| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Nicolet iS5 |
| Price Range | USD 52,000–65,000 (FOB) |
| Instrument Type | Fourier Transform |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nicolet iS50 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Wavenumber Range | 27,000–15 cm⁻¹ |
| Spectral Resolution | Better than 0.09 cm⁻¹ |
| Scan Speed | 0.158 cm/s (slow), 6.28 cm/s (fast) |
| Signal-to-Noise Ratio | >55,000:1 (1-minute acquisition) |
| Brand | Thermo Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Thermo Scientific Nicolet iS50 FTIR Spectrometer |
| Instrument Category | Infrared Auxiliary Equipment |
| Instrument Form Factor | Benchtop (not portable — correction per technical specification) |
| Spectral Resolution | 0.09 cm⁻¹ |
| Light Sources | Dual-source configuration (Polaris long-life IR source + tungsten-halogen visible/NIR source) |
| Detectors | Triple-detector sample compartment (MCT, DTGS, and optional far-IR detector) |
| Optical Path | Gold-coated optics (standard), aluminum-coated option available |
| Beam Delivery | Parallel or focused output ports |
| Standard Features | Motorized calibration wheel, motorized neutral density filter wheel, motorized polarizer wheel (optional), purge interface (optional), USB 2.0 high-speed interface, integrated diamond ATR (mid- and far-IR capable), Smart accessory compatibility, automatic beam alignment, internal storage for two additional beamsplitters |
| Software Platform | OMNIC Specta with Mercury GC, TGA-IR, and step-scan modules |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet™ iS50 FTIR |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Instrument Category | Fourier Transform Infrared Spectrometer |
| Dimensions (Base Only) | 62.6 × 69.8 × 27.6 cm |
| Weight (Base Only) | 60 kg |
| Dimensions (with ABX) | 62.6 × 69.8 × 50.8 cm |
| Weight (with ABX) | 64 kg |
| Optical Path | Fully Gold-Coated Optics (Aluminum Coating Optional) |
| Light Sources | Dual-source Configuration (Polaris™ Long-Life IR Source + Tungsten-Halogen Visible/NIR Source) |
| Detectors | Three Detector Ports in Main Sample Compartment |
| Standard Features | Automated Attenuator Wheel, Smart Accessories Compatibility, Built-in Calibration Wheel, Parallel & Focused Beam Output Ports |
| Optional Modules | Integrated Mid- and Far-IR Diamond ATR, Automatic Beamsplitter Exchange (ABX), Raman Module, NIR Module with Integrating Sphere & Fiber Optics, TGA-IR Interface, GC-IR Interface |
| Software Platform | OMNIC Spectroscopy Suite with OMNIC Anywhere Cloud Integration |
| Data Security | AWS-Hosted Thermo Fisher Connect Platform |
| Compliance | Supports 21 CFR Part 11–compliant audit trails (via OMNIC Enterprise), GLP/GMP-ready workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory FT-IR Spectrometer |
| Model | Summit |
| Instrument Type | Benchtop FT-IR |
| Wavenumber Range | 8,000–350 cm⁻¹ |
| Spectral Resolution | < 0.6 cm⁻¹ (optimizable to 0.4 cm⁻¹) |
| Signal-to-Noise Ratio | 45,000:1 (standard), up to 48,000:1 (optional) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ at 2,000 cm⁻¹ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Manufactured |
| Model | Nicolet Summit X FTIR Spectrometer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Niton Apollo LIBS |
| Instrument Category | Handheld |
| Integration | All-in-One |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Niton Apollo LIBS |
| Instrument Type | Handheld |
| Integration | Integrated |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Orion AquaMate 7100 |
| Optical Design | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 5.0 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Wavelength Scanning | Automatic |
| Display | 7-inch High-Resolution Touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Orion AquaMate 8100 |
| Optical Design | Double-Beam |
| Detector | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 2.0 nm |
| Stray Light | <1.0%T @ 198 nm (KCl), <0.05%T @ 220 nm (NaI), <0.03%T @ 340 nm (NaNO₂) |
| Automation Level | Automatic Wavelength Selection |
| Display | 7-inch High-Resolution Touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | SPECTRONIC 200E |
| Instrument Architecture | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 340–1000 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | <4 nm |
| Wavelength Accuracy | ±1.0 nm (typical, per ASTM E275 and ISO 6223) |
| Stray Light | <0.1% T at 340 nm (measured at NaNO₂ peak) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | TruDefender FTX |
| Instrument Type | Handheld |
| Instrument Principle | Fourier Transform Infrared Spectroscopy |
| Spectral Range | 4000–650 cm⁻¹ |
| Optical Interface | Diamond Crystal ATR |
| IP Rating | IP67 |
| Operating Temperature | −20 °C to +40 °C |
| Dimensions (L×W×H) | 22.61 × 11.42 × 5.33 cm |
| Weight | 1.41 kg |
| Battery | Removable & rechargeable Li-ion or dual 123A (e.g., SureFire) |
| Compliance | MIL-STD-810G tested, IP67 certified |
| Languages | English, Chinese, German, Russian (selectable) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruScan |
| Instrument Category | Portable/Handheld Raman Spectrometer |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | TruScan RM, microPHAZIR RX |
| Principle | Portable, Non-Destructive, In-Situ Spectroscopic Identification |
| Regulatory Compliance | 21 CFR Part 11, USP <1119>, EP 2.2.48, ASTM E1840, ISO/IEC 17025 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | Thermo Scientific™ NanoDrop™ Ultra |
| Pricing | Upon Request |
| Brand | Thorlabs |
|---|---|
| Origin | USA |
| Model | OSA203 |
| Wavelength Range | 1000–2500 nm |
| Spectral Resolution | 60 pm @ 1550 nm (0.25 cm⁻¹, broadband mode) |
| Wavelength Meter Resolution | 0.2 pm |
| Spectral Accuracy | ±4 pm (broadband), ±2 pm (wavelength meter mode) |
| Spectral Precision | ±1 pm (broadband), 0.2 pm (wavelength meter mode) |
| Input Power Max | 10 mW (CW), 20 mW (peak) |
| Detector | InGaAs |
| Input Fiber | SMF or step-index MMF ≤ Ø50 µm, NA < 0.22 |
| Dimensions | 320 × 149 × 475 mm |
| Input Voltage | 100–240 VAC, 47–63 Hz, 250 W max |
| Operating Temp | 10–40 °C |
| Relative Humidity | <80% non-condensing |
| Interface | High-speed USB 2.0 (6 MB/s transfer via ping-pong buffering) |
| Reference Laser | Stabilized HeNe (λ₀ = 632.9913 nm vacuum), temperature/pressure-compensated using Edlén equation |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Tianyan Instrument Co., Ltd. |
| Model | TY-FP640 |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Detection Principle | Flame Emission Spectroscopy (FES) |
| Detector | Silicon Photocell |
| Wavelength Selection | Interference Filter |
| Display | 3-digit LED |
| Stability (15 s) | ≤ 3% RSD |
| Stability (6 min, 6 readings) | ≤ 15% RSD |
| Linearity Error | K ≤ 0.005 mmol/L |
| Sample Aspiration Rate | < 6 mL/min |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤ 85% RH |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, Grounded |
| Rated Power | 250 W |
| Dimensions (W×D×H) | 400 × 250 × 500 mm |
| Weight | 12.5 kg |
| Standard Configuration | Main unit, air compressor, accessories & spare parts |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | TR-PLIF |
| Laser Repetition Rate | ≥1 kHz |
| Excitation Source | Frequency-Doubled Nd:YAG (532 nm), Pumped by High-Repetition-Rate YAG Laser |
| Detection | Intensified CCD or sCMOS Camera with Sub-Microsecond Gating |
| Temporal Resolution | <100 ns (adjustable via optical delay and camera gating) |
| Spatial Resolution | ≤50 µm (system-limited, dependent on optics and pixel binning) |
| Spectral Bandwidth | Tunable via narrowband interference filters (FWHM ≈ 1–5 nm) |
| Compliance | CE Marked, RoHS Compliant |
| Brand | TIME-TECH SPECTRA |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Femtosecond Pump-Probe Spectroscopy System |
| Model | Femto-TA100 Series |
| Spectral Range | 320–1650 nm (configurable sub-ranges: UV-Vis 320–1000 nm, NIR 900–1650 nm) |
| Spectral Resolution | 1024-pixel CCD array detector |
| Temporal Resolution | ≤8 ns (extendable to millisecond range via delay line reconfiguration) |
| Data Acquisition Rate | Up to 8 kHz full-spectrum acquisition |
| Optical Delay Line Speed | 400 mm/s, positional accuracy ±0.1 µm |
| Instrument Response Function (IRF) | ≤1.5 × laser pulse duration |
| Pre-zero Signal-to-Noise Ratio | ≤0.1 mOD |
| Brand | Timegate |
|---|---|
| Origin | Finland |
| Model | Pico Raman |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | –200 to 2000 cm⁻¹ |
| Spectral Resolution | 5 cm⁻¹ |
| Spatial Resolution | 2 µm |
| Minimum Wavenumber | –200 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFS-10B |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | AFS-10B |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Pneumatic Control | Valve Island System |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control | Yes |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AFS-10B |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Mode | Peristaltic Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Pneumatic Control System | Valve Island |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Adjustable (Precise Thermal Stabilization) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AFS-10F |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Linear Dynamic Range | >3 orders of magnitude |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Adjustable (Precise PID-controlled heating) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | AFS-10U |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Peristaltic Pump |
| Waste Disposal | Rear Exhaust Design |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control | Yes |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Method | Peristaltic Pump |
| Waste Disposal | Rear Exhaust Configuration |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | < 0.6% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| PMT Wavelength Range | 160–320 nm |
| Atomizer Temperature Control | Precise PID-regulated heating |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AFS-11B |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear Exhaust Design |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Valve Island System |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |
| Photomultiplier Tube Wavelength Range | 160–320 nm |
| Atomizer Temperature Control Range | Programmable |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFS-11C |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Rear-mounted Waste Drainage |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Valve Island System |
| Detectable Elements | As, Sb, Bi, Sn, Se, Te, Pb, Ge, Hg, Cd, Zn |
| Relative Standard Deviation (RSD) | <0.6% |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As, Sb, Se, Bi, Te, Hg, Sn, Pb < 0.01 µg/L |