Empowering Scientific Discovery

Techcomp Yituo Laboratory Equipment (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPrecisa
OriginSwitzerland
Model330XM
Heating SourceHalogen Lamp
DisplayHigh-Contrast VFD Screen
Weighing SystemIntegrated 320XB Precision Electronic Balance
Sensor TechnologyMFR Electromagnetic Force Restoration
ConstructionFull Die-Cast Aluminum Housing
CalibrationExternal Calibration Mode
ComplianceSupports 3Q Validation (IQ/OQ/PQ)
Regulatory FeaturesReal-Time Clock, Password Protection, Mechanical Safety Interlock
ConnectivityStandard RS232 & USB
Added to wishlistRemoved from wishlist 0
Add to compare
Heating TemperatureAmbient to 300 °C
Heater TypeBand Heater
Sample Volume Capacity≤20 mL
Carrier GasDry Nitrogen or Dry Air
Gas Flow Rate0–300 L/min
Maximum Gas Pressure≤0.8 MPa
Nitrogen Purity≥99.99% (High-Purity Grade)
Desiccant100 g Molecular Sieve
Safety ProtectionsOvertemperature Protection, Overpressure Gas Safety Cut-off
Power SupplyAC 100–240 V, 50/60 Hz, 100 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Analytical
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Instrument TypeLaboratory Benchtop FTIR Spectrometer
Wavenumber Range350–8000 cm⁻¹
Spectral Resolution0.5 cm⁻¹
Signal-to-Noise Ratio (SNR)20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector)
Wavenumber Accuracy±0.05 cm⁻¹
Optical DesignMichelson Interferometer with KBr Beamsplitter and Dynamically Aligned Mirror Drive
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPrecisa
OriginSwitzerland
ModelEM120-HR
Heating SourceHalogen Lamp
DisplayBacklit LCD with Graphical Real-Time Moisture Trend Plot
ConstructionFull Cast-Aluminum Housing
CalibrationFully Automatic Smart Calibration System (SCS)
ComplianceSupports 3Q Validation (IQ/OQ/PQ), GxP-Compliant Real-Time Clock, Multi-Level User Access Control with Password Protection
Software FeaturesBuilt-in Automatic Repeatability Test (ART), Checkweighing, Statistical Analysis
ConnectivityStandard RS232 & USB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelMini-Tau
Spectral DispersionInterference Filter-Based
Instrument TypeSteady-State and Time-Resolved Fluorescence Spectrometer
Slit Width (Spectral Bandpass)0–60 nm
Spectral Resolution50 nm
Signal-to-Noise Ratio3000:1
Wavelength Accuracy±5 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamica
OriginAustralia
ModelDB20R
Optical DesignDual-beam
Detector TypePhotodiode Array
Wavelength Range190–1100 nm
Spectral Bandwidth1.0 nm
Stray Light≤0.05% (at 220 nm with NaI, 340 nm with NaNO₂)
Wavelength Accuracy±0.3 nm
Absorbance Range–3.0 to +3.0 A
Transmittance Range0–300% T
Concentration Range0.000–9.999 units
Scan Speeds10–3600 nm/min (8 selectable rates)
Baseline Stability0.0003 A/hr (500 nm, 2 h)
Noise Level0.0003 A (500 nm, RMS)
Light SourcesDeuterium Lamp + Tungsten-Halogen Lamp
Automatic Lamp Switching325–370 nm
InterfacePC-controlled (no built-in display)
Dimensions (W×D×H)505 × 705 × 225 mm
Net Weight29 kg
Power Supply110–220 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelFLS1000
Dispersion ElementGrating Monochromator
Instrument TypeSteady-State and Time-Resolved Fluorescence Spectrometer
Slit Width (Spectral Bandpass)0–30 nm
Optical Resolution0.05 nm
Sensitivity35,000:1 (RMS method)
Wavelength Accuracy±0.2 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelUV2600
Price RangeUSD 9,800–13,900 (FOB Shanghai)
Optical DesignDual-beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range190–900 nm
Wavelength ScanningMotorized, Software-Controlled
Spectral Bandwidth0.2, 0.5, 1, 2, 5 nm (Auto-Selectable)
Wavelength Accuracy±0.3 nm
Wavelength Repeatability±0.1 nm
Stray Light<0.010% T (at 220 nm, NaI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScion
OriginNetherlands
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model8500-GC
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient to 450 °C
Maximum Ramp Rate170 °C/min
Maximum Cooling Rate150 °C/min
Carrier Gas Flow Range & Control0–1500 mL/min
Carrier Gas Pressure Range & Control0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCION
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic UHPLC System
ModelLC6000-FLD
Instrument TypeUltra-High Performance Liquid Chromatograph with Fluorescence Detection
Flow Rate Range0.001–5.000 mL/min
Maximum Pressure60 MPa
Flow Precision<0.05% RSD
Sample Tray Capacity200 positions (1.5 mL vials)
Optional128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate)
Injection Volume Range0.1–100 µL (standard)
Excitation Wavelength Range200–850 nm
Emission Wavelength Range250–900 nm
Data Acquisition FrequencyMulti-step adjustable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelYLS-B Series
Price RangeUSD 700 – 1,400 (FOB)
Heating MethodHalogen Lamp
Max Capacity60 g (YLS-B Plus) / 20 g (YLS-B Standard)
Readability1 mg (60 g model) / 2 mg (20 g model)
Moisture Resolution0.02–0.1%
Temperature Range50–160 °C (1 °C increments)
Heating Time0–99 min (1 min steps)
DisplayBacklit dot-matrix LCD with dual blue/white background
Data Storage50 sample profiles
InterfaceRS232C
CalibrationExternal weight calibration (20 g for YLS-B
ComplianceSupports IQ/OQ/PQ validation
Power Supply220 VAC (±15%/+10%), 50 Hz
Power Consumption300 W
Operating Environment5–40 °C, 25–85% RH (non-condensing)
Recommended Ambient15–30 °C, 50–75% RH (non-condensing)
Dimensions (W×D×H)458 × 278 × 246 mm
Net Weight5.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandISOTOPX
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPhoenix
Instrument TypeThermal Ionization Mass Spectrometer (TIMS)
Resolution>450
Dynamic Range (ATONA Amplifier)100 V
Mass Drift<20 ppm over 40 min
Faraday Cup Lifetime≥10 years (Phoenix X62)
Vacuum Pumping SpeedHighest among commercial TIMS systems
Sample Capacity20-position rotatable carousel orthogonal to ion beam axis
Optional DetectorsDaly detector, Secondary Electron Multiplier (SEM), Multi-Collector Ion Counter with Conversion Dynode technology
Optional WARP Retarding Field FilterEnables abundance sensitivity <1×10⁻⁸ for ²³⁷U/²³⁸U
Ion Extraction SlitEnlarged for enhanced sensitivity
Focal Plane RotationMotorized, orthogonal to ion trajectory
Sample ChamberStainless steel with multiple auxiliary ports (pre-heating, cryo-trap, oxygen inlet)
SoftwareFully integrated, GLP-compliant, remote operation enabled
Regulatory ComplianceDesigned to support 21 CFR Part 11 audit trails, ISO/IEC 17025 data integrity requirements, and ASTM D7938 (TIMS-based isotope ratio analysis)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamica
OriginAustralia
ModelDB-30
Wavelength Range190–900 nm
Spectral Bandwidth0.1–5.0 nm (6 selectable slits)
Stray Light≤0.01%T (220 nm NaI, 340 nm NaNO₂)
Wavelength Accuracy±0.3 nm
Photometric Accuracy±0.002 Abs (0–0.5 Abs, NIST 900D)
Photometric Repeatability±0.001 Abs (0–0.5 Abs, NIST 930D)
Baseline Flatness±0.001 Abs (200–850 nm)
Baseline Stability0.0004 Abs/hr (500 nm, after 2 hr)
Noise Level±0.0003 Abs (500 nm)
Scan Speeds1–2,000 nm/min (8 selectable rates)
Light SourcesTungsten-halogen & Deuterium lamps with automatic switching (325–370 nm)
DetectorPhotomultiplier tube (PMT)
Control OSWindows XP or Windows 7 Pro
Dimensions710 × 630 × 268 mm (W×D×H)
Net Weight50 kg
Power110–220 V AC, 50/60 Hz, 300 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelFS5 v2
Dispersion ElementGrating
Instrument TypeSteady-State and Time-Resolved Fluorescence Spectrometer
Slit Width (Spectral Bandpass)0–30 nm
Optical Resolution0.01 nm
Sensitivity4000:1 (Signal-to-Noise Ratio)
Wavelength Accuracy±0.5 nm
Excitation SourcesXenon Arc Lamp, Pulsed Laser Diodes (e.g., 375 nm, 405 nm, 445 nm, 485 nm, 635 nm), Optional OPO/UV Laser Systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCION
OriginNetherlands
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelVersa
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Vial Heating Range200 °C, Temperature Increment: 1 °C, Stability: ±0.1 °C
Valve Oven Temperature Range200 °C, Increment: 1 °C
Sample Loop Volume1 mL Silco-coated loop (optional loops: 100 μL, 250 μL, 300 μL, 500 μL, 2 mL, 3 mL, 5 mL)
Vial Capacity20 positions
Vial Size22 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCION
OriginNetherlands
ManufacturerSCION Instruments B.V.
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient to 450 °C
Maximum Ramp Rate170 °C/min
Maximum Cooling Rate150 °C/min
Carrier Gas Flow Range & Control0–1500 mL/min
Carrier Gas Pressure Range & Control0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry
Oven Temperature Range5 °C above ambient to 400 °C
Ramp Rate0.1–39 °C/min
Cooling Rate50 °C/min
Injector Maximum Operating Temperature400 °C
Programmable Temperature Ramping9-step
ColumnSpecified NMHC Separation Column (O₂/CH₄ Resolution Optimized)
Detector OptionsFID, TCD, ECD, FPD, NPD, PID, Micro-TCD
Simultaneous Detector CapacityUp to 3
Analog Outputs3 channels
Digital Output1 RS-232/USB port
DisplayLarge Backlit LCD with Real-Time Dual-Chromatogram View
Control InterfaceTouch-Sensitive Keypad
Electronic Pressure Control (EPC)Optional for Split/Splitless Inlet
Septum PurgeIntegrated for Ghost Peak Suppression
Added to wishlistRemoved from wishlist 0
Add to compare
Heating Temperature RangeAmbient to 350 °C
Heater TypeCartridge Heater
Max. Sample Volume<10 mL
Carrier GasNitrogen or Dry Air (dry air compressor optional)
Gas Flow Rate30–300 L/min
Inlet Pressure≤0.8 MPa
DesiccantMolecular Sieve
Power SupplyAC 100–240 V, 50/60 Hz, 100 VA
Dimensions (W×D×H)220 × 430 × 200 mm
WeightApprox. 8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelRMS1000
Spectral Range50–30000 cm⁻¹
Spectral Resolution≤0.1 cm⁻¹ (FWHM) at ≥800 mm focal length
Spatial ResolutionXY ≤ 0.5 µm, Z ≤ 1 µm
Minimum Wavenumber50 cm⁻¹
Spectral Reproducibility≤ ±0.02 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
ManufacturerYes
TypeDomestic
ModelMaxTira20Q
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelAQV-2200
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
ModelEV-2000L
PricingAvailable Upon Request
Moisture Evaporation MethodAzeotropic Distillation with Inert Carrier Gas
Heating RangeAmbient to 200 °C
Heater TypeBand Heater
Max Sample Volume≤10 mL
Azeotropic SolventToluene or Xylene (5–10 mL per analysis)
Carrier GasNitrogen or Dry Compressed Air (optional integrated air dryer/pump available)
Gas Flow Rate30–300 L/min
Inlet Pressure≤0.8 MPa
DesiccantMolecular Sieve (4 Å)
Power SupplyAC 100–240 V, 50/60 Hz, 150 VA
Dimensions (W×D×H)220 × 370 × 265 mm
Net Weight~7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSteady-State Fluorescence Spectrometer
Wavelength Dispersion ElementHolographic Grating
Slit Width (Spectral Bandpass)1.0–20.0 nm
Optical Resolution0.2 nm
Sensitivity1200:1 (RMS), 15,000:1 (RMS with Background Subtraction)
Wavelength Accuracy±2 nm
Excitation SourcePulsed Xenon Arc Lamp
PMT Detection RangeUp to 900 nm
Maximum Scan Speed30,000 nm/min
SoftwareFL Analyst (English & Chinese GUI)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Analytical
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelDB30
Instrument ArchitectureDual-Beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm
Wavelength Repeatability±0.1 nm
Spectral Bandwidth0.5, 1.0, 1.5, 2.0, 4.0 nm
Stray Light≤0.1%
Automation LevelAutomatic Wavelength Scanning
Scan SpeedUp to 6000 nm/min
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0