| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | 1200:1 (RMS), 15,000:1 (RMS with Background Subtraction) |
| Wavelength Accuracy | ±2 nm |
| Excitation Source | Pulsed Xenon Arc Lamp |
| PMT Detection Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Software | FL Analyst (English & Chinese GUI) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 1.0–20 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | >450:1 (Peak-to-Peak) |
| Wavelength Accuracy | ±2.0 nm |
| Excitation Source | Xenon Arc Lamp |
| Standard PMT Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Spectral Correction | Full-mode (Excitation/Emission/Spectral Response) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Structure | Single-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.05% T |
| Automation Level | Automatic Wavelength Scanning |
| Display | 5-inch TFT Color Touchscreen |
| Optical Platform | Integrated Die-Cast Optical Base |
| Compliance | Designed for GLP-compliant routine analysis |
| Connectivity | USB and RS-232 interfaces for PC control and printer output |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | UV1101II: 1 nm |
| UV1102II | 2 nm |
| UV1100II | 4 nm |
| Stray Light | ≤0.05% (at 220 nm using NaI |
| Compliance | CE, IEC 61010-1, IEC 61326-1 (EMC), LVD Directive |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV1200 |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.3 nm |
| Stray Light | ≤0.05% |
| Display | 7-inch HD capacitive touchscreen |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UV2500 |
| Price Range | USD 9,800–13,900 (FOB Shanghai) |
| Optical Design | Dual-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scan |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | ≤0.05% T at 220 nm and 340 nm |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | UV2600 |
| Price Range | USD 9,800–13,900 (FOB Shanghai) |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Scanning | Motorized, Software-Controlled |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, 5 nm (Auto-Selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | <0.010% T (at 220 nm, NaI |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Model | UV2600 |
| Optical System | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.5, 1, 2, 5 nm (automatically selectable) |
| Stray Light | <0.010% T (at 220 nm with NaI |
| Software | UV Analyst (Windows 2000/XP/Vista compatible) |
| Sample Volume Minimum | 50 µL |
| Compliance | GLP/GMP-supporting diagnostics, self-validation routines |
| Brand | TechnoSpex |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Microfluidic Integration | Yes |
| Modular Microscope Compatibility | Zeiss, Leica, Olympus, Nikon |
| Minimum Spot Size | ≤1 µm (with 100× objective) |
| Real-Time Spectral Acquisition | Supported |
| Detection Modes | Raman, Transmittance, Absorbance, UV-Vis Absorption, Fluorescence Excitation, XY Stage Mapping |
| Customization | Fully Configurable per Application Requirement |
| Key Specifications | Available upon technical consultation |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy DC Arc |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Repeatability | ≤1.5% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm (at 200 nm) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Precision (RSD) | ≤1.5% |
| Stability (Drift) | ≤2% |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy Plus |
| Instrument Type | Full-Spectrum Direct-Reading ICP Optical Emission Spectrometer |
| Detection Limit (Zn @ 213.856 nm) | < 0.1 µg/L |
| Precision (RSD) | ≤ 0.5% |
| Long-Term Stability (RSD, 4h) | ≤ 1.0% |
| Wavelength Range | 130–1100 nm |
| Optical Resolution | 0.005 nm @ 200 nm |
| Detector | Custom 28 × 28 mm CMOS sensor with 3.38 million effective pixels |
| Readout Speed | >10× faster than conventional CID/CCD detectors |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy7 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit (Zn at 213.856 nm) | <0.1 µg/L |
| Precision (RSD) | ≤1.0% |
| Stability (RSD over 4 hours) | ≤1.0% |
| Wavelength Range | 165–1100 nm |
| Optical Resolution | ≤0.007 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Detection Limit (Ca at 396.847 nm) | 0.155 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (2-hr drift) | ≤1.0% |
| Optical Resolution | 0.005 nm |
| RF Generator Cooling | Air-Cooled |
| Plasma Torch Assembly | Ceramic RF Load Coil |
| Optical System | Echelle Grating with ICCD Detector |
| Compliance | ASTM D1976, ISO 11885, USP <233>, EPA Methods 200.7 & 6010E |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | HRS-300, HRS-500 |
| Focal Length | 300 mm (HRS-300), 500 mm (HRS-500) |
| f-number | f/3.9 (HRS-300), f/6.5 (HRS-500) |
| Linear Dispersion | 2.38 nm/mm (HRS-300), 1.52 nm/mm (HRS-500) |
| PMT Resolution (1200 g/mm grating, 435.8 nm, 10 µm slit) | 0.09 nm (HRS-300), 0.05 nm (HRS-500) |
| CCD Resolution (1200 g/mm grating, 435.8 nm, 20 µm pixel & slit) | 0.10 nm (HRS-300), 0.07 nm (HRS-500) |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Integrated Online LIBS System |
| Price Range | USD 210,000 – 280,000 |
| Instrument Type | Online |
| Integration Level | Fully Integrated |
| Core Components | Q-switched Nd:YAG Laser Source, Echelle or Czerny–Turner Spectrometer, ICCD Detector, Synchronization Controller, LIBS-Specific Acquisition & Analysis Software |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OLED/QLED Device Lifetime Testing System |
| Price Range | USD 14,000 – 28,000 |
| Channel Capacity | 32 / 64 / 128 (scalable to 512 channels) |
| Operating Modes | Constant Current, Constant Voltage, Constant Luminance (user-selectable) |
| Current Output Range | 0.03 µA – 100 mA (accuracy ±1% of reading) |
| Voltage Output Range | 1.0 – 20 V (accuracy <±1%) |
| Device Architecture Support | Bottom-emission, top-emission, inverted, and standard stack configurations (customizable per device architecture) |
| Substrate Compatibility | Standard 5 cm × 5 cm |
| Temperature Range | RT+10°C to 100°C (standard) |
| Environmental Options | Inert atmosphere testing (N₂/Ar), glovebox-integrated operation, UPS-backed power supply |
| Software Platform | LabVIEW-based control and data acquisition with real-time logging, timestamped event tracking, and export-ready CSV/Excel output |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RTS-B |
| Price | USD 70,000 (approx.) |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 60–5000 cm⁻¹ |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Excitation Lasers | Standard 532 nm |
| Microscope | Olympus BX53 or Leica DM2700 upright research-grade microscope |
| Gratings | 150, 600, 1800 grooves/mm (blaze wavelength selectable) |
| Detector | Deep-cooled, infrared-enhanced, low-noise scientific CCD |
| Confocal Mode | Slit-CCD coupled high-throughput confocal architecture |
| Optical Path | Horizontal, rigid monolithic design |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-EX |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–1100 nm |
| Spectral Resolution | <0.8 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-HiR |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–1100 nm |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-mini |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 300–1100 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TES-300 |
| Optical Design | Single-Beam |
| Detector | CCD Array |
| Wavelength Range | 104–1040 nm |
| Wavelength Selection | Manual Drive |
| Spectral Bandwidth | 10 nm |
| Wavelength Accuracy | ±0.01 nm |
| Stray Light | < 0.01% T |
| Grating | 1200 l/mm, Al/MgF₂ coated (optimized 100–300 nm), user-replaceable |
| Input Focal Length | 200 mm |
| Output Focal Length | 187.9 mm |
| F/# | 4.2 |
| Deviation Angle | 64° |
| Optimal Operational Range | 115–300 nm |
| Full Usable Range | 25–1000 nm (gold coating recommended below 100 nm) |
| Slit | Adjustable entrance and exit slits on dual-arm configuration |
| Grating Drive | Encoded Angular Encoder Grating Drive (AEGD) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Antaris II |
| Instrument Type | Laboratory |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–12000 cm⁻¹ |
| Scan Speed | 5 scans/sec |
| Data Sampling Interval | 2 cm⁻¹ |
| Measurement Modes | Transmission, Diffuse Reflectance, Transflectance, Transdiffuse |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Antaris MX |
| Instrument Type | Online/At-line Portable FT-NIR Analyzer |
| Principle | Fourier Transform Near-Infrared Spectroscopy (FT-NIR) with Real-time Process Integration |
| Wavelength Range | 4000–12000 cm⁻¹ |
| Scan Speed | 5 scans per second |
| Spectral Resolution | 2 cm⁻¹ (data sampling interval) |
| Measurement Modes | Transmission, Transflection, Diffuse Reflectance |
| Chemometrics Software | TQ Analyst v9+ and RESULT v3.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Antaris Target In-Process Mixing Monitor |
| Instrument Category | Online Near-Infrared Spectrometer |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 5300–7500 cm⁻¹ |
| Scan Speed | 12.5 scans/second |
| Spectral Sampling Interval | 0.7 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ARL 3460 |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Line Density | 3600 lines/mm |
| Wavelength Range | 120–850 nm |
| Number of Channels | 60 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ARL 3460 |
| Condition | Refurbished & Fully Qualified |
| Compliance | Meets ASTM E1184, ISO 11577, and EN 10052 for metallic alloy analysis |
| Software | ARL SpectraGraph v8.x (with full calibration history and audit trail) |
| Detector Type | Photomultiplier Tube (PMT) array |
| Excitation Source | High-energy spark discharge (400–1000 V, adjustable frequency) |
| Typical Analysis Time | 20–45 s per sample |
| Wavelength Range | 120–800 nm |
| Resolution | ≤ 0.01 nm at 200 nm |
| Sample Form | Solid metal discs or pins (Ø 25–40 mm, thickness ≥ 5 mm) |
| Gas Requirement | Argon purge (99.995% purity, flow rate 3–5 L/min) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biomate 160 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioMate 160 |
| Instrument Architecture | Pseudo-Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Automated |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | DXR3xi |
| Instrument Category | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Excitation Wavelength | 455 nm (optional lasers available) |
| Spectral Reproducibility | ±0.1 cm⁻¹ |