| Brand | Aurora |
|---|---|
| Origin | USA |
| Model | 1200 Plus |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman and D₂ Lamp (1 kHz, Smith-Hieftje mode) |
| Wavelength Range | 185–900 nm |
| Atomizer Temperature Range (GFAAS) | Room Temperature to 3000 °C (programmable) |
| Heating Rate (GFAAS) | Up to 3800 K/s |
| Auto-sampler | Optional XYZ Robotic Sampler with On-line Pre-concentration (up to 100×) |
| Lamp Mount | 6-position Rotating Lamp Tower (4 standard + 2 high-intensity lamp power supplies) |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, electronic signature support, GLP/GMP data integrity features |
| Brand | Anasys |
|---|---|
| Origin | USA |
| Model | nanoIR2-FS |
| Instrument Type | Laboratory Benchtop System |
| Core Principle | Photothermal Induced Resonance (PTIR) Coupled with Atomic Force Microscopy (AFM-IR) |
| Spectral Range | 1000–4000 cm⁻¹ (Standard Tunable Quantum Cascade Laser Source) |
| Spatial Resolution | <10 nm |
| Spectral Acquisition Speed | <3 s per spectrum |
| Data Sampling Interval | Adjustable down to 0.25 cm⁻¹ (FT-based spectral reconstruction) |
| Sample Mode | Ambient or Controlled Environment (N₂-purged optional) |
| Compatible Chemometrics Software | Anasys IR-Spectra™ (with NIST-compatible spectral libraries, ASTM E1421-22 compliant preprocessing) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Cora 5001 |
| Detector Type | CMOS |
| Laser Class | Class 1 |
| Safety Interlock | Integrated shutter-based activation (laser only active when sample chamber is fully closed) |
| Optical Architecture | Monolithic aluminum optical bench, no moving parts |
| Focus Mechanism | Motorized auto-focus with real-time signal optimization |
| Excitation Options | Dual-wavelength “Dual-Core Raman” configuration available (e.g., 785 nm and 1064 nm) |
| Sample Compatibility | Solids (tablets, films, crystals), liquids (in vials of circular/square/rectangular cross-section), powders, pastes |
| Accessories | Magnetic sample holders, universal vial adapters, solid-sample stage with quick-lock positioning |
| Compliance | IEC 60825-1:2014 (Class 1 laser product), CE marked, RoHS compliant |
| Software | Cora Suite v3.x with spectral library matching (≥10,000 reference spectra), GLP-compliant audit trail, FDA 21 CFR Part 11 optional module |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | ZEEnit 700P |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave holographic grating (1800 grooves/mm) |
| Optical System | Dual-beam with automatic single/dual-beam switching |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp + Triple-magnetic-field Zeeman effect |
| Graphite Furnace | Transversely heated, temperature range: room temp to 3000 °C, max heating rate: 3000 °C/s |
| Autosampler | 108-position, programmable |
| Dimensions | 1200 × 480 × 600 mm |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Miniflex 600 |
| X-ray Tube Power | 600 W |
| Dimensions (W×H×D) | 560 × 700 × 395 mm |
| Weight | 80 kg |
| Goniometer Accuracy | ±0.01° 2θ |
| Safety | Interlocked X-ray shutter with automatic beam cutoff during sample loading |
| Detector | Standard scintillation counter |
| Sample Stage | Manual stage standard |
| Software Suite | PDXL (with ICDD PDF-4+ database), Qualitative & Quantitative Analysis modules, Multi-scan acquisition, Dust-specific quantification (e.g., respirable crystalline silica per ISO 16258-1, NIOSH 7500) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | Nexera LC-40 |
| Application Scope | General-purpose analytical laboratory use |
| Flow Rate Range | Up to 5.0 mL/min |
| Maximum Operating Pressure | 130 MPa (1300 bar) |
| Flow Accuracy | ≤0.1% RSD |
| Injection Volume Range | 0.1–100 µL |
| Sample Tray Capacity | Up to 216 positions (with optional 2nd tray) |
| Column Oven Temperature Range | 4–85 °C |
| UV-Vis Detection Wavelength Range | 190–800 nm |
| Data Acquisition Rate | Up to 125 Hz |