Spectroscopy Instruments
Filter
Showing 2071–2100 of 2617 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Manufactured |
| Model | Evolution™ Pro UV-Vis Spectrophotometer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FoodDefender RM |
| Instrument Category | Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM, full range) |
| Spatial Resolution | 7–10.5 cm⁻¹ (Raman), 4 cm⁻¹ (IR-equivalent reference) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans on homogeneous sample |
| Weight | 800 g |
| Dimensions | 19.3 × 10.7 × 4.4 cm |
| Laser Output Power | Adjustable (75 / 125 / 250 mW) |
| Numerical Aperture | NA = 0.23 |
| Working Distance | 17 mm |
| Spot Size | 0.14–1.8 mm |
| Integration Time | Manual or auto mode (minimum 5 ms) |
| Delay Time | Configurable (0–120 s) |
| Power Supply | Rechargeable Li-ion battery or two 123A alkaline cells |
| Operating Temperature | −20 °C to +40 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS™ 140 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 325–1100 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Product Origin | Imported |
| Model | GENESYS 140 Visible Spectrophotometer |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Automation Level | Automatic Wavelength Scanning |
| Connectivity | Integrated Wi-Fi, USB, Ethernet |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GENESYS 150 |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS 180 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | GENESYS 180 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Product Origin | Imported |
| Model | GENESYS 30 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2 nm |
| Stray Light | <0.1% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 40 |
| Optical Detector | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | GENESYS 40 |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 325–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 50 |
| Optical Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Automation | Automatic Wavelength Scanning & Calibration |
| Sample Compartment | Removable, Washable Interior Liner |
| Display | 7-inch HD Touchscreen Interface |
| Method Management | Pre-programmed Smart Start Methods |
| Compatibility | Cuvettes (10 mm pathlength standard), Test Tubes, Microvolume Adapters (optional) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GENESYS 50 |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0% T at 198 nm (KCl), <0.05% T at 220 nm (NaI), <0.03% T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GENESYS™ 140/150 UV-Visible Spectrophotometer |
| Pricing | Available Upon Request |
| Display | 7-inch high-resolution capacitive touch screen |
| Connectivity | Built-in Ethernet |
| Ambient Light Tolerance | Yes — designed for operation with sample compartment open |
| Sample Compartment | Removable, washable base with magnetic positioning and retention |
| Max Cuvette Pathlength | 100 mm |
| Optional Accessories | 8-cell auto-changer, 4-cell changer (for long-path cuvettes), Peltier-controlled single-cuvette holder (20–60 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | GENESYS™ 180 UV-Vis Spectrophotometer (Domestically Manufactured) |
| Quotation | Upon Request |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Optical Design | Double-Beam |
| Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
| Photometric Range | –2 A to +3.5 A |
| Photometric Display Range | –3 A to +5 A |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Wavelength Data Interval | 0.1, 0.2, 0.5, 1, 2, or 5 nm |
| Baseline Flatness | ±0.002 A |
| Stray Light | <1.0%T @ 198 nm (KCl), <0.05%T @ 220 nm (NaI), <0.03%T @ 340 nm (NaNO₂) |
| Noise (RMS, 60 readings @ 500 nm) | ≤0.00020 A at 0 A, ≤0.00030 A at 1 A, ≤0.00040 A at 2 A |
| Detector Type | Dual Silicon Photodiodes |
| Display | 7-inch HD color touchscreen (800 × 1280 px), tilt-adjustable |
| Sample Compartment | Standard 8-cell changer with swappable sample tower |
| Optional Accessories | 4-cell long-path changer (up to 100 mm pathlength), Peltier-controlled single-cell holder (20–60 °C), syringe autosampler, fiber optic probe coupler |
| Connectivity | Dual USB-A ports, Ethernet, Wi-Fi adapter support (optional), USB printing support |
| Dimensions (L × W × H) | 35.5 × 38.5 × 19.5 cm |
| Weight | 7.5 kg |
| Lamp Lifetime | >5 years (3-year limited warranty) |
| Power Supply | Auto-ranging AC/DC adapter (100–240 V, 50/60 Hz) |
| Scan Speed | Slow / Medium / Fast — up to 1600 nm/min |
| Compliance | Designed and validated per ISO 9001 manufacturing standards |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin Category | Domestically Manufactured |
| Model | GENESYS™ 40/50 Vis/UV-Vis Spectrophotometer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 7000 Plus |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detector | Solid-State CCD Array |
| RF Generator | 27.12 MHz Solid-State |
| Plasma Viewing | Radial and Optional Axial |
| Cooling | Air-Cooled Torch |
| Sample Introduction | Integrated Peristaltic Pump with Autosampler Compatibility |
| Software Platform | Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) |
| Compliance | Designed to Support GLP/GMP, ISO/IEC 17025, and USP <730> workflows |
| Regulatory Readiness | Audit-trail enabled, electronic signature support per FDA 21 CFR Part 11 |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | iCAP 7000 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Price Range | USD 135,000 – 162,000 (estimated FOB UK) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | iCAP PRO |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | Not Specified |
| Precision (RSD) | Not Specified |
| Stability | Not Specified |
| Wavelength Range | Not Specified |
| Optical Resolution | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Produced |
| Model | iCAP PRO Series ICP-OES |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured under Thermo Fisher technology transfer and quality control) |
| Model | iCAP™ PRO ICP-OES |
| Wavelength Range | 167 nm to 852 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | MarqMetrix All-In-One Process Raman Analyzer |
| Instrument Type | In-line Raman Spectrometer |
| Spectral Range | 100 to 3250 cm⁻¹ |
| Spectral Resolution | 6.5 cm⁻¹ (average across spectral range) |
| Laser Excitation Wavelength | 785 nm |
| Laser Power | 10–450 mW (adjustable) |
| Detector | Thermally Stabilized CCD with Two-Stage TEC Cooling |
| Optical Interface | FC/PC Connectors (Excitation & Collection) |
| Dimensions (W × H × D) | 25 cm × 7.7 cm × 25 cm |
| Operating Temperature | 15–33 °C |
| Safety Certification | FDA-Reported Class 3B Laser Device |
| Compliance | Designed for cGMP and 21 CFR Part 11 readiness |
| Software Platform | Integrated Windows 10 PC running MarqMetrix Raman Suite Controller and optional Thermo Scientific Lykos PAT Software |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | microPHAZIR GP |
| Principle | Portable, Non-Destructive NIR Spectroscopy |
| Weight | 1.3 kg |
| Spectral Range | 1600–2400 nm |
| Measurement Time | ≤3 s (configurable) |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory |
| Data Transfer | USB (text-based .csv/.txt) |
| Operating Temperature | 5–40 °C |
| Battery | Rechargeable Li-ion with Hot-Swap Capability |
| Enclosure | Dust- and Splash-Resistant High-Impact Polymer Housing |
| Security | Multi-Level Password Protection |
| Standard Accessories | Rugged Waterproof Carry Case, Li-ion Battery Pack, 110/220 VAC Charger, Lanyard |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | microPHAZIR PC Carpet |
| Principle | Portable, On-Site NIR Spectroscopy |
| Weight | 1.25 kg |
| Measurement Time | 1.5 s |
| Light Source | Tungsten-Halogen Lamp |
| Display | Color LCD |
| Data Interface | USB to PC |
| Battery | Rechargeable Li-ion (≥5 h runtime, <2 h recharge time, dual-battery configuration) |
| Enclosure | Dust- and Splash-Resistant Engineering Plastic |
| Preloaded Library | Carpet Fiber Identification Database |
| Security | Multi-Level Password Protection |
| Calibration | Factory-Calibrated, Ready-to-Use Out-of-Box |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR PC Plastics |
| Principle | Portable, On-Site NIR Spectroscopy |
| Spectral Range | 1600–2400 nm (6250–4100 cm⁻¹) |
| Measurement Time | <3 s |
| Sampling Mode | Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | High-Strength Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory with USB Export |
| Interface | USB |
| Operating Temperature | 5–50 °C (non-condensing) |
| Power Supply | Dual Swappable Li-ion Batteries (4.5 h runtime), AC Adapter & Charger Included |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR™ Rx |
| Instrument Category | Portable NIR Spectrometer |
| Principle | Portable, non-destructive near-infrared reflectance spectroscopy |
| Wavelength Range | 1600–2400 nm |
| Scan Rate | 2 spectra per second |
| Data Acquisition Interval | 0.5 s (2 Hz) |
| Measurement Mode | Contact-based diffuse reflectance NIR analysis |
| Chemometrics Software | Method Generator™ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | NanoDrop 2000/2000c |
| Optical Design | Dual-Beam |
| Sample Volume | 0.5–2.0 µL |
| Measurement Time | <5 s (NanoDrop 2000), <3 s (NanoDrop 2000c cuvette mode) |
| Cuvette Temperature Control | 37 °C ±0.5 °C |
| Cuvette Stirring Speed | 150–850 rpm |
| Cuvette Dimensions | 12.5 mm × 12.5 mm × up to 48 mm |
| Pathlength Options | 10, 5, 2, and 1 mm |
| Absorbance Range (Cuvette Mode) | 0.008–1.5 AU |
| Base Unit Weight | 2.1 kg |
| Compliance | CE, FCC, RoHS |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | NanoDrop 3300 |
| Excitation Source | Filter-based LED array |
| Excitation Wavelength Range | 400–750 nm |
| Spectral Resolution | <3 nm FWHM (at Hg 546.1 nm) |
| Wavelength Accuracy | ±1 nm |
| Detection Mode | Full-spectrum fluorescence emission (400–750 nm) |
| Sample Volume | As low as 1 µL |
| Power Supply | USB-powered (no external power adapter required) |
| Cuvette-Free Operation | Yes |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic |
| Model | NanoDrop Lite Plus Ultra Micro Spectrophotometer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | NanoDrop Ultra Ultra-Micro Spectrophotometer and Fluorometer |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | NanoDrop™ One/OneC |
| Optical Design | Dual-beam |
| Detector | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–850 nm |
| Wavelength Automation | Fully Automatic |
| Spectral Bandwidth | ≤1.8 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.01% T |