (at ≤0 °C) |
| Interior Dimensions (W×D×H) | 500 mm × 400 mm × 600 mm |
| External Dimensions (W×D×H) | 650 mm × 770 mm × 1320 mm |
| Optional Features | RS485 Interface, Thermal Printer Output, Multi-Stage Programmable Controller (up to 30 segments, 1–5999 min/segment) |
| Brand | Yiheng |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Heating Method | Air-jacketed |
| Cooling Method | Compressor-based |
| Temperature Range | −5 to 70 °C |
| Temperature Fluctuation | ±0.3 °C (high-temp), ±0.5 °C (low-temp) |
| Temperature Uniformity | ±1.5 °C |
| Chamber Dimensions (W×D×H, mm) | 500×460×800 |