BrandHach
OriginUSA
Model2100Q
Measurement Range0–1000 NTU
Accuracy±2% of reading + stray light contribution
Stray Light< 0.02 NTU (FNU)
Resolution0.01 NTU at lowest range
Calibration OptionsSingle-point RapidCal (0–40 NTU), Full-range (0–1000 NTU), and Turbidity-to-TSS correlation (0–100 mg/L)
Data StorageUp to 500 measurements with timestamp, operator ID, sample ID, calibration status, and error logs
Compliance2100Q complies with USEPA Method 180.1
Signal AveragingUser-selectable On/Off
Measurement ModesNormal, Signal-Averaged, Rapid-Settling Turbidity (RST)
Display GuidanceOn-screen calibration & verification prompts
Data TransferUSB + power module (no additional software required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
Model2100N
PriceUpon Request
Range0–4000 NTU
Accuracy±2% of reading (0–1000 NTU), ±5% of reading (1000–4000 NTU)
Resolution0.001 NTU
Minimum Sample Volume20 mL
Measurement ModesNTU, NEP, EBC
Ratio MeasurementYes
Signal AveragingProgrammable
Sample Chamber PurgeCompressed air compatible
Operating Environment10–40 °C, ≤90% RH (non-condensing at 25 °C)
Power Supply230 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Model1900C
Measurement PrincipleNephelometric (90° light scattering) per USEPA Method 180.1
Range0–1000 NTU (auto-ranging)
or manual ranges0–9.99 / 0–99.9 / 0–1000 NTU
Resolution0.01 NTU (at lowest range)
Accuracy±1% linearity error
Repeatability≤1% (0–1000 NTU)
Zero Drift±1.5% F.S.
Stability±1.5% F.S.
Power4 × AA alkaline batteries or optional AC adapter
Operating Temperature0–50 °C
Weight520 g
ComplianceFully compliant with USEPA Method 180.1
Optical SystemDual-detector ratiometric optical design with signal averaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Model2100AN
Measurement PrincipleNephelometric (90° light scattering) with dual-detector ratio mode
Turbidity Range0–10,000 NTU
Color Range0–500 CU
Accuracy±2% of reading (0–1000 NTU), ±5% (1000–4000 NTU), ±10% (4000–10,000 NTU)
Resolution0.001 NTU / 1 CU
Repeatability±1% of reading or 0.01 NTU
Minimum Sample Volume20 mL
ComplianceEPA Method 180.1
Operating Environment10–40 °C, ≤90% RH (non-condensing at 25 °C)
Power Supply230 V, 50/60 Hz
Weight3.43 kg
Data OutputBuilt-in thermal printer, USB interface for HachLink™ software
Sample Chamber PurgeCompressed air port for dew prevention