Empowering Scientific Discovery

Shanghai Yilin Instrument Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ModelHI98309
Measurement Range0.000 to 1.999 µS/cm
Resolution0.001 µS/cm
Accuracy±2% of Full Scale
CalibrationFactory-Calibrated (No User Calibration Required)
Power Supply4 × 1.5 V Button Cell Batteries (LR44)
Operating Environment0 to 50 °C
Dimensions175 × 41 × 23 mm
Weight95 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ModelHI98303, HI98304
Measurement Range0–1999 µS/cm (HI98303), 0.00–19.99 mS/cm (HI98304)
Resolution1 µS/cm (HI98303), 0.01 mS/cm (HI98304)
Accuracy±2% F.S.
CalibrationManual single-point
Recommended Calibration SolutionsHI7031L (for HI98303), HI7030L (for HI98304)
Temperature CompensationAutomatic (0–50°C)
Power Supply4 × 1.5 V AAA batteries
Operating Environment0–50°C, ≤95% RH
Dimensions & Weight175 × 41 × 23 mm, 95 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOHAUS
OriginUSA
ModelStarter 300
pH Range0.00–14.00
mV Range−1999 to +1999 mV
Temperature Range0.0–100.0 °C
Resolution0.01 pH / 1 mV / 0.1 °C
Accuracy±0.01 pH / ±1 mV / ±0.5 °C
CalibrationUp to 3-point with user-defined buffer sets
Temperature CompensationAutomatic or manual (NTC 3 kΩ)
Input Impedance>5 × 10¹² Ω
IP RatingIP54
DisplayBacklit LCD
Power9 V DC adapter (AC 220 V/50 Hz input)
Dimensions160 × 200 × 65 mm
Weight0.65 kg
Housing MaterialABS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOHAUS
OriginUSA
ModelMB25
Capacity110 g / 99 g (moisture mode)
Readability0.01 g / 0.005 g
Moisture Readability (>10 g sample)0.05%
Repeatability (3 g sample)0.2%
Repeatability (10 g sample)0.05%
Minimum Sample Mass0.5 g
Recommended Sample Mass3–20 g
Pan DiameterØ90 mm
Heating SourceHalogen lamp
Temperature Range50–160 °C (in 5 °C increments)
Heating Time1–60 min (30 s increments), 60–90 min (1 min increments)
End Point ModesTimed, Automatic
DisplayBacklit LCD showing moisture %, solids %, weight, time, temperature
InterfaceBidirectional RS232
Operating Environment10–30 °C
Dimensions (W×H×D)165 × 127 × 280 mm
Net Weight2.1 kg
Gross Weight4.2 kg
Sample Pan HandleStandard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMYRONL
OriginUSA
ModelUltrameter 4P
PortabilityPortable
Conductivity Range0–200 mS/cm
TDS Range0–9999 ppm
Resistivity Range10 kΩ·cm – 30 MΩ·cm
Salinity RangeNot applicable (dedicated conductivity/TDS/resistivity/temperature model)
Temperature Range0–71 °C
Accuracy±1% of reading
Minimum Conductivity Resolution0.01 µS/cm
Enclosure RatingIP67 (NEMA 6)
Data Storage20 points with timestamp
Auto-Temperature CompensationYes (0–71 °C)
Electrode DesignIntegrated, field-replaceable dual-cell conductivity sensor with built-in temperature probe
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOHAUS
OriginUSA
ModelMB23
Capacity110 g
Readability0.01 g
Moisture Readability (≥10 g sample)0.1%
Repeatability (3 g sample)0.3%
Repeatability (10 g sample)0.2%
Minimum Sample Mass0.5 g
Recommended Sample Mass3–20 g
Pan DiameterØ90 mm
Heating Temperature Range50–160 °C (in 5 °C increments)
Heating Time1–60 min (30 s increments), 60–90 min (1 min increments)
Endpoint DetectionTimed or Automatic
DisplayMoisture %, Solid %, Weight, Time, Temperature
InterfaceBidirectional RS232
Operating Ambient Temperature10–30 °C
Dimensions (W×H×D)165 × 127 × 280 mm
Net Weight2.1 kg
Gross Weight4.15 kg
Heating SourceInfrared Halogen Lamp
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
Instrument TypeBenchtop
ModelFE20
pH Range0.00–14.00
pH Resolution0.01
Relative pH Accuracy±0.01
mV/ORP Range−1999 to +1999 mV
mV Resolution1 mV
Relative mV Accuracy±1 mV
Temperature Range0.0–100.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
CalibrationUp to 3-point, with 4 pre-defined buffer sets
DisplayLCD
Power SupplyExternal AC adapter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ModelHI98129 / HI98130
pH Range0.00–14.00 pH
EC Range0–3999 µS/cm (HI98129) / 0.00–20.00 mS/cm (HI98130)
TDS Range0–2000 ppm (HI98129) / 0.00–10.00 ppt (HI98130)
Temperature Range0.0–60.0°C
pH Resolution0.01 pH
EC Resolution1 µS/cm (HI98129) / 0.01 mS/cm (HI98130)
TDS Resolution1 ppm (HI98129) / 0.01 ppt (HI98130)
Temp Resolution0.1°C / 0.1°F
pH Accuracy±0.05 pH
EC/TDS Accuracy±2% F.S.
Temp Accuracy±0.5°C
CalibrationAuto 1-/2-point pH
ATC0.0–60.0°C
Power4 × 1.5 V AAA batteries
IP RatingIP67
Dimensions163 × 40 × 26 mm
Weight100 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ModelHI98127 / HI98128
pH Range-2.0 to 16.0 pH (HI98127), -2.00 to 16.00 pH (HI98128)
Temperature Range-5.0 to 60.0°C / 23.0 to 140.0°F
pH Resolution0.1 pH (HI98127), 0.01 pH (HI98128)
Temperature Resolution0.1°C / 0.1°F
pH Accuracy±0.1 pH (HI98127), ±0.05 pH (HI98128)
Temperature Accuracy±0.5°C / ±1°F
CalibrationAutomatic 1- or 2-point with memory for two calibration sets (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18)
Temperature CompensationAutomatic (ATC)
Power4 × 1.5 V AAA batteries
Operating Environment-5 to 50°C, up to 100% RH
Dimensions & Weight163 × 40 × 26 mm, 100 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelHG63
Temperature Range40–200 °C
Weight Readability1 mg
Moisture Content Readability0.01 %
Minimum Sample Weight0.1 g
Maximum Sample Weight61 g
Repeatability (2 g sample)±0.05 %
Repeatability (10 g sample)±0.01 %
Drying ProgramsStandard & Rapid
Shut-off Criteria5-level automatic, manual, time-controlled
Stored MethodsUp to 10
InterfaceLocalCAN / optional RS232
DisplayBacklit LCD
Dimensions (W×D×H)360 × 340 × 110 mm
Net Weight7.7 kg (with built-in printer)
LanguagesEnglish, French, German, Italian, Russian, Spanish
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOHAUS
OriginUSA
ModelSTARTER 2100/3C Pro
pH Range0.00–14.00
mV Range−1999 to +1999 mV
Temperature Range0.0–100.0 °C
Resolution0.01 pH / 1 mV / 0.1 °C
Accuracy±0.01 pH / ±1 mV / ±0.5 °C
CalibrationUp to 3-point with auto-buffer recognition
Temperature CompensationAutomatic or manual (NTC 30 kΩ sensor)
Input Impedance>10¹² Ω (BNC pH input)
PowerAC 110–240 V, 50 Hz / DC 12 V
Dimensions220 × 175 × 78 mm
Weight0.75 kg
DisplayLCD
Housing MaterialABS
ComplianceCE, ISO 9001, CMC certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelSG3
Conductivity Range0.10 µS/cm to 500 mS/cm
Temperature Range–5.0 to 105.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.2 °C
Conductivity Accuracy±0.5%
Salt Range0.00–80.00 ppt
TDS Range0.10 mg/L–300 g/L
TDS Resolution0.01–1 (unit-dependent)
TDS Accuracy±0.5%
DisplayCustom LCD
Power4 × AA alkaline or rechargeable batteries
Operating Environment5–40 °C, 5–80% RH (non-condensing)
Data Storage30 measurements
IP RatingIP67 (with InLab® 738/742 electrodes)
ComplianceMeets ISO 7888, ASTM D1125, USP <645>, and GLP data integrity requirements for field and lab use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ModelHI98301 / HI98302
Measurement Range (HI98301)0–1999 ppm (mg/L)
Resolution (HI98301)1 ppm
Measurement Range (HI98302)0.00–10.00 ppt (g/L)
Resolution (HI98302)0.01 ppt
Accuracy±2% of full scale
CalibrationManual single-point with HI7032L (for HI98301) or HI70038P (for HI98302)
Temperature CompensationAutomatic, 0–50 °C
Power4 × 1.5 V AAA batteries
Dimensions175 × 41 × 23 mm
Weight95 g
Operating Environment0–50 °C, ≤95% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMyronL
OriginUSA
ModelEP/512M5/EP10
Conductivity Ranges0–0.5 µS, 0–5 µS, 0–50 µS, 0–500 µS, 0–5000 µS, 0–10 mS, 0–100 mS, 0–1000 mS, 0–10,000 µS
Resistivity Range2–30 MΩ
Accuracy±2% of full scale (all ranges)
Automatic Temperature Compensation10–71 °C
Power9 V alkaline battery (≈2000 measurements/year)
Electrode TypeMaintenance-free conductive cell
ComplianceDesigned for field and lab use in accordance with ASTM D1125 and ISO 7888 principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelS20
pH Range0.00–14.00
pH Resolution0.01
Relative pH Accuracy±0.01
mV Range−1999 to +1999 mV
mV Resolution1 mV
Relative mV Accuracy±0.4
Temperature Range−5.0 to 105.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
DisplayLCD
Power SupplyExternal AC adapter or 4× AA (LR6) batteries
CalibrationAuto-buffer recognition, user-definable buffer sets, ATC, auto-endpoint hold
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMYRON L
OriginUSA
ModelUltrameter 6P
Instrument TypePortable
Parameter Count6
Measurement Accuracy±0.01 pH
pH Range0–14
pH Resolution0.01
pH Accuracy±0.01 pH
Calibration SolutionpH 7 buffer
Conductivity RangeAuto-ranging 0–9999 µS/cm, 10–200 mS/cm
TDS Range0–9999 ppm, 10–200 ppt
Resistivity Range10 kΩ·cm – 30 MΩ·cm
ORP Range±999 mV
Temperature Range0–71 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.1 °C
Auto Temperature CompensationYes (0–71 °C)
IP RatingIP67 (NEMA 6)
Data Storage20 points with timestamp
EnclosureFully sealed, buoyant, submersible to 1 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelFG2
Instrument TypePortable
pH Range0.00–14.00
pH Resolution0.01
pH Accuracy (relative)±0.01
mV Range−1999 to +1999 mV
mV Resolution1 mV
mV Accuracy (relative)±1
Temperature Range0.0–100.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
CalibrationUp to 3-point, with 4 predefined buffer sets
Data Storage30 measurements
DisplayLCD
Power Supply4 × AAA 1.5 V batteries
IP RatingIP54
Operating Environment0–40 °C, 5–80 % RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMYRONL
OriginUSA
Model532T1
Measurement PrincipleTwo-electrode conductivity cell with linear TDS conversion (NaCl equivalence)
TDS Range0–50 / 0–500 / 0–5000 ppm (auto-ranging)
Resolution1 ppm (0–50 ppm), 10 ppm (0–500 ppm), 100 ppm (0–5000 ppm)
Accuracy±2% of full scale
Temperature CompensationAutomatic, 10–71 °C
pH Range0.0–14.0 (with replaceable pH electrode)
Power9 V alkaline battery (approx. 2,000 measurements/year)
Electrode TypeMaintenance-free graphite conductivity cell
EnclosureIP65-rated rugged ABS housing
ComplianceDesigned for field and lab use per ASTM D1125 and ISO 7888 guidelines for conductivity/TDS estimation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ModelHI98107
pH Range0.0 to 14.0
Resolution0.1 pH
Accuracy±0.1 pH
CalibrationManual 2-point
ElectrodeHI73106 replaceable pH electrode
Power4 × 1.5 V AAA batteries
Operating Environment0 to 50 °C, ≤95% RH
Dimensions175 × 41 × 23 mm
Weight95 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelMJ33
Temperature Range50–160 °C
Min. Sample Weight0.5 g
Max. Sample Weight35 g
Repeatability (2 g)±0.15 %
Repeatability (10 g)±0.05 %
Readability (Moisture)0.01 %
Readability (Weight)1 mg
Drying Programs1 (Standard)
Switch-off CriteriaAutomatic, Manual, Time-controlled
DisplayBacklit LCD
InterfaceRS232C
LanguagesEnglish, French, German, Italian, Spanish, Portuguese, Japanese, Russian
Dimensions (W×D×H)230 × 360 × 150 mm
Weight4.3 kg
PrinterExternal (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelSG2
pH Range0.00–14.00
pH Resolution0.01
pH Accuracy (relative)±0.01
mV Range−1999 to +1999 mV
mV Resolution1 mV
mV Accuracy (relative)±1
Temperature Range−5.0 to 105.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
DisplayCustom LCD
IP RatingIP67
Data Storage30 measurements
CalibrationUp to 3-point, with predefined or user-defined buffer sets (DIN, NIST, US, TECH)
ConnectivityIR interface (RS232/USB via optional adapter)
Operating Environment5–40 °C, 5–80% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelS30
Temperature Range–5.0 to 105.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.2 °C
Conductivity Range0.01 µS/cm to 500 mS/cm (auto-ranging)
Conductivity Accuracy±0.5% of reading
Salinity Range0.00–80.00 ppt
TDS Range0.1 mg/L to 500 g/L
TDS FactorUser-definable (0.40–1.00)
Resistivity Range0.000 Ω·cm to 100.0 MΩ·cm
Electrode Constant InputUser-configurable
DisplayBacklit LCD with simultaneous parameter + temperature readout
Power SupplyAC adapter (included) or 4× AA (LR6) batteries
InterfaceRS232 for data export
ComplianceDesigned for GLP-compliant workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelFG3
Conductivity Range0.01 µS/cm to 199.9 mS/cm
TDS Range0.01 mg/L to 199.9 g/L
Salinity Range0.00–19.99 psu
Temperature Range0.0–100.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.3 °C
Conductivity Accuracy±0.5 % of reading
CalibrationSingle-point automatic calibration
DisplayLCD with simultaneous readout of conductivity/TDS/salinity, temperature, endpoint status, and system symbols
Protection RatingIP54
Power Supply4 × AAA 1.5 V batteries
Operating Environment0–40 °C, 5–80 % RH
Data Storage30 measurement records
CompensationLinear temperature compensation with selectable reference temperature (e.g., 20 °C or 25 °C)
Auto-Endpoint DetectionYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelFE30
Temperature Range0.0–100.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.3 °C
Conductivity Range0.00 µS/cm to 199.9 mS/cm
TDS Range0.00 mg/L to 199.9 g/L
Conductivity Accuracy±0.5% of reading
DisplayLCD
Power SupplyExternal AC adapter
Operating Environment5–40 °C, 5–80% RH
ComplianceDesigned for GLP-compliant workflows
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0