Spectroscopy Instruments
Filter
Showing 2101–2130 of 2617 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NanoDrop™ One/OneC |
| Price | Upon Request |
| Certifications | CE, UL/CSA |
| Connectivity | 3× USB-A, Ethernet, Bluetooth™, Wi-Fi (OneC only) |
| Detector | 2048-pixel CMOS linear image sensor |
| Display | 7″ HD color touchscreen (1280 × 800 px) |
| Light Source | Xenon flash lamp |
| Spectral Bandwidth | ≤1.8 nm FWHM (at Hg 254 nm) |
| Wavelength Range | 190–850 nm |
| Optical Path | Auto-adjusting from 0.030 to 1.0 mm |
| Absorbance Accuracy | ±3% at 0.97 A, 302 nm (25°C, Abs/mm) |
| Absorbance Range (10-mm equivalent) | 0–550 A (microvolume base), 0–1.5 A (cuvette) |
| Measurement Time | 8 seconds |
| Repeatability | ±0.002 A or 1% CV (whichever is greater |
| Sample Temperature Control | 37°C (cuvette mode only) |
| Power Consumption | 12–18 W (operational), 5 W (standby) |
| Weight | 3.6 kg (7.9 lb) |
| Dimensions (L×W×H) | 20 × 25.4 × 32.3 cm (8 × 10 × 12.7 in.) |
| Supported Languages | English, French, German, Spanish, Polish, Chinese, Japanese, Korean |
| Compatible Peripherals | DYMO LabelWriter 450 printer, Bluetooth keyboard/mouse, barcode scanner |
| Applications | Nucleic acid quantification (A260, A260/A280, A260/A230), labeled nucleic acids, protein A280/A205, Pierce 660, Bradford, BCA, Lowry assays, OD600, kinetic studies, custom UV-Vis methods |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Nicolet iS10 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | Better than 0.4 cm⁻¹ |
| Scan Speed | 40 spectra/sec |
| Signal-to-Noise Ratio | >50,000:1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet Summit |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Wavenumber Range | 8000–350 cm⁻¹ |
| Resolution | 0.5 cm⁻¹ |
| Scan Speed | 130,000 scans/sec |
| Signal-to-Noise Ratio | 40,000:1 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dispersive Raman Spectrometer (not FT-Raman) |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | Micron-level |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Evolution One Plus |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 nm to 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.0 nm (fixed) |
| Wavelength Accuracy | ±0.5 nm (at Hg lines 541.9 nm and 546.1 nm), ±0.8 nm (full range 190–1100 nm) |
| Wavelength Repeatability | ≤0.05 nm (SD, n=10 at 546.1 nm Hg line) |
| Stray Light | <0.01% T (i.e., >2 A at specified wavelengths) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution One |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized Auto-Scanning |
| Spectral Bandwidth | 0.5–4 nm (selectable) |
| Wavelength Accuracy | ±0.5 nm (at Hg emission lines 541.9 nm and 546.1 nm), ±0.8 nm (full range) |
| Wavelength Repeatability | ≤0.05 nm (SD, 10 measurements at 546.1 nm Hg line) |
| Stray Light | <0.01% T (at 220 nm, NaI |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Double-beam UV-Vis spectrophotometer |
| Detector | Photodiode array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Repeatability | ≤0.05 nm (at 546.1 nm Hg line, SD of 10 measurements) |
| Spectral Bandwidth | Fixed 1.0 nm |
| Baseline Flatness | ±0.001 A (200–800 nm, 1.0 nm SBW, smoothed) |
| Photometric Accuracy | ±0.010 A (60 mg/L K₂Cr₂O₇) |
| Stray Light | ≤1% T @ 198 nm (KCl) |
| Wavelength Accuracy | ±0.5 nm (Hg lines at 541.9/546.1 nm), ±0.8 nm (full range) |
| Photometric Precision | ±0.004 A at 1 A, ±0.008 A at 2 A (NIST-traceable neutral density filters, 440 nm) |
| Noise Level | ≤0.00015 A (0 A), ≤0.00025 A (1 A), ≤0.00050 A (2 A, RMS, 260 nm, 1.0 nm SBW) |
| Drift | <0.0005 A/h (500 nm, 1.0 nm SBW, after 1 h warm-up) |
| Light Source | Xenon flash lamp |
| Dimensions (L×W×H) | 593 × 475 × 266 mm |
| Weight | 14.5 kg |
| Power Requirement | 100–240 V AC, auto-switching, 50/60 Hz, max. 150 W |
| Warranty | 2 years instrument, 3 years lamp |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Genesys 30 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05% at 340 nm and 700 nm |
| Absorbance Range | ±3.0 A |
| Light Source | Tungsten Halogen Lamp |
| Display | 5-inch Full-Color TFT LCD |
| Data Export | USB Mass Storage Mode (TXT format) |
| Software | Onboard VISIONlite UI |
| Warranty | 3 Years Limited |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | SPECTRONIC 200 |
| Instrument Architecture | Single-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 340 nm – 1000 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | < 4 nm |
| Wavelength Accuracy | ±2.0 nm |
| Stray Light | < 0.2 %T |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TruDefender FT |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared Spectroscopy |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 2 scans/sec |
| Weight | 1.3 kg |
| Dimensions | 19.6 × 11.2 × 5.3 cm |
| Optical Interface | Diamond ATR Crystal |
| Environmental Rating | MIL-STD-810F & IP67 |
| Battery Life | >4 hours (rechargeable Li-ion or CR123A primary cells) |
| Operating Temperature | −25 °C to +40 °C |
| Data Export Formats | SPC, TXT, JPEG |
| Compliance | ASTM E2534 (for field-deployable chemical ID), GLP/GMP-ready audit trail support in firmware |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruDefender FTX |
| Instrument Category | Fourier Transform Infrared (FTIR) |
| Form Factor | Portable |
| Wavenumber Range | 4,000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Signal-to-Noise Ratio | ≥1,000:1 (typical, 32 scans, ambient conditions) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TruNarc |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM, full spectral range) |
| Spatial Resolution | Not applicable (single-point probe geometry) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans of identical sample under stable conditions |
| Weight | 570 g |
| Dimensions | 16.2 cm × 10.4 cm × 5.1 cm |
| Onboard Database | >60 controlled substances and illicit drugs |
| Data Output Formats | CSV, Excel (.xlsx), SPC, PDF |
| Battery Life | Up to 10 hours (rechargeable 3.7 V Li-ion pack) |
| Power Options | DC wall adapter (5 V, 1.5 A), optional vehicle charger |
| Operating Temperature | −10 °C to +50 °C |
| Interface Language | English, Simplified Chinese |
| Connectivity | Micro-USB to host PC |
| Software | TruNarc Management Software (Windows-compatible) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruScan GP |
| Instrument Category | Portable/Handheld Raman Spectrometer |
| Spectral Range | 250–2875 cm⁻¹ |
| Spectral Resolution | 8–10.5 cm⁻¹ (FWHM, across full range) |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 8 cm⁻¹ |
| Spectral Repeatability | ≤0.1 cm⁻¹ |
| Excitation Wavelength | 785 nm ±0.5 nm |
| Laser Linewidth | ≤2 cm⁻¹ |
| Laser Power Output | 250 mW ±25 mW |
| Collection Optics NA | 0.33 |
| Working Distance | 18 mm |
| Spot Size | 0.2–2.5 mm |
| Exposure Time (Auto Mode) | as low as 12 ms |
| Power Supply | AC 100–240 V, 50/60 Hz via DC wall adapter |
| Weight | 0.9 kg (2 lb) |
| Dimensions | 20.8 × 10.7 × 4.3 cm (8.2 × 4.2 × 1.7 in) |
| Operating Temperature | –20 °C to +40 °C (continuous) |
| Barcode Support | Standard 1D & 2D symbologies |
| Regulatory Compliance | FDA 21 CFR Part 11, CE Marked |
| Accessories | Vial holder, universal tablet holder (optional) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruScan |
| Instrument Category | Portable/Handheld Raman Spectrometer |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruScan RM |
| Instrument Category | Portable/Handheld Raman Spectrometer |
| Spectral Range | 250–2875 cm⁻¹ |
| Spectral Resolution | 8–10.5 cm⁻¹ (FWHM, full spectral range) |
| Spatial Resolution | Not applicable (single-point probe |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans on homogeneous sample |
| Excitation Wavelength | 785 nm ± 0.5 nm |
| Laser Linewidth | 2 cm⁻¹ |
| Laser Power Stability | < 0.1 cm⁻¹ drift over 8 hours |
| Output Power | 250 mW ± 25 mW |
| Numerical Aperture | NA = 0.33 |
| Working Distance | 18 mm |
| Exposure Time | Auto mode (minimum 12 ms) |
| Battery | Rechargeable Li-ion, >4 h continuous operation |
| Dimensions | 20.8 × 10.7 × 4.3 cm |
| Weight | < 0.9 kg |
| Operating Temperature | –20 °C to +40 °C (continuous) |
| Barcode Support | Standard 1D/2D symbologies |
| Biometric Authentication | Fingerprint login |
| Compliance | FDA 21 CFR Part 11, ISO/IEC 17025 (when used per validated SOP), CE Marked |
| Accessories | Vial adapter, universal tablet holder |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Handheld Raman Spectrometer |
| Model | 1064Defender |
| Spectral Range | 200–2500 cm⁻¹ |
| Spectral Resolution | 8–13 cm⁻¹ |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ±0.1 cm⁻¹ |
| IP Rating | IP68 |
| Compliance | MIL-STD-810H |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Almega XR |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Antaris II |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Antaris Target In-Process Mixing Monitor |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Floor-standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Line Density | 1080, 1667, and 2160 lines/mm |
| Wavelength Range | 200–760 nm |
| Number of Analytical Channels | 80 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL iSpark Plus Series OES |
| Pricing | Available upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Thermo Scientific ARL iSpark Series |
| Price Range | USD 140,000 – 280,000 |
| Instrument Form Factor | Floor-Standing |
| Excitation Source | High-Energy Spark Discharge |
| Detector Configuration | Dual-Detector System (Photomultiplier Tubes + Solid-State CCD Array) |
| Focal Length | Not Applicable (Paschen–Runge Mount with Fixed Optical Path) |
| Groove Density | Not Applicable (Pre-aligned Monochromator Assembly) |
| Wavelength Coverage | 130–800 nm (Simultaneous Full-Spectrum Acquisition) |
| Number of Analytical Channels | Configurable up to 64 Predefined or User-Defined Spectral Lines |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured under Thermo Fisher global quality standards) |
| Model | ARL PERFORM'X |
| Power Options | 1500 W, 2500 W, 4200 W |
| Optical Design | Ultra-Close Coupling Optics (UCCO) |
| Angular Positioning | Gearless digital goniometer with Moiré fringe optical encoder |
| Software Platform | OXSAS v8.x with QuantAS™, UniQuant™, and PetroilQuant™ application packages |
| Compliance | Designed to support GLP/GMP workflows, ASTM E1361, ISO 2936, ISO 8258, USP <233>, and FDA 21 CFR Part 11 audit-trail readiness |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL™ iSpark Plus Series |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific BioMate 3S |
| Optical Design | Double-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | <0.08% T |
| Automation | Automatic Wavelength Selection |
| Compliance | Meets pharmacopeial requirements (USP <857>, EP 2.2.25, JP 2.04) for routine quality control assays |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DXR |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Confocal Micro-Raman Spectrometer |
| Model | DXR2xi |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | 500 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | Better than ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | Thermo Scientific DXR3 Flex Raman Spectrometer |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DXR3 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 3500 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Thermo Scientific DXR3 Raman Microscope |
| Instrument Type | Benchtop Confocal Raman Microscope |
| Spatial Resolution | 1 µm |
| Spectral Range | 50–3500 cm⁻¹ (standard), up to 6000 cm⁻¹ with 532 nm laser |
| Laser Wavelengths | 455 nm, 532 nm (high-brightness & high-power), 633 nm (high-brightness & high-power), 785 nm (high-brightness & high-power) |
| Laser Safety | Class 1 microscope (fiber-coupled accessories: Class 3B) |
| Compliance | 21 CFR Part 11, ASTM E1840, ISO/IEC 17025 (when validated), GLP/GMP-ready |
| Software | OMNIC™ D/S v10+ |
| Detector | Back-illuminated CCD |
| Optical Platform | Olympus research-grade microscope optics |
| Dimensions (W × H × D) | 94 × 61 × 68 cm |
| Weight | 66.5 kg |
| Operating Temperature | 16–27 °C |
| Electrical Requirements | 100–240 V, 47–63 Hz |