Syringe Pump
Filter
Showing 61–72 of 72 results
| Brand | LeadFluid |
|---|---|
| Origin | Hebei, China |
| Model | YD02-01 |
| Pump Type | Microfluidic Syringe Pump |
| Flow Rate Range | 0.001 µL/min – 100 mL/min |
| Accuracy | ≤ ±0.5% |
| Repeatability | ≤ 0.1% |
| Stroke | 140 mm |
| Linear Force | >20 kgf |
| Stroke Resolution | 0.156 µm/µstep |
| Speed Range | 1 µm/min – 150 mm/min |
| Syringe Capacity | 10 µL – 140 mL |
| Display | 4.3-inch Color TFT Touchscreen |
| Communication | RS485, MODBUS RTU Protocol |
| Power Input | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 290 × 205 × 180 mm |
| Weight | 4.4 kg |
| Operating Environment | 5–40 °C, <80% RH |
| Brand | Acmer |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LSP H |
| Instrument Type | Micro-syringe Pump |
| Flow Rate Range | 0.0007 nL/min to 109.136 mL/min |
| Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-21 |
| Instrument Type | Microsyringe Pump |
| Plunger Stroke | 20 mm |
| Full-Rotation Knob Resolution | 500 µm per revolution |
| Volume Displacement per Full Rotation | 10 µL |
| Repeatability | ±0.1 µL (typical, under controlled conditions) |
| Dimensions (W × D × H) | 127–147 mm × 56 mm × 78 mm |
| Weight | 620 g |
| Tubing Length | 1 m |
| Accessories Included | IM-H3 Syringe Holder, O-rings (IMO4), Silicone Gasket (HIO1PK01), Cleaning Rod, Silicone Grease |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | R462 |
| Instrument Type | Micro-syringe Pump |
| Flow Rate Range | 0.0001 µL/min to 102 mL/min |
| Accuracy | ±0.35% |
| Repeatability | ±0.05% |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | Cavro ADP 2 |
| Instrument Type | Micro-syringe Pump |
| Dispensing Range | 5–1000 µL |
| Minimum Increment | 25 nL per step (40,000 steps for 1000 µL) |
| Tip Compatibility | Tecan LiHa disposable tips (10, 50, 200, 1000 µL |
| Liquid Level Detection | Capacitive and pressure-based |
| Communication Interface | RS485 / CAN bus |
| Integrated Diagnostic Algorithms | Bubble detection, clot detection, air aspiration, insufficient liquid volume |
| Tip Handling | Automated tip pickup/ejection with real-time tip status monitoring |
| Cross-contamination | Eliminated via single-use tip architecture |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | Cavro ADP |
| Instrument Type | Micro-syringe Pump |
| Flow Rate | See Product Datasheet |
| Accuracy | <0.25% of Full Scale |
| Repeatability | <0.05% of Full Scale, <0.5% at 10% of Full Scale |
| Dispense Range | <5–1000 µL |
| Step Resolution | 25 nL/step (40,000 steps for 1000 µL) |
| Cross-Contamination | Eliminated via Disposable Tips |
| Tip Handling | Fully Automated — Tip Presence Detection, Pickup & Ejection |
| Compatible Tips | Tecan LiHa Disposable Tips (10, 50, 200, 1000 µL |
| Communication Interface | RS-485 / CAN Bus |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cavro Centris Pump |
| Instrument Type | Microfluidic Syringe Pump |
| Flow Rate Range | 5 nL/s to 5 mL/s |
| Accuracy | <0.25% of full scale |
| Repeatability | <0.05% of full scale |
| Stepping Resolution | 181,490 microsteps |
| Plunger Travel | 30 mm |
| Communication Interfaces | RS-232, RS-485, CAN bus |
| Valve Options | Ceramic (non-distributing: 3-way, 4-way, dual-loop 4-way |
| distributing | 3-way, 6-way, beveled 6-way, 9-way, 12-way) and polymer (same configurations) |
| Syringe Compatibility | 50 µL, 100 µL, 250 µL, 500 µL, 1.0 mL, 2.5 mL, 5.0 mL, 12.5 mL glass syringes |
| Pulse Suppression | Engineered for ultra-low flow pulsation |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | HT-XC |
| Pump Type | Micro-syringe Pump |
| Step Resolution | 3,000 full steps (24,000 microsteps) |
| Valve Configuration | 6-port distribution valve with ceramic rotor |
| Compatible Syringe Volumes | 50 µL, 100 µL, 250 µL, 500 µL, 1.0 mL, 2.5 mL, 5.0 mL |
| Torque Enhancement | ~4× during initialization (low-speed valve actuation), ~3× during normal operation (high-speed valve actuation) |
| Gearbox Integration | Integrated high-ratio planetary gearbox optimized for NGS library preparation workflows |
| Chemical Resistance | Validated for saline solutions and viscous reagents |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | SVP |
| Valve Configurations | 3-, 4-, 6-, 9-, or up to 20-port options (ceramic or polymer rotor/stator) |
| Fluidic Interface | 1/4-28 UNF or M6 threaded ports |
| Control Interface | RS-232, RS-485, CAN bus |
| Power Supply | 24 VDC ±10%, 850 mA max |
| Dimensions | 52.9 × 25 × 50 mm |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–95% RH (non-condensing at 40 °C) |
| Accuracy | <0.25% of full scale |
| Repeatability | <0.05% of full scale |
| Instrument Type | Precision Microfluidic Selector Valve for Syringe Pump Integration |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | Cavro XCalibur Pump |
| Instrument Type | Microfluidic Syringe Pump |
| Flow Rate | As per product datasheet |
| Accuracy | <0.25% of full scale |
| Repeatability | <0.05% of full scale |
| Step Resolution | 3,000 full steps (24,000 microsteps) |
| Plunger Travel | 30 mm |
| Compatible Syringes | 25 µL, 50 µL, 100 µL, 250 µL, 500 µL, 1.0 mL, 2.5 mL, 5.0 mL |
| Valve Options | Non-distributive — 3-way ceramic or plastic |
| Communication Interfaces | RS-232, RS-485, CAN bus |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | Cavro XLP 6000 Pump |
| Pump Type | Precision Microfluidic Syringe Pump |
| Stepping Resolution | 6,000 full steps (48,000 microsteps) |
| Valve Options | Non-distributing 3-way |
| Syringe Volume Range | 50 µL to 50 mL |
| Plunger Stroke | 60 mm |
| Communication Interfaces | RS-232, RS-485, CAN bus |
| Flow Accuracy | < ±0.25% of full scale |
| Flow Repeatability | < ±0.05% of full scale |
| Compliance | Designed for integration into ISO/IEC 17025-compliant laboratories and GLP/GMP environments requiring audit-trail-capable fluid handling |
| Brand | Tecan Cavro |
|---|---|
| Origin | Malaysia |
| Model | Cavro XMP 6000 Pump |
| Pump Type | Multi-Channel Precision Syringe Pump |
| Number of Channels | 2, 4, 6 or 8 (configurable) |
| Stepping Resolution | 6,000 full steps per revolution (48,000 microsteps) |
| Valve Options | Standard 3-way, Bypass-mode 3-way, or 3+1 configuration |
| Syringe Volumes | 50 µL, 100 µL, 250 µL, 500 µL, 1.0 mL, 2.5 mL, 5.0 mL |
| Plunger Stroke | 60 mm |
| Flow Rate Range | As specified in product documentation |
| Accuracy | < ±0.25% of full scale |
| Repeatability | < ±0.05% of full scale |
| Communication Interfaces | RS-232, RS-485, CAN bus |
| Valve Configuration | 1-inlet / 3-outlet manifold-compatible |