Spectroscopy Instruments
Filter
Showing 931–960 of 1315 results
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Spectral Resolution | 10 cm⁻¹ |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Reproducibility | <1 cm⁻¹ |
| Laser Wavelength | 1064 nm |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | 1200:1 (RMS), 15,000:1 (RMS with Background Subtraction) |
| Wavelength Accuracy | ±2 nm |
| Excitation Source | Pulsed Xenon Arc Lamp |
| PMT Detection Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Software | FL Analyst (English & Chinese GUI) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 1.0–20 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | >450:1 (Peak-to-Peak) |
| Wavelength Accuracy | ±2.0 nm |
| Excitation Source | Xenon Arc Lamp |
| Standard PMT Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Spectral Correction | Full-mode (Excitation/Emission/Spectral Response) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Structure | Single-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.05% T |
| Automation Level | Automatic Wavelength Scanning |
| Display | 5-inch TFT Color Touchscreen |
| Optical Platform | Integrated Die-Cast Optical Base |
| Compliance | Designed for GLP-compliant routine analysis |
| Connectivity | USB and RS-232 interfaces for PC control and printer output |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV1200 |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.3 nm |
| Stray Light | ≤0.05% |
| Display | 7-inch HD capacitive touchscreen |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV2500 |
| Price Range | USD 9,800–13,900 (FOB Shanghai) |
| Optical Design | Dual-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scan |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | ≤0.05% T at 220 nm and 340 nm |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | UV2600 |
| Price Range | USD 9,800–13,900 (FOB Shanghai) |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Scanning | Motorized, Software-Controlled |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, 5 nm (Auto-Selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | <0.010% T (at 220 nm, NaI |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy DC Arc |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Repeatability | ≤1.5% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm (at 200 nm) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Precision (RSD) | ≤1.5% |
| Stability (Drift) | ≤2% |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy Plus |
| Instrument Type | Full-Spectrum Direct-Reading ICP Optical Emission Spectrometer |
| Detection Limit (Zn @ 213.856 nm) | < 0.1 µg/L |
| Precision (RSD) | ≤ 0.5% |
| Long-Term Stability (RSD, 4h) | ≤ 1.0% |
| Wavelength Range | 130–1100 nm |
| Optical Resolution | 0.005 nm @ 200 nm |
| Detector | Custom 28 × 28 mm CMOS sensor with 3.38 million effective pixels |
| Readout Speed | >10× faster than conventional CID/CCD detectors |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy7 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit (Zn at 213.856 nm) | <0.1 µg/L |
| Precision (RSD) | ≤1.0% |
| Stability (RSD over 4 hours) | ≤1.0% |
| Wavelength Range | 165–1100 nm |
| Optical Resolution | ≤0.007 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Detection Limit (Ca at 396.847 nm) | 0.155 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (2-hr drift) | ≤1.0% |
| Optical Resolution | 0.005 nm |
| RF Generator Cooling | Air-Cooled |
| Plasma Torch Assembly | Ceramic RF Load Coil |
| Optical System | Echelle Grating with ICCD Detector |
| Compliance | ASTM D1976, ISO 11885, USP <233>, EPA Methods 200.7 & 6010E |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OLED/QLED Device Lifetime Testing System |
| Price Range | USD 14,000 – 28,000 |
| Channel Capacity | 32 / 64 / 128 (scalable to 512 channels) |
| Operating Modes | Constant Current, Constant Voltage, Constant Luminance (user-selectable) |
| Current Output Range | 0.03 µA – 100 mA (accuracy ±1% of reading) |
| Voltage Output Range | 1.0 – 20 V (accuracy <±1%) |
| Device Architecture Support | Bottom-emission, top-emission, inverted, and standard stack configurations (customizable per device architecture) |
| Substrate Compatibility | Standard 5 cm × 5 cm |
| Temperature Range | RT+10°C to 100°C (standard) |
| Environmental Options | Inert atmosphere testing (N₂/Ar), glovebox-integrated operation, UPS-backed power supply |
| Software Platform | LabVIEW-based control and data acquisition with real-time logging, timestamped event tracking, and export-ready CSV/Excel output |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Antaris II |
| Instrument Type | Laboratory |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–12000 cm⁻¹ |
| Scan Speed | 5 scans/sec |
| Data Sampling Interval | 2 cm⁻¹ |
| Measurement Modes | Transmission, Diffuse Reflectance, Transflectance, Transdiffuse |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Antaris MX |
| Instrument Type | Online/At-line Portable FT-NIR Analyzer |
| Principle | Fourier Transform Near-Infrared Spectroscopy (FT-NIR) with Real-time Process Integration |
| Wavelength Range | 4000–12000 cm⁻¹ |
| Scan Speed | 5 scans per second |
| Spectral Resolution | 2 cm⁻¹ (data sampling interval) |
| Measurement Modes | Transmission, Transflection, Diffuse Reflectance |
| Chemometrics Software | TQ Analyst v9+ and RESULT v3.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Antaris Target In-Process Mixing Monitor |
| Instrument Category | Online Near-Infrared Spectrometer |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 5300–7500 cm⁻¹ |
| Scan Speed | 12.5 scans/second |
| Spectral Sampling Interval | 0.7 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biomate 160 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | DXR3xi |
| Instrument Category | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Excitation Wavelength | 455 nm (optional lasers available) |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution Pro |
| Instrument Configuration | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | Selectable 0.5, 1.0, 1.5, 2.0, or 4.0 nm |
| Wavelength Accuracy | ±0.20 nm at 546.07 nm (Hg emission line) |
| Wavelength Repeatability | Standard deviation <0.05 nm over 10 consecutive measurements |
| Stray Light | ≤0.4% T at 198 nm (KCl), ≤0.032% T at 220 nm (NaI), <0.01% T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FoodDefender RM |
| Instrument Category | Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM, full range) |
| Spatial Resolution | 7–10.5 cm⁻¹ (Raman), 4 cm⁻¹ (IR-equivalent reference) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans on homogeneous sample |
| Weight | 800 g |
| Dimensions | 19.3 × 10.7 × 4.4 cm |
| Laser Output Power | Adjustable (75 / 125 / 250 mW) |
| Numerical Aperture | NA = 0.23 |
| Working Distance | 17 mm |
| Spot Size | 0.14–1.8 mm |
| Integration Time | Manual or auto mode (minimum 5 ms) |
| Delay Time | Configurable (0–120 s) |
| Power Supply | Rechargeable Li-ion battery or two 123A alkaline cells |
| Operating Temperature | −20 °C to +40 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS™ 140 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 325–1100 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS 180 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 40 |
| Optical Detector | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 50 |
| Optical Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Automation | Automatic Wavelength Scanning & Calibration |
| Sample Compartment | Removable, Washable Interior Liner |
| Display | 7-inch HD Touchscreen Interface |
| Method Management | Pre-programmed Smart Start Methods |
| Compatibility | Cuvettes (10 mm pathlength standard), Test Tubes, Microvolume Adapters (optional) |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | iCAP 7000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Price Range | USD 135,000 – 162,000 (estimated FOB UK) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | iCAP PRO |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | Not Specified |
| Precision (RSD) | Not Specified |
| Stability | Not Specified |
| Wavelength Range | Not Specified |
| Optical Resolution | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Produced |
| Model | iCAP PRO Series ICP-OES |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | microPHAZIR GP |
| Principle | Portable, Non-Destructive NIR Spectroscopy |
| Weight | 1.3 kg |
| Spectral Range | 1600–2400 nm |
| Measurement Time | ≤3 s (configurable) |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory |
| Data Transfer | USB (text-based .csv/.txt) |
| Operating Temperature | 5–40 °C |
| Battery | Rechargeable Li-ion with Hot-Swap Capability |
| Enclosure | Dust- and Splash-Resistant High-Impact Polymer Housing |
| Security | Multi-Level Password Protection |
| Standard Accessories | Rugged Waterproof Carry Case, Li-ion Battery Pack, 110/220 VAC Charger, Lanyard |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | microPHAZIR PC Carpet |
| Principle | Portable, On-Site NIR Spectroscopy |
| Weight | 1.25 kg |
| Measurement Time | 1.5 s |
| Light Source | Tungsten-Halogen Lamp |
| Display | Color LCD |
| Data Interface | USB to PC |
| Battery | Rechargeable Li-ion (≥5 h runtime, <2 h recharge time, dual-battery configuration) |
| Enclosure | Dust- and Splash-Resistant Engineering Plastic |
| Preloaded Library | Carpet Fiber Identification Database |
| Security | Multi-Level Password Protection |
| Calibration | Factory-Calibrated, Ready-to-Use Out-of-Box |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR PC Plastics |
| Principle | Portable, On-Site NIR Spectroscopy |
| Spectral Range | 1600–2400 nm (6250–4100 cm⁻¹) |
| Measurement Time | <3 s |
| Sampling Mode | Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | High-Strength Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory with USB Export |
| Interface | USB |
| Operating Temperature | 5–50 °C (non-condensing) |
| Power Supply | Dual Swappable Li-ion Batteries (4.5 h runtime), AC Adapter & Charger Included |