- All
- Favorite
- Popular
- Most rated
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | 330XM |
| Heating Source | Halogen Lamp |
| Display | High-Contrast VFD Screen |
| Weighing System | Integrated 320XB Precision Electronic Balance |
| Sensor Technology | MFR Electromagnetic Force Restoration |
| Construction | Full Die-Cast Aluminum Housing |
| Calibration | External Calibration Mode |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ) |
| Regulatory Features | Real-Time Clock, Password Protection, Mechanical Safety Interlock |
| Connectivity | Standard RS232 & USB |
| Heating Temperature | Ambient to 300 °C |
|---|---|
| Heater Type | Band Heater |
| Sample Volume Capacity | ≤20 mL |
| Carrier Gas | Dry Nitrogen or Dry Air |
| Gas Flow Rate | 0–300 L/min |
| Maximum Gas Pressure | ≤0.8 MPa |
| Nitrogen Purity | ≥99.99% (High-Purity Grade) |
| Desiccant | 100 g Molecular Sieve |
| Safety Protections | Overtemperature Protection, Overpressure Gas Safety Cut-off |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 W |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Wavenumber Range | 350–8000 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | 20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ |
| Optical Design | Michelson Interferometer with KBr Beamsplitter and Dynamically Aligned Mirror Drive |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | EM120-HR |
| Heating Source | Halogen Lamp |
| Display | Backlit LCD with Graphical Real-Time Moisture Trend Plot |
| Construction | Full Cast-Aluminum Housing |
| Calibration | Fully Automatic Smart Calibration System (SCS) |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ), GxP-Compliant Real-Time Clock, Multi-Level User Access Control with Password Protection |
| Software Features | Built-in Automatic Repeatability Test (ART), Checkweighing, Statistical Analysis |
| Connectivity | Standard RS232 & USB |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Mini-Tau |
| Spectral Dispersion | Interference Filter-Based |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–60 nm |
| Spectral Resolution | 50 nm |
| Signal-to-Noise Ratio | 3000:1 |
| Wavelength Accuracy | ±5 nm |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DB20R |
| Optical Design | Dual-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Stray Light | ≤0.05% (at 220 nm with NaI, 340 nm with NaNO₂) |
| Wavelength Accuracy | ±0.3 nm |
| Absorbance Range | –3.0 to +3.0 A |
| Transmittance Range | 0–300% T |
| Concentration Range | 0.000–9.999 units |
| Scan Speeds | 10–3600 nm/min (8 selectable rates) |
| Baseline Stability | 0.0003 A/hr (500 nm, 2 h) |
| Noise Level | 0.0003 A (500 nm, RMS) |
| Light Sources | Deuterium Lamp + Tungsten-Halogen Lamp |
| Automatic Lamp Switching | 325–370 nm |
| Interface | PC-controlled (no built-in display) |
| Dimensions (W×D×H) | 505 × 705 × 225 mm |
| Net Weight | 29 kg |
| Power Supply | 110–220 V AC, 50/60 Hz |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FLS1000 |
| Dispersion Element | Grating Monochromator |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.05 nm |
| Sensitivity | 35,000:1 (RMS method) |
| Wavelength Accuracy | ±0.2 nm |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | UV2600 |
| Price Range | USD 9,800–13,900 (FOB Shanghai) |
| Optical Design | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Wavelength Scanning | Motorized, Software-Controlled |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, 5 nm (Auto-Selectable) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | <0.010% T (at 220 nm, NaI |
| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 8500-GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic UHPLC System |
| Model | LC6000-FLD |
| Instrument Type | Ultra-High Performance Liquid Chromatograph with Fluorescence Detection |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Excitation Wavelength Range | 200–850 nm |
| Emission Wavelength Range | 250–900 nm |
| Data Acquisition Frequency | Multi-step adjustable |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YLS-B Series |
| Price Range | USD 700 – 1,400 (FOB) |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g (YLS-B Plus) / 20 g (YLS-B Standard) |
| Readability | 1 mg (60 g model) / 2 mg (20 g model) |
| Moisture Resolution | 0.02–0.1% |
| Temperature Range | 50–160 °C (1 °C increments) |
| Heating Time | 0–99 min (1 min steps) |
| Display | Backlit dot-matrix LCD with dual blue/white background |
| Data Storage | 50 sample profiles |
| Interface | RS232C |
| Calibration | External weight calibration (20 g for YLS-B |
| Compliance | Supports IQ/OQ/PQ validation |
| Power Supply | 220 VAC (±15%/+10%), 50 Hz |
| Power Consumption | 300 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Recommended Ambient | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 458 × 278 × 246 mm |
| Net Weight | 5.5 kg |
| Brand | ISOTOPX |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phoenix |
| Instrument Type | Thermal Ionization Mass Spectrometer (TIMS) |
| Resolution | >450 |
| Dynamic Range (ATONA Amplifier) | 100 V |
| Mass Drift | <20 ppm over 40 min |
| Faraday Cup Lifetime | ≥10 years (Phoenix X62) |
| Vacuum Pumping Speed | Highest among commercial TIMS systems |
| Sample Capacity | 20-position rotatable carousel orthogonal to ion beam axis |
| Optional Detectors | Daly detector, Secondary Electron Multiplier (SEM), Multi-Collector Ion Counter with Conversion Dynode technology |
| Optional WARP Retarding Field Filter | Enables abundance sensitivity <1×10⁻⁸ for ²³⁷U/²³⁸U |
| Ion Extraction Slit | Enlarged for enhanced sensitivity |
| Focal Plane Rotation | Motorized, orthogonal to ion trajectory |
| Sample Chamber | Stainless steel with multiple auxiliary ports (pre-heating, cryo-trap, oxygen inlet) |
| Software | Fully integrated, GLP-compliant, remote operation enabled |
| Regulatory Compliance | Designed to support 21 CFR Part 11 audit trails, ISO/IEC 17025 data integrity requirements, and ASTM D7938 (TIMS-based isotope ratio analysis) |
| Brand | Dynamica |
|---|---|
| Origin | Australia |
| Model | DB-30 |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1–5.0 nm (6 selectable slits) |
| Stray Light | ≤0.01%T (220 nm NaI, 340 nm NaNO₂) |
| Wavelength Accuracy | ±0.3 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs, NIST 900D) |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs, NIST 930D) |
| Baseline Flatness | ±0.001 Abs (200–850 nm) |
| Baseline Stability | 0.0004 Abs/hr (500 nm, after 2 hr) |
| Noise Level | ±0.0003 Abs (500 nm) |
| Scan Speeds | 1–2,000 nm/min (8 selectable rates) |
| Light Sources | Tungsten-halogen & Deuterium lamps with automatic switching (325–370 nm) |
| Detector | Photomultiplier tube (PMT) |
| Control OS | Windows XP or Windows 7 Pro |
| Dimensions | 710 × 630 × 268 mm (W×D×H) |
| Net Weight | 50 kg |
| Power | 110–220 V AC, 50/60 Hz, 300 VA |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FS5 v2 |
| Dispersion Element | Grating |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.01 nm |
| Sensitivity | 4000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.5 nm |
| Excitation Sources | Xenon Arc Lamp, Pulsed Laser Diodes (e.g., 375 nm, 405 nm, 445 nm, 485 nm, 635 nm), Optional OPO/UV Laser Systems |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Versa |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | 200 °C, Temperature Increment: 1 °C, Stability: ±0.1 °C |
| Valve Oven Temperature Range | 200 °C, Increment: 1 °C |
| Sample Loop Volume | 1 mL Silco-coated loop (optional loops: 100 μL, 250 μL, 300 μL, 500 μL, 2 mL, 3 mL, 5 mL) |
| Vial Capacity | 20 positions |
| Vial Size | 22 mL |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments B.V. |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | 5 °C above ambient to 400 °C |
| Ramp Rate | 0.1–39 °C/min |
| Cooling Rate | 50 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Programmable Temperature Ramping | 9-step |
| Column | Specified NMHC Separation Column (O₂/CH₄ Resolution Optimized) |
| Detector Options | FID, TCD, ECD, FPD, NPD, PID, Micro-TCD |
| Simultaneous Detector Capacity | Up to 3 |
| Analog Outputs | 3 channels |
| Digital Output | 1 RS-232/USB port |
| Display | Large Backlit LCD with Real-Time Dual-Chromatogram View |
| Control Interface | Touch-Sensitive Keypad |
| Electronic Pressure Control (EPC) | Optional for Split/Splitless Inlet |
| Septum Purge | Integrated for Ghost Peak Suppression |
| Heating Temperature Range | Ambient to 350 °C |
|---|---|
| Heater Type | Cartridge Heater |
| Max. Sample Volume | <10 mL |
| Carrier Gas | Nitrogen or Dry Air (dry air compressor optional) |
| Gas Flow Rate | 30–300 L/min |
| Inlet Pressure | ≤0.8 MPa |
| Desiccant | Molecular Sieve |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 VA |
| Dimensions (W×D×H) | 220 × 430 × 200 mm |
| Weight | Approx. 8 kg |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RMS1000 |
| Spectral Range | 50–30000 cm⁻¹ |
| Spectral Resolution | ≤0.1 cm⁻¹ (FWHM) at ≥800 mm focal length |
| Spatial Resolution | XY ≤ 0.5 µm, Z ≤ 1 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.02 cm⁻¹ |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | MaxTira20Q |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AQV-2200 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EV-2000L |
| Pricing | Available Upon Request |
| Moisture Evaporation Method | Azeotropic Distillation with Inert Carrier Gas |
| Heating Range | Ambient to 200 °C |
| Heater Type | Band Heater |
| Max Sample Volume | ≤10 mL |
| Azeotropic Solvent | Toluene or Xylene (5–10 mL per analysis) |
| Carrier Gas | Nitrogen or Dry Compressed Air (optional integrated air dryer/pump available) |
| Gas Flow Rate | 30–300 L/min |
| Inlet Pressure | ≤0.8 MPa |
| Desiccant | Molecular Sieve (4 Å) |
| Power Supply | AC 100–240 V, 50/60 Hz, 150 VA |
| Dimensions (W×D×H) | 220 × 370 × 265 mm |
| Net Weight | ~7 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Dispersion Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 1.0–20.0 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | 1200:1 (RMS), 15,000:1 (RMS with Background Subtraction) |
| Wavelength Accuracy | ±2 nm |
| Excitation Source | Pulsed Xenon Arc Lamp |
| PMT Detection Range | Up to 900 nm |
| Maximum Scan Speed | 30,000 nm/min |
| Software | FL Analyst (English & Chinese GUI) |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DB30 |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 0.5, 1.0, 1.5, 2.0, 4.0 nm |
| Stray Light | ≤0.1% |
| Automation Level | Automatic Wavelength Scanning |
| Scan Speed | Up to 6000 nm/min |
Show next