Spectroscopy Instruments
Filter
Showing 541–570 of 1322 results
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGA-E50 |
| Instrument Type | Flame–Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Safety Features | Over-Temperature Alarm, Low Gas Pressure Alert, Graphite Tube Break/Loose Clamp Detection |
| Automated Functions | Self-Check at Startup, Automatic Slit Adjustment, Peak Search, Lamp Positioning |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGF-U |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Compliance | Fully aligned with 100+ national and industry standards for AFS analysis (e.g., GB, HJ, GBZ/T, SL) |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGF-V2 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Gravity-based |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | HGF-V3 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Liquid Disposal | Gravity-driven (Static) |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controllers (MFCs) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Se, Pb, Bi, Sb, Te, Sn < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGF-V4 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Gravity-driven (Static) Drainage |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controllers (MFCs) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGF-V9 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Disposal | Gravity-driven (Static) Drainage |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controllers (MFCs) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HGLF |
| Instrument Type | Hyphenated LC-AFS System |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Gravity-Driven Static Drainage |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Digital Mass Flow Controllers |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits (As, Se, Pb, Bi, Sb, Te, Sn) | < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | 50–450 °C |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | LC-AFS6000 |
| Instrument Type | LC–AFS Hyphenated System |
| Sample Introduction | Peristaltic Pump & Syringe Pump (Dual Mode) |
| Detectable Elements (Total Analysis) | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Detectable Elements (Speciation) | As, Hg, Se, Sb (and associated species, e.g., As(III), As(V), MMA, DMA, iAs, MeHg, EtHg, SeCys, SeMet) |
| Patented Gas–Liquid Separation | ZL 201820830427.8 |
| Patented LC–AFS Switching Module | ZL 201420280550.9 |
| Software Platform | Windows 7/8/XP Compatible |
| Data Export | Native Excel (.xlsx) Integration |
| Automation Interface | Standard RS-232/USB for LC Autosampler Coupling |
| Flame Monitoring | Integrated Argon–Hydrogen Flame Viewing Window |
| Electrical Architecture | Segregated High/Low Voltage Design with Modular PCB Layout |
| Compliance Support | ASTM D5762, ISO 17294-2, USP <232>/<233>, EPA Method 1638, GB/T 22105.1–2008 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LC-AFS6500 |
| Instrument Type | LC–AFS Hyphenated System |
| Sample Introduction | Sequential Injection Pump |
| Target Elements (Total Analysis) | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Target Elements (Speciation) | As, Hg, Se, Sb |
| UV Digestion Unit | Integrated, Dual-mode (UV/Non-UV), Auto-switching Valve Control |
| LC Pump | Imported German Knauer Micro High-Pressure Binary Gradient Pump |
| Autosampler Capacity | 183-position Rotating Tray |
| Atomizer | Shielded Quartz Furnace with Ar–H₂ Flame |
| Gas Control | Intelligent Pneumatic System with Self-diagnosis & Flow Regulation |
| Exhaust Treatment | Integrated Activated Carbon Trap |
| Software | Windows-compatible Control Suite with Bidirectional LC & AFS Instrument Control, CFR Part 11–Ready Audit Trail, Excel Export, and Chromatographic Data Integration |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | LC-AFS9530 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Detectable Elements (Speciation) | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Zn, Ge, Au |
| Speciation Capabilities | Inorganic/organic As (e.g., As(III), As(V), MMA, DMA), Hg species (e.g., Hg²⁺, MeHg⁺, EtHg⁺), Se species (e.g., Se(IV), Se(VI), SeMet, SeCys) |
| UV Digestion Mode | On-line, switchable between UV and non-UV pathways |
| Chromatographic Modes | Isocratic and gradient elution |
| Column Temperature Control | Integrated, programmable (ambient to 80 °C) |
| Dual Lamp Holder | Supports simultaneous pre-heating of two hollow cathode lamps |
| Software Control | Unified workstation for LC module, UV digestion, hydride generation, AFS detection, and data processing |
| Automation Compatibility | Compatible with third-party HPLC autosamplers for unattended operation |
| Arsenic(V) Analysis Time (Isocratic) | <7 min |
| Column Equilibration Optimization | Reduced solvent consumption and column stress during method re-equilibration |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LC-AFS9560 |
| Price Range | USD 70,000 – 85,000 |
| Instrument Type | Hyphenated LC-AFS System |
| Sample Introduction | Dual Sequential Injection Pumps |
| Detectable Elements (Speciation & Total) | As, Hg, Se, Pb, Ge, Sn, Sb, Bi, Cd, Te, Zn, Au |
| Regulatory Compliance | Fully aligned with GB 5009.11–2023 (inorganic arsenic), GB 5009.17–2023 (methylmercury), and ISO/IEC 17025 method validation requirements |
| Software Architecture | Integrated workstation with GLP-compliant audit trail, electronic signature support per FDA 21 CFR Part 11 |
| Hardware Integration | Modular LC unit with integrated UV post-column digestion, column oven, six-port injection valve, hydride/vapor generation, and dual-stage membrane-based gas–liquid separation |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PMA-12 Series |
| Spectral Range | 200 nm to 950 nm |
| Detector Type | Back-Thinned CCD Linear Array |
| Optical Design | Czerny-Turner |
| F-number | f/4 |
| Spectral Resolution | < 2 nm (verified with Hg/Ar emission lines) |
| Pixel Count | 1024 channels |
| Pixel Size | 24 µm |
| Active Sensor Area | 2.928 mm |
| Cooling Temperature | −15 °C |
| Read Noise | 16 electrons (rms) |
| Dark Current | 75 electrons/scan (at −15 °C, 20 ms integration) |
| Integration Time | 19 ms to 64 s |
| A/D Resolution | 16-bit |
| Input Fiber | Bundled fiber, φ1 mm core, φ12 mm stainless-steel sheath, 1.5 m length |
| Fiber Coupling | SMA 905 connector |
| Trigger Interface | TTL-compatible, high-impedance input |
| Data Interface | USB 2.0 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | HanHe |
|---|---|
| Origin | Shandong, China |
| Model | H-L1900 |
| Spectral Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Photometric Accuracy | ±0.3%T (0–100%T), ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs) |
| Baseline Drift | ±0.002 A/h |
| Baseline Flatness | ±0.002 A |
| Stray Light | ≤0.1%T |
| Photometric Repeatability | ≤0.15%T (0–100%T), ≤0.001 Abs (0–0.5 Abs), ≤0.002 Abs (0.5–1.0 Abs) |
| Detector | Imported Silicon Photodiode |
| Light Sources | Long-life Deuterium Lamp & Tungsten Halogen Lamp |
| Display | 128×64 Dot-Matrix LCD |
| Data Interface | USB Port |
| Dimensions | 460 × 380 × 180 mm |
| Weight | 18 kg |
| Brand | HanHe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | H-L72 Series |
| Spectral Range | 350–1050 nm |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ≤1 nm |
| Photometric Accuracy | Contact Technical Support |
| Baseline Drift | See Detailed Specifications |
| Baseline Flatness | Contact Technical Support |
| Brand | HANNA |
|---|---|
| Origin | Italy |
| Model | HI6000 |
| Module Options | pH/ORP, pH/ORP/ISE, Conductivity (EC), Dissolved Oxygen (DO) |
| Calibration Points | up to 5-point for pH, ISE, and EC |
| Display | 7" capacitive touchscreen (17.8 cm) |
| Data Logging Capacity | 1,000,000 points with timestamp |
| Connectivity | USB-A, USB-C, Ethernet, Wi-Fi, FTP, Email export |
| Compliance Support | GLP-compliant logging, calibration traceability, user profiles (10), audit-ready data export (.CSV), embedded web server |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Measurement Principle | MEMS-based Micro-FPI (Fabry–Pérot Interferometer) |
| Wavelength Range | 1750–2150 nm |
| Sampling Mode | Diffuse Reflectance |
| Detector Type | InGaAs |
| Spectral Resolution (FWHM) | ≤20 nm (≤1% of center wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Measurement Time per Sample | <30 s |
| Light Source Lifetime | 5000 h |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Integrated Computing Platform | Microsoft Surface Tablet |
| Software Suite | MEMS Chemometrics Platform (Model Management, Quantitative Analysis, Audit Trail, User Permissions) |
| Brand | HeadWall |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | MV.C NIR |
| Price Range | USD 70,000 – 210,000 (FOB) |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based |
| Spectral Range | 900–1700 nm |
| Number of Spectral Bands | 214 |
| Frame Rate | 547 fps |
| Optical Design | Offner Holographic Concave Grating |
| Data Interface | Gigabit Ethernet |
| Enclosure Rating | IP54 |
| Onboard Processing | Real-time spectral classification engine |
| Software Compatibility | perClass Mira, HeadWall HyperSpectra Studio |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Hellma NexIII Cuvette Cleaning Solution |
| Instrument Category | Circular Dichroism (CD) Spectrometry |
| Price Range | USD 260–1,300 (ex-works, excluding VAT & shipping) |
| Brand | Hengmei |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HM-MD |
| Spectral Bandwidth | 4 nm (2 nm optional) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 190–1100 nm |
| Photometric Range | 0–200% T, −0.3–3 A |
| Stray Light | ≤0.1% T |
| Photometric Accuracy | ±0.5% T, ±0.004 Abs (0–0.5 A) |
| Photometric Repeatability | ±0.5% T, ±0.004 Abs (0–0.5 A) |
| Baseline Stability | ±0.002 Abs at 500 nm (3 min) |
| Detector | Imported Silicon Photodiode |
| Monochromator | Czerny-Turner with Holographic Blazed Grating (1200 lines/mm) |
| Display | 7-inch TFT-LCD Touchscreen (1024 × 768) |
| Connectivity | USB, Wi-Fi (standard), Bluetooth (standard), optional PC software (Yokelab), cloud integration via YOKE@Clouddata |
| Data Storage | 2000 spectra, 96 calibration curves |
| Scan Speed | up to 3000 nm/min |
| Lamp Switching | Automatic (default 340 nm, user-configurable) |
| Brand | Hiperscan |
|---|---|
| Origin | Germany |
| Model | Apo-Ident |
| Wavelength Range | 1000–1900 nm |
| Wavelength Resolution | 10 nm |
| Wavelength Stability | ±1 nm |
| Measurement Time | <15 s |
| Operating Temperature | 15–35 °C |
| Dimensions | 203 × 279 × 219 mm |
| Weight | 5.2 kg |
| Power Supply | 230 V~, 50/60 Hz, 60 W |
| Interface | USB Type-B |
| Software | QuickStep Apo-Ident |
| OS Compatibility | Windows Vista/7/8/10 (excluding Starter editions), Linux, macOS |
| Minimum System Requirements | 1 GB RAM, Pentium 1.6 GHz CPU, 0.5 GB disk space |
| Brand | HiperScan |
|---|---|
| Origin | Germany |
| Model | Finder SD |
| Spectral Range | 1000–1900 nm |
| Spectral Resolution | 10 nm |
| Stray Light | ≤0.20% |
| Measurement Time | <5 s (average of ≥500 scans), configurable from 1–15 s |
| Detector | Single-element uncooled InGaAs |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Photometric Reproducibility | ±0.1% |
| SNR | >2000:1 (≥2000 scans), >1000:1 (≥500 scans) |
| Photometric Linearity (max/RMS) | ≤1% / <1% |
| Light Source | Tungsten-halogen lamp |
| Sampling Interface | Diffuse reflectance probe (23 mm aperture) |
| Thermal Stability | Yes |
| Dimensions (W×D×H) | 225 × 235 × 385 mm |
| Weight | 9 kg |
| Interface | USB Type-B (with optional auxiliary I/O for motor control or sensor input) |
| Operating Temperature | 15–35 °C (Type 55) or 5–30 °C (Type 50) |
| Storage Temperature | −20 to +60 °C (non-condensing) |
| IP Rating | IP65 |
| Power Supply | 100–240 VAC ±10%, 50–60 Hz |
| Power Consumption | 78 W (warm-up), 36 W (operation), 5 W (standby) |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Scanning Speed | Up to 60,000 nm/min |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Excitation Source | Xenon Arc Lamp |
| Monochromator Type | Dual Grating |
| Detection Mode | Photon Counting with PMT |
| Dimensions & Weight | Approx. 2/3 volume and 30% less mass vs. F-4500 model |
| Software Compliance | FDA 21 CFR Part 11 (Audit Trail, Electronic Signature, User Access Control) |
| Linear Dynamic Range | 6 decades for calibration curve generation |
| Phosphorescence Measurement Capability | Extended time-gated detection up to seconds scale |
| Optional Module Support | Report Generator, Temperature-Controlled Cell Holder, Polarization Accessories, Microvolume Adapters |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Flame AAS |
| Model | HD-AAS4H |
| Wavelength Range | 185–900 nm |
| Monochromator | Czerny-Turner enhanced optical system |
| Grating Density | 1800 lines/mm |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Accuracy | ≤ ±0.1 nm |
| Wavelength Repeatability | ≤ ±0.025 nm |
| Resolution | 0.2 nm (Cu 324.7 nm, 0.2 nm bandwidth) |
| Baseline Drift | 0.003 ABS/30 min (static), 0.005 ABS/15 min (dynamic) |
| Detector | Hamamatsu photomultiplier tube |
| Background Correction | Deuterium lamp |
| Characteristic Concentration (Cu) | 0.025 µg/mL/1% |
| Detection Limit (Cu) | 0.006 µg/mL |
| Precision (RSD) | ≤ 0.5% |
| Atomizer | Titanium 0.5 mm × 100 mm burner head |
| Nebulizer | High-efficiency glass nebulizer with metal cap |
| Spray Chamber | Corrosion-resistant all-plastic chamber |
| Safety System | Real-time acetylene leak detection, flame-out monitoring, gas pressure interlock, automatic shutdown |
| Lamp System | Motorized turret for 4/6/8 lamp positions |
| Data Interface | RS232, USB |
| Software | Windows-compatible AAS control suite with dual-language UI (EN/CN), remote calibration support, GLP-compliant audit trail, multi-format export (CSV, PDF, Excel) |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | CCD-based Multi-Channel Array |
| Focal Length | 400 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–800 nm |
| Analog-to-Digital Resolution | 16-bit per pixel |
| Optical Architecture | Paschen-Runge Mount with Rowland Circle Design |
| Vacuum System | Intermittent Vacuum Maintenance |
| Compliance | ASTM E415, ISO 11573, GB/T 4336 (Chinese National Standard for Spark OES) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualog® |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 5 nm |
| Optical Resolution | 0.58 nm |
| Sensitivity | 20,000:1 (SNR, RMS, water Raman at 350 nm excitation, 30 s integration) |
| Wavelength Accuracy | ±1.0 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | Adjustable from 1 to 64 nm |
| Optical Resolution | 1 nm |
| Detection Sensitivity | Single-Photon Counting |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | DeltaPro |
| Dispersion Element | Grating |
| Slit Width / Spectral Bandpass | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Wavelength Accuracy | Not Specified |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Duetta |
| Wavelength Range (Fluorescence) | 250–1100 nm |
| Detection Technology | Back-Illuminated CCD |
| Sensitivity (Water Raman S/N) | >6000:1 |
| Dispersion Element | Holographic Grating |
| Slit Width / Spectral Bandpass | Variable, software-controlled |
| Wavelength Accuracy | ±0.5 nm |
| Internal Correction | Automated primary and secondary inner-filter effect compensation |
| Core Technology | A-TEEM™ (Absorbance-Transmitted Excitation-Emission Matrix) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Duetta |
| Wavelength Range (Fluorescence) | 250–1100 nm |
| Spectral Bandwidth (Slit) | 1–20 nm |
| Optical Resolution | 1 nm |
| Sensitivity (Water Raman RMS) | 6000:1 |
| Wavelength Accuracy | ±1 nm |
| Dispersion Element | Grating |
| Detector | CCD |
| Measurement Modes | Simultaneous Fluorescence & Absorbance |
| A-TEEM™ Capability | Yes |
| Auto Inner-Filter Correction | Yes |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EV 2.0 |
| Detector Type | CCD |
| Spectral Range | 200–1050 nm |
| Dynamic Range | >3000:1 |