| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | DXR3 Smart |
| Instrument Category | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–3500 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Evolution 200 Series |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Selection |
| Spectral Bandwidth | Variable at 1 nm or 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | Evolution 260 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.8 nm |
| Spectral Bandwidth | 1.0 nm and 2.0 nm |
| Stray Light | ≤1% T |
| Automation | Motorized Wavelength Selection |
| Light Source | Xenon Flash Lamp |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Evolution 350 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 0.5, 1.0, 1.5, 2.0, 4.0 nm |
| Wavelength Accuracy | ±0.3 nm (190–900 nm) |
| Stray Light | <0.02% T at 220 nm (NaI), <0.02% T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Evolution™ One/One Plus UV-Vis Spectrophotometer (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | Fixed 1.0 nm (standard), variable options available on One Plus |
| Optical Design | Double-beam with Czerny-Turner monochromator |
| Light Source | Xenon flash lamp |
| Detector | Dual silicon photodiode array |
| Baseline Flatness | ±0.001 A (200–800 nm, 1.0 nm SBW, smoothed) |
| Photometric Accuracy | ±0.010 A @ 60 mg/L K₂Cr₂O₇ |
| Stray Light | ≤1% T @ 198 nm (KCl) |
| Wavelength Accuracy | ±0.5 nm (@ Hg lines 541.9/546.1 nm), ±0.8 nm (full range) |
| Wavelength Repeatability | ≤0.05 nm (SD, 10 measurements @ 546.1 nm Hg line) |
| Photometric Precision | ±0.004 A @ 1 A, ±0.008 A @ 2 A (NIST-traceable neutral density filters, 440 nm) |
| Noise Level | ≤0.00015 A RMS @ 0 A |
| Drift | <0.0005 A/h @ 500 nm (1.0 nm SBW, 1 h warm-up) |
| Scan Speed | 1–6000 nm/min (variable) |
| Data Interval | 0.1–10 nm selectable |
| Photometric Display Range | –0.3 to 4.0 A |
| Absorbance Linearity | >3.5 A |
| Dimensions (L×W×H) | 593 × 475 × 266 mm |
| Weight | 14.5 kg (32 lb) |
| Power Requirement | 100–240 V AC, auto-switching, 50/60 Hz, max. 150 W |
| Lamp Lifetime | >5 years (typical usage, no real-time signal monitoring) |
| Compliance | USP <857>, EP 2.2.25, ISO/IEC 17025, ASTM E275, FDA 21 CFR Part 11 (with Insight Pro Security Pack) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FirstDefender RM |
| Instrument Category | Portable/Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.5 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FirstDefender RMX |
| Instrument Category | Portable/Handheld Raman Spectrometer |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.5 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Handheld Dual-Mode Spectrometer (Raman + FTIR) |
| Model | Gemini |
| Spectral Range (Raman) | 250–2875 cm⁻¹ |
| Spectral Resolution (Raman) | 7–10.5 cm⁻¹ (FWHM, full range) |
| Spectral Resolution (FTIR) | 4 cm⁻¹ |
| Minimum Wavenumber (Raman) | 250 cm⁻¹ |
| Minimum Wavenumber (FTIR) | 650 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans of identical sample under fixed acquisition conditions |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Thermo Scientific Gemini Handheld Raman-FTIR Dual-Mode Spectrometer |
| Instrument Type | Portable/Handheld Raman-FTIR Spectrometer |
| Spectral Range | FTIR: 4,000–650 cm⁻¹ |
| Raman | 250–2,875 cm⁻¹ |
| Certifications | MIL-STD-810G, IP67 |
| Dimensions (L×W×H) | 25.6 × 14.6 × 6.1 cm |
| Weight | 1.9 kg |
| Operating Temperature | −20 °C to +50 °C |
| Power | Integrated 3.7 V Li-polymer battery (1 unit) + three CR123A batteries |
| Data Export Formats | SPC, TXT, JPEG |
| Optical Configurations | FTIR – Single-reflection diamond ATR crystal |
| Software Integration | Compatible with HazMasterG3™ decision support system |
| Support | 5-year comprehensive technical support, 24/7 spectral interpretation assistance by PhD-level spectroscopists |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Genesys 10s |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Speed | Up to 4200 nm/min |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Light Source | Pulsed Xenon Flash Lamp (3-year warranty) |
| Grating | Holographic Master Grating |
| Cuvette Changer | Integrated 6-position Auto-Changer |
| Data Storage | USB flash drive support |
| Compliance | Designed to support USP <85>, EP 2.2.25, and JP 17 UV-Vis validation protocols |
| Software Options | GENESYS Instrument Control Software (PC-based), optional FDA 21 CFR Part 11-compliant audit trail module |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | GENESYS 150 |
| Optical Design | Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Produced |
| Model | GENESYS™ 30 Visible Spectrophotometer (Domestically Manufactured) |
| Pricing | Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | iCAP PRO ICP-OES |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Spectral Resolution | 7 pm at 200 nm |
| Wavelength Range | 167.021–852.145 nm |
| RF Generator | 27.12 MHz, 750–1600 W adjustable |
| Plasma Gas Flow | 0.0–20.0 L/min (MFC-controlled) |
| Nebulizer Gas Flow | 0.0–1.5 L/min (MFC-controlled) |
| Auxiliary Gas Flow | 0.0–2.0 L/min (MFC-controlled) |
| Radial Viewing Height | 6–18 mm |
| Torch Orientation | Vertical |
| Detector | Charge Injection Device (CID) Array |
| Purge Gas | Optional integrated MFC (0–0.25 L/min) |
| Sample Introduction | 4-channel peristaltic pump (0–125 rpm) |
| Warm-up Time | ≤5 min from standby |
| UV Enhancement Mode | Dual UV exposure for improved sensitivity below 240 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Wavelength Range | 190–900 nm |
| Focal Length | 270 mm |
| Slit Widths | 0.2, 0.5, 1.0, 2.0 nm (motorized) |
| Lamp Holder | 6-position, fully automated, independent lamp power supplies |
| Burner Head | Titanium alloy, finned design, optional 50 mm or 100 mm length |
| Nebulizer Chamber | Inert PTFE-nozzle & Pt/Ir capillary |
| Gas Control | Binary-valve digital pneumatic system for air/acetylene and N₂O/acetylene |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | iCE 3300 |
| Instrument Type | Flame AAS |
| Monochromator | Echelle grating |
| Optical System | Dual-beam |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Deuterium lamp (D₂) |
| Resolution | 0.3 nm |
| Sensitivity | 0.3 µg/mL for Cu (at 324.8 nm, 1% absorption) |
| Repeatability (RSD) | ≤0.3% |
| Detection Limit | 0.006 µg/mL for Cu |
| Baseline Stability | ±0.005 absorbance units/30 min |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | iCE 3400 |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Zeeman Electro-Magnetic Field Correction |
| Brand | Thermo Fisher |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | iCE 3500 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal (Auto-Absorption) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iS10 |
| Instrument Type | Fourier Transform |
| Optical Design | Sealed, Desiccated Interferometer with Dynamic Alignment |
| Detector | DTGS (Deuterated Triglycine Sulfate) |
| Scan Speed | Up to 5 scans/sec (standard mode) |
| Spectral Resolution | Adjustable down to 0.4 cm⁻¹ |
| Wavelength Range | 4000–400 cm⁻¹ |
| Beam Splitter | KBr |
| Compliance | ASTM E1421, ISO 18382, USP <1119>, GLP/GMP-ready data integrity architecture |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Lumina |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth (Slit) | 0.5 nm |
| Resolution | 0.5 nm |
| Sensitivity | >4000:1 (at water Raman peak) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Source | 150 W Xenon Arc Lamp |
| Optical Design | Horizontal Beam Path |
| Monochromator Type | Grating-based, Pre-aligned Modular Monochromator |
| Detector | High-sensitivity PMT with extended red response |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific MarqMetrix All-in-One Online Raman Spectrometer |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 100–3,250 cm⁻¹ |
| Spectral Resolution | 6.5 cm⁻¹ (average across full spectrum) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NanoDrop Eight Ultra Micro Spectrophotometer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NanoDrop Lite Plus |
| Instrument Architecture | Dual-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 260–280 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 0.5 nm |
| Stray Light | 0.01% T |
| Key Applications | Nucleic Acid & Protein Quantification, Purity Ratio Analysis (A260/A280, A260/A230) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoDrop™ One |
| Price | USD 16,500 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet 6700 |
| Price Range | USD 32,000 – 38,500 (FOB) |
| Instrument Type | FT-IR |
| Configuration | Benchtop Laboratory System |
| Wavenumber Range | 7800 – 350 cm⁻¹ |
| Spectral Resolution | < 0.09 cm⁻¹ |
| Scan Speed | 130,000 scans per second (DSP-controlled interferometer) |
| Signal-to-Noise Ratio | 50,000:1 (peak-to-peak, 4 cm⁻¹, 1 min scan, KBr beam splitter, DTGS detector) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Nicolet Apex FTIR Spectrometer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | Nicolet Apex FTIR Spectrometer |
| Pricing | Request Quote |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific Nicolet Series |
| Instrument Type | Laboratory-Based |
| Spectrometer Type | Fourier Transform (FT-IR & FT-Raman) |
| Application Domain | Molecular Spectroscopy & Surface Analysis |
| Compliance Framework | ASTM E1421, ISO 17025, USP <1119>, FDA 21 CFR Part 11 (Software Validation Ready), GLP/GMP-Ready Data Integrity Architecture |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet FT-SPR |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet iS10 |
| Instrument Type | Fourier Transform |
| Compliance Standards | ASTM E1421, NIST-traceable, USP <1119>, EP 2.2.24, JP 2.07, FDA 21 CFR Part 11 (with ValPro™ and OMNIC Security Suite) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet iS10 |
| Instrument Type | Fourier Transform Infrared (FT-IR) |