Empowering Scientific Discovery

Shanghai Yilin Instrument Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelpHDTM Differential
PriceUpon Request
Measurement RangepH 0–14, ORP −1500 to +1500 mV
Accuracy±0.01 pH, ±0.5 mV
Temperature Range−5 to 95 °C
Max Pressure6.9 bar at 105 °C
Sensor Body MaterialsPEEK or Ryton
Replaceable Salt BridgeYes
Optional Auto-Cleaning AssemblyAvailable
Patented TechnologyUS Patent No. 6,398,181 B1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelGLI 3/4-inch
Body MaterialRyton® (general-purpose) / PVDF (insertion-type) / PVDF with 316SS liner (sanitary-type)
pH Range0–14
ORP Range−2000 to +2000 mV
Temp. Range0–105 °C
Max. Pressure6.9 bar at 100 °C
Flow Rate Limit≤2 m/s (non-abrasive fluids)
pH Accuracy<0.1 pH
ORP Accuracy±20 mV (in standard solutions)
Temperature CompensationBuilt-in Pt1000
Reference SystemDual-salt-bridge
GroundingIntegrated ground connection
Thread3/4″ NPT (general-purpose)
Flange2″ sanitary clamp (sanitary-type)
Cable Length4.5 m (standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelSC1000
Operating Temperature-20 to 55 °C
Storage Temperature-20 to 70 °C
Relative Humidity0–95% RH (non-condensing)
Power Supply100–230 VAC, 50/60 Hz
Display1/4 VGA backlit TFT color touchscreen
Relay Outputs4 × SPDT
Analog Outputs4–20 mA (up to 12 channels, 500 Ω max load)
Analog Inputs12 × 4–20 mA (500 Ω max input impedance)
Digital CommunicationMODBUS RTU (RS485 & RS232), PROFIBUS DP, Ethernet service port, optional GSM cellular module
Sensor ConnectivityUp to 8 digital sensors per probe module
Enclosure RatingIP65 (panel-mounted display module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelSC200
Input TypesDual digital (Hach Digital Sensor Protocol) and/or analog (4–20 mA, 0–20 mA, mV) sensor inputs
Communication ProtocolsMODBUS RTU (RS232/RS485), Profibus DPV1 (optional)
Display240 × 160 pixel graphical LCD with LED backlight
Enclosure RatingNEMA 4X / IP66
Power Supply100–240 VAC ±10%, 50/60 Hz or 24 VDC (−15% / +20%)
Operating Temperature−20 to 60 °C
Housing MaterialPolycarbonate front, powder-coated aluminum and stainless steel chassis
Mounting OptionsWall, pole, or panel mount
Output SignalsTwo independent 4–20 mA outputs (max. 500 Ω load)
Relay OutputsFour SPDT relays (5 A, 250 VAC, 1200 W)
Data StorageFlash memory with password-protected SD card slot
CertificationsCE (EMC: EN 50081-2, immunity: EN 61000-6-2), UL 61010-1, ETL Listed
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0