| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 8500-GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic UHPLC System |
| Model | LC6000-FLD |
| Instrument Type | Ultra-High Performance Liquid Chromatograph with Fluorescence Detection |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Excitation Wavelength Range | 200–850 nm |
| Emission Wavelength Range | 250–900 nm |
| Data Acquisition Frequency | Multi-step adjustable |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments B.V. |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | 5 °C above ambient to 400 °C |
| Ramp Rate | 0.1–39 °C/min |
| Cooling Rate | 50 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Programmable Temperature Ramping | 9-step |
| Column | Specified NMHC Separation Column (O₂/CH₄ Resolution Optimized) |
| Detector Options | FID, TCD, ECD, FPD, NPD, PID, Micro-TCD |
| Simultaneous Detector Capacity | Up to 3 |
| Analog Outputs | 3 channels |
| Digital Output | 1 RS-232/USB port |
| Display | Large Backlit LCD with Real-Time Dual-Chromatogram View |
| Control Interface | Touch-Sensitive Keypad |
| Electronic Pressure Control (EPC) | Optional for Split/Splitless Inlet |
| Septum Purge | Integrated for Ghost Peak Suppression |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Techcomp IC1020 Ion Chromatograph |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 42 MPa |
| Flow Rate Range | 0.001–12.000 mL/min |
| Eluent Flow Rate Range | 0.001–12.000 mL/min |
| Operating Temperature Range | Ambient +5°C to 65°C |
| Temperature Stability (Column & Detector) | ≤0.1°C |
| Eluent Concentration Range | 0.01–100 mM KOH (OH⁻-based) |
| Compatible Detectors | Conductivity (standard), Amperometric (optional upgrade) |
| Brand | Scion |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic Instrument |
| Model | 436i |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | –100 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Maximum Cool-Down Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Compass CDS |
| Price Range | USD 35,000 – 85,000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Injection Positions | 100 × 2 mL vials |
| Injection Volume | 0.1–50 µL (standard), 5–2250 µL (optional) |
| Column Oven Temperature Range | Ambient to 85 °C |
| UV-Vis Wavelength Range | 190–600 nm |
| Data Acquisition Frequency | 100 Hz |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Carrier Gas Flow Control Range | 0–1500 mL/min |
| Carrier Gas Pressure Control Range | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose (Benzene-Series & TVOC Analysis) |
| Oven Temperature Range | 5°C above ambient to 400°C |
| Oven Ramp Rate | 0.1–39°C/min |
| Oven Cooling Rate | 50°C/min |
| Injector Maximum Operating Temperature | 400°C |
| Detector | Photoionization Detector (PID) |
| Benzene LOD | 1 ppb |
| Flow Monitoring | Digital Electronic Pressure & Flow Display |
| Software | TVOC-Specific Reverse-Controlled Workstation with Automated Quantitation & Reporting |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Artemis 6000 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.01–10.0 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0–500 µL |
| Autosampler Temperature Control | Yes |
| Post-Column Reactor Temperature Range | Ambient to 180 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Gas Chromatograph |
| Models | 436-GC, 456-GC |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Cooling Rate | ~4.5 min from 400 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Detector Data Acquisition Rate | 600 Hz |
| Column Oven Configuration | Dual-channel (436-GC), Quad-channel (456-GC) |
| Injector Types Supported | Split/Splitless, PTV, Cool-on-Column, Direct Injection |
| Flow Control Mode | Constant Linear Velocity (CLV) |
| System Software | Compass CDS (integrated) |
| Compliance | ASTM, UOP, EN, ISO, GPA, USP methods |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC6000-DAD |
| Instrument Category | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical platform |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Pressure Rating | 60 MPa |
| Flow Precision | <0.05% RSD |
| Sample Tray Capacity | 200 positions (1.5 mL vials) |
| Optional Trays | 128 positions (4 mL vials), 288 positions (96-well microplate), 1152 positions (384-well microplate) |
| Injection Volume Range | 0.1–100 µL (standard) |
| DAD Wavelength Range | 190–900 nm |
| Spectral Acquisition Rate | Multi-step adjustable |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Primaide / Chromaster |
| Pricing | Available Upon Request |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC6000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose analytical platform |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 60 MPa |
| Flow Precision | <0.05% RSD |
| Autosampler Capacity | 200 positions (1.5 mL vials) |
| Optional Configurations | 128 positions (4 mL vials) |
| Injection Volume Range | 0.1–100 µL (standard) |
| Wavelength Ranges | UV-Vis: 190–900 nm |
| DAD | 190–900 nm |
| Fluorescence (FL) | Ex 200–850 nm / Em 250–900 nm |
| Data Acquisition Rate | Multi-step selectable |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | 456i |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | –100 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Maximum Cool-Down Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 5 °C above ambient to 420 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Cool-Down Performance | 350 °C to 50 °C in ≤5 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min (EPC) |
| Carrier Gas Pressure Range & Control | 0–100 psi (EPC) |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–100 psi (EPC) |
| Injector Total Flow Setting Range | 0–100 mL/min (EPC) |
| Electronic Pressure Control Channels | Up to 18 independent gas channels |
| Independent Temperature Zones | 10 |
| Injector Configurations Supported | Up to 3 (including packed-column, split/splitless capillary) |
| Signal Outputs | 3 digital + 3 analog + optional 4th detector interface |
| Method Storage Capacity | 9 methods onboard |
| Power Input Compatibility | 100–240 V AC, 50/60 Hz |
| External Event Inputs | 4 isolated TTL-compatible channels |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Oven Temperature Range | 5 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min |
| Oven Cooling Rate | 50 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Programmable Temperature Ramping | 9-Step |
| Injector Configurations | Up to 3 simultaneous inlets (Split/Splitless with septum purge, Packed Column, and Optional Capillary Inlet) |
| Detector Capacity | Up to 3 detectors installed concurrently |
| Detector Options | FID, TCD, ECD, FPD, NPD, PID, Micro-TCD |
| Signal Outputs | 3 analog channels + 1 digital interface (RS-232/USB) |
| User Interface | Touch-sensitive keypad with large LCD display supporting dual real-time chromatogram overlay |