Empowering Scientific Discovery

Shanghai Yilin Instrument Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTES
OriginTaiwan
ModelTES-1350A
Measurement Range (A-weighted, LO)35–100 dB
Measurement Range (A-weighted, HI)65–130 dB
Measurement Range (C-weighted, LO)35–100 dB
Measurement Range (C-weighted, HI)65–130 dB
Frequency Range31.5 Hz – 8 kHz
Accuracy±2 dB
Resolution0.1 dB
Dynamic Range65 dB
Weighting NetworksA and C
Time WeightingFast & Slow
Max Hold FunctionYes
Microphone TypePolarized Condenser
CalibrationInternal 94.0 dB Reference
AC Output~0.65 Vrms per range, 600 Ω impedance
DC Output~10 mV/dB (nominal), 100 Ω impedance
Operating Temperature0–40 °C, <80% RH
Storage Temperature−10–60 °C, <70% RH
Display3½-digit LCD
Power Supply1 × 9 V battery
Dimensions240 × 68 × 25 mm
Weight215 g
AccessoriesCarrying case, test rod, 9 V battery, instruction manual, windscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck Millipore
OriginGermany
Product TypeMulti-ion Colorimetric Test Strips
Parameter RangeH₂O₂/Peroxides, Total Hardness, pH, and 30+ Additional Analytes
ComplianceDesigned for ISO/IEC 17025-aligned field testing and routine QC screening
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelDR890
Wavelength Range420, 520, 560, 610 nm
Wavelength Accuracy±1 nm
Photometric Range0–2 A
Measurement Modes% Transmittance, Absorbance, Concentration
Data Storage Capacity99 samples
Power Supply4 × AA alkaline batteries
Weight470 g
Operating Environment0–50 °C, ≤90% RH (non-condensing)
ConnectivityIR interface (with optional RS232 adapter)
ComplianceDesigned for field-deployable compliance with ASTM D1293, D3370, D511, D3223, USP <643>, ISO 7027, ISO 8467, and EPA-approved colorimetric methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck
OriginGermany
ModelPicco COD
Instrument TypePortable
Wavelength610 ± 20 nm
Measurement Range0–10000 mg/L (multi-range, segmented)
Accuracy≤ ±10%
Repeatability≤ ±5%
LOD0.1 mg/L
Measurement Time< 5 seconds (post-digestion)
Batch Capacity12 or 24 samples (digestion-dependent)
Power Supply9-V alkaline battery (≈600 measurements)
Operating Temperature5–40 °C
Relative Humidity30–90% RH (non-condensing)
ComplianceCE marked per DIN EN 55022, EN 61000-4-2, EN 61000-4-8, EN 50082-2, EN 50081-1, DIN V ENV 50140, EN 50204
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNew Cosmos
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelCV-819
Instrument TypeOnline Monitoring System
Detection PrincipleHybrid Sensor Array (Metal Oxide Semiconductor – MOS, Electrochemical – EC, and Photoionization Detector – PID)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMillipore
OriginGermany
ModelCement Waste Heat Power Generation Water Quality Test Kit
Measurement PrincipleVisual Colorimetric Analysis (Standardized Reagent-Based Method)
Test ParametersPhosphate (3–120 ppm), Chloride (2 mg/L detection limit
Test Frequency190–300 determinations per reagent vial
ComplianceDesigned for routine industrial water monitoring in accordance with ISO 9001-supported QA/QC workflows and aligned with ASTM D511 (chloride), ASTM D5845 (phosphate), and ISO 6059 (hardness) test method principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTES
OriginTaiwan
ModelAVM-305
Wind Speed Range0.0–45.0 m/s (0.0–100.0 mph, 0.0–88.0 knots, 0.0–160.0 km/h, 0.0–8800 ft/min)
Resolution0.01 m/s (selectable units)
Accuracy±3% ±0.2 m/s (threshold: 0.3 m/s)
Air Temperature Range–5.0–60.0 °C / 32.0–140.0 °F
Temp Accuracy±1.0 °C / ±1.8 °F
Display4-digit LCD
Power2 × 1.5 V AA batteries (6 mA typical, ~200 h life)
Operating Temp0–50 °C (instrument), 0–60 °C (vane probe)
Humidity<80% RH
Pressure Range500 mbar–2 bar
Dimensions (meter)78 × 130 × 40 mm
Dimensions (vane)66 × 132 × 29.2 mm
Weight250 g (with batteries)
Mounting1/4″–20 threaded port
ComplianceCE-marked, RoHS-compliant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelTSS Portable
Instrument TypePortable
Measurement PrincipleMulti-beam alternating infrared photometry with dual-channel 90° scattering (turbidity) and six-channel multi-angle absorbance-corrected detection (suspended solids)
Turbidity Range0.001–4000 NTU
Suspended Solids Range0.001–400 g/L (1–400,000 mg/L, upper limit sample-dependent)
Turbidity Accuracy±3% or ±0.02 NTU (whichever is greater)
SS Accuracy±4% or ±0.001 g/L (whichever is greater)
Turbidity Resolution0.001 NTU (0–0.999), 0.01 NTU (1–9.99), 0.1 NTU (10–99.9), 1 NTU (>100)
SS Resolution0.001 g/L (0–0.999), 0.01 g/L (1–9.99), 0.1 g/L (10–99.9), 1 g/L (>100)
UnitsNTU, FNU, EBC (turbidity)
Calibration4 pre-stored SS calibration curves + 1 turbidity curve
Bubble CompensationReal-time software-based bubble interference correction
Sensor MaterialElectropolished 316 stainless steel housing with scratch-resistant sapphire window
Data Storage290 measurement records (timestamp, location, value, homogeneity flag)
Operating ModesSingle-point, Interval, Continuous
BatteryRechargeable Li-ion
DisplayBacklit graphical LCD with intuitive menu navigation
ComplianceMeets DIN EN ISO 7027 (turbidity), supports ASTM D3852, ISO 13319, and USP <730> for suspended solids quantification in water matrices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelSG6
Temperature Range0.0–60.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.1 °C
Dissolved Oxygen Range0.0–600 % saturation / 0.00–99.00 mg/L
DO Resolution0.1–1 % / 0.01 mg/L
DO Accuracy±0.5 %
Atmospheric Pressure Range500–1100 mbar
IP RatingIP67
Data Storage200 GLP-compliant records
DisplayBacklit custom LCD
Power Supply4 × AA alkaline or rechargeable batteries
Operating Environment5–40 °C, 5–80 % RH (non-condensing)
InterfaceInfrared (IR) for data transfer to printer or PC (RS232/USB via optional adapter)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck Millipore
OriginGermany
Product TypePre-calibrated Colorimetric Test Kits (AquaQuant®, MicroQuant®, Aquamerck®)
Parameter RangeTotal Hardness, Free Chlorine, Alkalinity, Phosphate, Ammonia-N, Nitrate, Nitrite, Iron, Copper, Calcium, Magnesium, Dissolved Oxygen, Silica, Sulfate, Cyanide, Ozone, Chlorine Dioxide, and 30+ additional parameters
ComplianceISO 9001-certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelFG4
Measurement PrincipleGalvanic Cell (Zero-Polarization)
Temperature Range0.0–50.0 °C
Temp. Resolution0.1 °C
Temp. Accuracy±0.3 °C
DO Range (%)0.00–199.9% (extended to 400%)
DO Range (mg/L & ppm)0.0–45.0 mg/L (ppm)
DO Resolution0.1% / 0.01 mg/L / 0.01 ppm
DO Accuracy±1% of reading or ±1 mg/L (whichever is greater)
Salt Range0.0–50.0 ppt (0.1 ppt resolution)
Atmospheric Pressure Range375–825 mmHg / 500–1100 mbar / 500–1100 hPa
Pressure Resolution1 unit
Calibration Points2-point (0% and 100% O₂)
Data Storage30 measurements
DisplayBacklit LCD with simultaneous readout of DO value, temperature, endpoint status, and compensation indicators
Enclosure RatingIP54
Power Supply4 × 1.5 V AAA batteries
Operating Environment0–40 °C, 5–80% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMillipore
OriginGermany
ModelPharo 100
Wavelength Range320–1100 nm
Light SourceTungsten Halogen Lamp
Optical SystemStabilized Single-Beam
Spectral Bandwidth4 nm
Wavelength Resolution1 nm
Wavelength Accuracy±1 nm
Absorbance Range±3.3 A
Absorbance Resolution0.001 A
Absorbance Accuracy±0.003 A (A < 0.600)
Cuvette Compatibility16 mm round, 10/20/50 mm square (auto-recognized)
Scan Increment1 nm
Data Storage1000 measurement results + 4 MB for spectral/dynamic data
Interfaces1× USB-A, 1× USB-B, 1× RS-232
IP RatingIP31
Operating Temperature+10 °C to +35 °C
Dimensions404 × 197 × 314 mm (L×H×W)
Weight~3.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDUSTMATE
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelOxiTop IS6 / OxiTop IS12
Measurement PrincipleMercury-Free Pressure-Based Respirometry
BOD Range0–4000 mg/L (extendable to 5000 mg/L)
Measurement DurationUp to 7 days (automated daily readings)
ComplianceDIN 38409-52, CE, TÜV/GS, UL, cUL
Power Supply2 AA batteries (typical service life: 12 months)
Temperature CompensationAutoTemp™ integrated sensor-based compensation
Data Storage5 sequential daily BOD values (BOD₁ to BOD₅ or BOD₇)
Display2-digit LED (00–50
User InterfaceDual-button operation (M = measured value, S = stored value)
Sensor TypePiezoresistive pressure transducer
StirringAutomatic constant-speed magnetic stirring
CertificationCompliant with ISO 5815-1:2019 for BOD determination in water
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelHQ30d with LDO Sensor
Measurement Range0–20 mg/L (ppm) and 0–200% saturation
Resolution0.01 mg/L
Sensor TypeOptical (Luminescence-based)
Cable Options1 m, 3 m, 5 m, 10 m, 15 m, 30 m (standard & rugged variants)
ComplianceDesigned for ASTM D888, ISO 5814, and EPA Method 4500-O G
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEURO TECH
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelET1200
PricingUpon Request
Measurement Range0–1000 mg/L
Detection Limit0.2 mg/L (in CCl₄ extract)
RepeatabilityRSD < 3%
Wavenumber Range3400–2400 cm⁻¹
Wavenumber Accuracy±2 cm⁻¹
Output ModesConcentration, Absorbance, Transmittance
InterfaceRS232
Power Supply220 V ±10%, 50 Hz
Dimensions500 × 380 × 220 mm
Weight15 kg
Operating Temperature5–35 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck
OriginGermany
ModelNOVA60 / NOVA60A
Instrument TypeBenchtop & Field-Portable Photometric Water Analyzer
Wavelength Range12 fixed wavelengths (340, 410, 445, 500, 525, 550, 565, 605, 620, 665, 690, 820 nm)
Wavelength Accuracy±2 nm
Spectral Bandwidth10 nm
Absorbance Repeatability±0.001 A at 1.000 A
Absorbance Range–0.300 to 3.200 A
Cell Compatibility10/20/50 mm square cuvettes and 16 mm round cells with automatic recognition
Barcode Method RecognitionYes
Light SourceTungsten halogen lamp (no warm-up required)
Measurement Time~2 seconds per test
Data StorageUp to 1,000 results
User-Defined MethodsUp to 50 calibration curves
Power Supply220 V, 50 Hz (NOVA60)
Operating Temperature+5 °C to +40 °C
Storage Temperature–25 °C to +65 °C
Dimensions (H × D × W)140 × 270 × 260 mm
Weight2.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMillipore
OriginGermany
ModelPharo 300
Wavelength Range190–1100 nm
Light SourceXenon flashlamp
Optical SystemStabilized single-beam
Spectral Bandwidth4 nm
Wavelength Resolution1 nm
Wavelength Accuracy±1 nm
Absorbance Range±3.3 A
Absorbance Resolution0.001 A
Absorbance Accuracy±0.003 A (A < 0.600 A)
Scan Increment1 nm
Cuvette Types16 mm round
Barcode RecognitionFull support for Spectroquant® pre-filled tubes and reagent sets
AQA LevelsAQA 1 (wavelength verification), AQA 2 (system performance verification), AQA 3 (matrix interference screening)
Data Storage1000 measurement results
Interfaces1× USB-A, 1× USB-B, 1× RS-232
DisplayBacklit graphical LCD
LanguagesEnglish, German, Spanish, French, Italian, Simplified Chinese
IP RatingIP31
Operating Temperature+10 °C to +35 °C
Dimensions404 × 197 × 314 mm (L × H × W)
Weight~3.7 kg (without battery)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelDR1010
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelDR2800
Instrument TypeLaboratory & Field Water Quality Analyzer
Wavelength Range340–900 nm
Bandwidth5 nm
Optical Detection PrincipleAbsorbance-based Photometric Analysis
Readout ModesTransmittance (%T), Absorbance (A), Concentration (mg/L, ppm, etc.)
Wavelength SelectionAutomatic (method-driven)
Wavelength CalibrationAuto-calibrating via internal reference
Data Storage Capacity500 test records (including date, time, sample ID, operator code, result)
Power OptionsRechargeable Li-ion battery or universal AC adapter (100–240 V, 47–63 Hz)
Operating Environment10–40 °C, ≤90% RH (non-condensing)
Weight4.06 kg (instrument only), 4.38 kg (with battery)
InterfaceUSB 1.1
DisplayTouchscreen LCD with Chinese/English language support
Sample Adapters IncludedA-type (1-cm square cuvettes), B-type (multi-path/flow-through cells), C-type (1-inch round vials & ampoules)
Preprogrammed Methods>240 Hach-certified colorimetric water quality methods
Barcode RecognitionYes (compatible with Hach TNTplus® pre-filled reagent vials)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
TypeLaboratory Digestion Block
ModelDRB200
Wavelength610 nm
Measurement Ranges0.7–40, 3–150, 20–1500, 200–15000 mg/L COD
Accuracy≤ ±10%
Repeatability≤ ±5%
LOD0.7 mg/L
Digestion Time20 min or 2 h (programmable)
Batch Capacity15 or 30 samples (configurable via heating block options)
Temperature Range37–165 °C
Temp Stability±2 °C
Pre-stored ProgramsCOD (150 °C, 120 min), plus multiple fixed-temp/time profiles (100/105/150/165 °C, 30/60/120/240/480 min)
Power100–240 V, 50/60 Hz
Operating Environment10–45 °C, ≤90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck Millipore
OriginGermany
ModelTR320 / TR420 / TR620
DisplayLCD with real-time temperature & timer
CapacityTR320: 12 × 16 mm tubes
TR420/TR62024 × 16 mm tubes (TR620: dual independent 12-position blocks)
Temperature RangeTR320: 100–148 °C
TR420/TR620RT–170 °C
Temperature Accuracy±1.0 °C
Inter-zone Uniformity±1.5 °C vs setpoint
Built-in Programs7 preconfigured (e.g., 148 °C/20 min for COD, 120 °C/60 min for TOC, 100 °C/60 min for Ag/AOX)
Custom ProgramsTR420/TR620 support up to 8 user-defined protocols (0–180 min, 1 °C resolution)
Power Supply115–230 V~, 50/60 Hz
Dimensions (H×W×D)180 × 256 × 307 mm
WeightTR320: 2.85 kg
TR420/TR6203.6 kg
Optional AccessoriesExternal Pt100 temperature probe, PC interface cable for AQA documentation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
ModelPCII
Weight230 g
Optical Range0–2.5 ABS
Operating Temperature10–50 °C
Relative Humidity0–90 % RH
PowerAAA alkaline batteries
IP RatingSubmersible up to 0.9 m for 30 min
Data Storage10 recent measurements
DisplayBacklit LCD with battery indicator
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMyratek
OriginUSA
ModelPortable SS Sentry M-2
Instrument TypePortable
Measurement Range0–30,000 mg/L (or 0–1,500 mg/L selectable)
Accuracy±3% of reading or ±20 mg/L, whichever is greater
Sensitivity1 mg/L (≤1,000 mg/L), 10 mg/L (1,001–9,999 mg/L), 100 mg/L (≥10,000 mg/L)
Repeatability±0.5%
Drift<1% per year
Operating Temperature0–65°C
Probe DiagnosticAutomatic self-diagnostic
OutputRS-232 serial interface
Data Storage50 records with timestamp
DisplayUV-resistant graphical LCD with adjustable backlight contrast
Sensor Cable Length6.0 m
Ambient Operating Conditions–20 to +70°C, 0–100% RH
Enclosure RatingIP66
Housing MaterialsEpoxy, polyurethane, PVC
Maximum Pressure Rating100 PSI
Shipping Weight~1.8 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0