| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-10 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | UV-VIS: 0.2, 0.5, 1, 2, 3, 5 nm |
| NIR | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-15 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | UV-VIS: 0.2, 0.5, 1, 2, 3, 5 nm |
| NIR | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Integrating Sphere Diameter | 150 mm |
| Optical Design | Dual-beam, dual-grating, dual-detector architecture |
| Detector Configuration | Separate optimized detectors for UV/VIS and NIR ranges |
| Software Compatibility | Windows 7/10 |
| Data Export Formats | TXT, CSV, XLSX |
| Compliance Standards | GB/T 2680-2021, JGJ/T 151-2008, ISO 9050:2003, GB/T 22476-2008, GB/T 36261-2018, GB/T 25261-2010, JG/T 235-2014, JGJ/T 287-2014, GJB 798-90, GJB 2502.2-2006 |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-6 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | [UV-VIS] 0.2, 0.5, 1, 2, 3, 5 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INSA Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 8000–350 cm⁻¹ (extendable to 12800–4000 cm⁻¹ in NIR |
| Spectral Resolution | 0.2 cm⁻¹ |
| Scan Speed | 2.5–60 kHz |
| Signal-to-Noise Ratio (SNR) | 40,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | < ±0.1 cm⁻¹ |
| Vacuum Level | ≤ 0.2 mbar |
| Optical Design | All-metal vacuum-sealed cast-aluminum interferometer housing with independent optical chamber |
| Brand | INSION |
|---|---|
| Origin | Germany |
| Model | 2C UV VIS |
| Optical Architecture | Single-beam |
| Detector Type | Photodiode Array |
| Spectral Range | 2 × 350–1050 nm |
| Wavelength Accuracy | < 10 nm FWHM |
| Spectral Resolution | < 10 nm FWHM |
| Sensitivity | > 2.0 × 10¹⁵ counts·nm/W·s at 650 nm |
| Optical Interface | Dual SMA 905 connectors |
| Calibration | Factory-calibrated, no user recalibration required |
| Mechanical Stability | Solid-state design, no moving parts |
| Operating Temperature Range | 5–40 °C |
| Dimensions | ≤ 65 × 45 × 25 mm |
| Weight | < 120 g |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | InverTau |
| Pricing | Upon Request |
| Dispersive Element | Filter-Based |
| Resolution | 4096 × 4096 |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | IQ-Thermo |
| Pricing | Upon Request |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 7 nm |
| Spatial Resolution (IFOV) | 512 pixels |
| Field of View (TFOV) | 31° |
| LWIR Band | 7.5–13.5 µm |
| IR Detector Resolution | 640 × 512 px |
| Thermal Sensitivity | ≤0.03 °C (30 mK) @ 30 °C |
| Temperature Range Options | −25 to +150 °C or +40 to +550 °C (optional up to +1500 °C) |
| Frame Rate Options | 9 / 30 / 60 Hz |
| Optical Aperture | f/1.7 |
| Spectral Bands | 204 (with optional binning: 2× or 3×) |
| GPS Integration | Yes (geotagged data cubes) |
| Enclosure Rating | IP65 |
| Data Interfaces | USB 3.0, GigE, Wi-Fi |
| Output Formats | CSV, radiometric JPEG, non-radiometric JPEG, radiometric video, AVI, MP4 |
| Software Features | SAM algorithm, ROI temperature profiling, isotherm mode, thermal 3D surface mapping, report generation |
| Brand | Spectrolight |
|---|---|
| Origin | Switzerland |
| Model | IRsweep IRis-F1 |
| Instrument Type | Laboratory Benchtop Laser-Based Infrared Spectrometer |
| Light Source Technology | Dual Quantum Cascade Laser (QCL) Frequency Comb |
| Time Resolution | 1 µs |
| Spectral Resolution | 0.25–0.5 cm⁻¹ |
| Spectral Range | Mid-Infrared (Typical 1,200–3,000 cm⁻¹, configurable) |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Software Environment | IRsweep Control Suite v4.x (Windows-based, FDA 21 CFR Part 11-ready audit trail option) |
| Brand | IRsweep |
|---|---|
| Origin | Switzerland |
| Model | IRis-F1 |
| Technology | Dual-Comb Quantum Cascade Laser (QCL) Infrared Spectroscopy |
| Time Resolution | 1 µs |
| Spectral Resolution | 0.25–0.5 cm⁻¹ |
| Spectral Range | Mid-IR (typically 1200–2200 cm⁻¹, configurable) |
| SNR | High (optimized for trace-level detection) |
| Sample Compatibility | Solid, Liquid, Gas |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane SCT-320, IsoPlane 160 |
| Focal Length | 320 mm (SCT-320), 203 mm (160) |
| Aperture Ratio | f/4.6 (SCT-320), f/3.88 (160) |
| Spectral Resolution (PMT) | 0.05 nm (SCT-320), 0.10 nm (160) |
| Spectral Resolution (CCD, 1200 gr/mm, 435 nm, 20 µm pixels, 10 µm slit) | 0.08 nm (SCT-320), 0.15 nm (160) |
| Grating Mount | Motorized triple-grating turret with auto-recognition |
| Wavelength Range | UV to mid-IR (193 nm–>5 µm, depending on grating & detector) |
| Optical Coating Options | Acton #1900 enhanced Al (193 nm–mid-IR), protected Ag (>98% avg. reflectance), Au (NIR/SWIR) |
| Detector Compatibility | PIXIS, ProEM, PI-MAX4, NIRvana series |
| Software Platform | LightField v8+ (64-bit), supports LabVIEW, MATLAB, EPICS, and FDA 21 CFR Part 11-compliant audit trail modules |
| Brand | ISPEC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | Analytical System |
| Quotation | Upon Request |
| Instrument Category | Spectral Software & Database Suite |
| Instrument Type | Laboratory-Based |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Brand | Bunkoukeiki (Japan) |
|---|---|
| Origin | Japan |
| Model | IUV-25CP-1 |
| Wavelength Range | ~240 nm (continuous irradiation band) |
| Irradiation Area (Vertical) | 89 mm (5–13 adjustable steps) |
| Irradiation Area (Wavelength Direction) | 80 mm (~240 nm spectral span) |
| Exposure Time | 0.01–1200 s |
| Exposure Steps | 1–13 |
| Light Sources | Deep UV Mercury Lamp (line spectrum) + Xenon Arc Lamp (broadband continuum) |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | easyLIBS |
| Instrument Type | Handheld |
| Integration | Modular |
| Laser Source | Dual-Pulse Nd:YAG, 1064 nm |
| Spot Size | ~300 µm |
| Detection Limit | 1–500 ppm (element-dependent) |
| Weight (system with case) | <7 kg |
| Power Supply | Integrated portable battery pack |
| Software | AnaLIBS (included on dedicated laptop) |
| Optical Collection | Co-aligned laser focusing & plasma signal collection optics |
| Imaging | Built-in CMOS camera for real-time sample surface visualization |
| Fiber Spectrometer Options | User-selectable, multiple wavelength ranges available |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | MEEPLIBS |
| Instrument Type | Online LIBS System |
| Integration | Fully Integrated |
| Spatial Resolution | Down to 4 µm (Standard Apertures: 15 µm and 18 µm) |
| Operating Environment | Ambient Air at Room Temperature (Configurable for Controlled Atmospheres) |
| Laser Source | Q-Switched Nd:YAG, 266 nm UV, Software-Tunable Pulse Energy with Beam Shaping & Attenuation |
| Sample Handling | Motorized XYZ Translation Stage with Real-Time CCD Imaging Feedback |
| Elemental Coverage | H to U (All Elements, Including Light Elements) |
| Sample Preparation | None Required |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | YAG 266 nm, 20 Hz |
| Form Factor | Benchtop |
| Integration | Fully Integrated |
| Laser Type | Q-switched Nd:YAG (4th harmonic) |
| Wavelength | 266 nm |
| Repetition Rate | 20 Hz |
| System Architecture | Modular (4 units, ~30 kg each) |
| Sample Compatibility | Solids, Liquids, Gases, Opaque & Transparent Materials |
| Optical Path | Motorized Focus Adjustment |
| Detection Range | Typically 190–850 nm (configurable per spectrometer module) |
| Compliance | CE-marked, RoHS-compliant |
| Brand | J&M |
|---|---|
| Origin | Germany |
| Model | MSP-400 |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 400–800 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | 0.001% T |
| Automation Level | Automatic Wavelength Scanning |
| Compatibility | Integrates with microscope camera tubes via TIDA interface |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CPL-300 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FI/IR NRS |
| Price | Upon Request |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FP-8000 Series |
| Wavelength Range | 200–750 nm (up to 900 nm or 1010 nm depending on model) |
| Excitation Source | 150 W Xenon Arc Lamp |
| Spectral Bandwidth (Slit) | 1–20 nm |
| Resolution | 1.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Sensitivity (S/N) | >500 (RMS, specified at water Raman peak) |
| Scan Speed | Up to 60,000 nm/min |
| Dynamic Range | >6.5 decades |
| Detection Capability | Phosphorescence lifetime down to 1 ms |
| Dispersion Element | Grating + Order-sorting Filters |
| Accessories Interface | IQ-enabled automatic accessory recognition |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FSV-6000 |
| Measurement Range | 850–3200 cm⁻¹ (expandable to 750–4000 cm⁻¹) |
| Detector | Liquid Nitrogen-Cooled MCT |
| Incident Angle | 28° Michelson Interferometer |
| Optical System | Purgeable (N₂ or dry air) |
| Light Source | High-Intensity Ceramic IR Source |
| Optional Feature | Narrowband VCD-optimized Bandpass Filters |
| Compatibility | Fully Integrated with JASCO FT/IR-4000 & FT/IR-6000 Series as VFT-4000 Expansion Module |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FT/IR-4000, FT/IR-6000 Series |
| Instrument Type | Laboratory Fourier Transform Infrared (FTIR) Spectrometer |
| Wavenumber Range | 7800–400 cm⁻¹ |
| Spectral Resolution | 0.4 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 55,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Sample Compatibility | Up to 300 mm (12″) silicon wafers |
| Measurement Modes | Specular reflectance, transmission, and attenuated total reflectance (ATR) with wafer-specific accessories |
| Compliance | JEITA RC-2001, JEIDA-6301, SEMI F39, ASTM F1597, ISO 14644-1 (cleanroom-compatible operation) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FT/IR-4000, FT/IR-6000 |
| Instrument Type | Laboratory Benchtop FTIR |
| Wavenumber Range | 25,000–10 cm⁻¹ (extended options available) |
| Spectral Resolution | 0.7–0.07 cm⁻¹ |
| Scan Speed | 20 Hz |
| Signal-to-Noise Ratio | 25,000:1 to 55,000:1 |
| A/D Converter | 24-bit |
| Interferometer | Corner-Cube Retroreflector with Real-Time DSP Mirror Control |
| Optical Stability | Active Beam Alignment Compensation |
| Compatibility | Integrated with JASCO IR Microscopes (e.g., IRT-5200, IRT-7200) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 11,500–50 cm⁻¹ |
| Spectral Resolution | 0.4 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 35,000:1 |
| Dimensions | 386 mm (W) × 479 mm (D) × 290 mm (H) |
| Interferometer | Sealed, Thermally & Hygroscopically Stabilized Michelson |
| Scan Speed | Up to 80 spectra/sec |
| Detector Compatibility | MCT, InGaAs, DTGS |
| Sample Compartment Width | 200 mm |
| Software | Spectrum Manager Ver. 2.5 with Auto-Diagnostic & Guided Workflow |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FT/IR-6X / FT/IR-8X |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Spectral Range | 25,000–20 cm⁻¹ |
| Spectral Resolution | 0.07 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 55,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector, peak-to-peak) |
| Interferometer | 28° Michelson with Corner Cube Retroreflectors |
| Light Source | High-intensity Ceramic Source |
| Detector | Temperature-Controlled DLATGS or Optional MCT |
| Beam Splitter Exchange | Automated Beam Splitter (BS) Switching Unit |
| Software | Spectrum Manager™ Ver. 2.5 |
| Compliance | Fully Compatible with ASTM E1421, ISO 18382, USP <1119>, GLP/GMP Data Integrity Requirements (21 CFR Part 11 Ready) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Instrument Type | Laboratory Benchtop |
| FTIR Architecture | Interferometer-Based Michelson Design |
| Wavenumber Range | 7800–400 cm⁻¹ |
| Spectral Resolution | 0.07 cm⁻¹ (unapodized, with He–Ne laser referencing) |
| Signal-to-Noise Ratio | 55,000:1 (at 4 cm⁻¹ resolution, 1 min scan, MCT detector, peak-to-peak) |
| Vacuum Performance | <10⁻³ Pa base pressure, <5×10⁻⁴ Pa during spectral acquisition |
| Optical Path Environment | Fully evacuated sample compartment and interferometer housing |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | IRT-7200 / IRT-5200 / IRT-1000 |
| Instrument Type | Laboratory FTIR Microscope |
| Wavenumber Range | 25,000–10 cm⁻¹ |
| Spectral Resolution | 0.7–0.07 cm⁻¹ |
| Scan Speed | 20 Hz |
| Signal-to-Noise Ratio | 25,000:1 to 55,000:1 |
| Detector Configuration | 16-channel MCT (IRT-7200), single-element MCT + CMOS visual camera (IRT-5200), compact ATR-integrated module (IRT-1000) |
| Optical Interface | Cassegrain objectives (×16, ×32 standard), ATR imaging capability |
| Software | JASCO Spectra Manager™ with mapping, time-resolved imaging, and co-registered spectral–spatial analysis modules |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | J-1500 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Wavelength Range | 163–950 nm (extendable to 1600 nm) |
| Standard Measurement Modes | CD, LD, UV-Vis |
| Optical System | Dual Photoelastic Modulator (PEM) with Vacuum UV-optimized Polarization Optics |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MVS-5000 Series |
| Instrument Architecture | Dual-Wavelength |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 200–2700 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | 1–20 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.0001% (at 220 nm, NaI |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PR-1w |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 3000–200 cm⁻¹ |
| Spectral Resolution | 3 cm⁻¹ per pixel |
| Laser Excitation Wavelength | 785 nm |
| Detector | Uncooled CMOS |
| Interface | USB 2.0 for PC connectivity |
| Measurement Time | ~2–3 minutes per sample |
| Sample Compatibility | Solids, powders, liquids (including through transparent packaging) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | V-630 Bio |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤0.02% T |
| Automation | Motorized Wavelength Scanning |
| Sample Volume Requirement (with 8-position micro-volume rotator) | 4 µL per measurement |
| Temperature Control Option | Peltier-based electronic thermostat (optional) |