BrandScion
OriginNetherlands
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Model8500-GC
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient to 450 °C
Maximum Ramp Rate170 °C/min
Maximum Cooling Rate150 °C/min
Carrier Gas Flow Range & Control0–1500 mL/min
Carrier Gas Pressure Range & Control0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCION
OriginNetherlands
ManufacturerSCION Instruments B.V.
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient to 450 °C
Maximum Ramp Rate170 °C/min
Maximum Cooling Rate150 °C/min
Carrier Gas Flow Range & Control0–1500 mL/min
Carrier Gas Pressure Range & Control0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetrochemical Industry
Oven Temperature Range5 °C above ambient to 400 °C
Ramp Rate0.1–39 °C/min
Cooling Rate50 °C/min
Injector Maximum Operating Temperature400 °C
Programmable Temperature Ramping9-step
ColumnSpecified NMHC Separation Column (O₂/CH₄ Resolution Optimized)
Detector OptionsFID, TCD, ECD, FPD, NPD, PID, Micro-TCD
Simultaneous Detector CapacityUp to 3
Analog Outputs3 channels
Digital Output1 RS-232/USB port
DisplayLarge Backlit LCD with Real-Time Dual-Chromatogram View
Control InterfaceTouch-Sensitive Keypad
Electronic Pressure Control (EPC)Optional for Split/Splitless Inlet
Septum PurgeIntegrated for Ghost Peak Suppression
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScion
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic Instrument
Model436i
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range–100 °C to 450 °C
Maximum Ramp Rate150 °C/min
Maximum Cool-Down Rate150 °C/min
Carrier Gas Flow Range & Control0–1500 mL/min
Carrier Gas Pressure Range & Control0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature RangeAmbient to 450 °C
Carrier Gas Flow Control Range0–1500 mL/min
Carrier Gas Pressure Control Range0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose (Benzene-Series & TVOC Analysis)
Oven Temperature Range5°C above ambient to 400°C
Oven Ramp Rate0.1–39°C/min
Oven Cooling Rate50°C/min
Injector Maximum Operating Temperature400°C
DetectorPhotoionization Detector (PID)
Benzene LOD1 ppb
Flow MonitoringDigital Electronic Pressure & Flow Display
SoftwareTVOC-Specific Reverse-Controlled Workstation with Automated Quantitation & Reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScion
OriginNetherlands
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Laboratory Gas Chromatograph
Models436-GC, 456-GC
Temperature Control RangeAmbient +4 °C to 450 °C
Maximum Ramp Rate150 °C/min
Cooling Rate~4.5 min from 400 °C to 50 °C
Carrier Gas Flow Range & Control0–1500 mL/min
Carrier Gas Pressure Range & Control0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1500 mL/min
Detector Data Acquisition Rate600 Hz
Column Oven ConfigurationDual-channel (436-GC), Quad-channel (456-GC)
Injector Types SupportedSplit/Splitless, PTV, Cool-on-Column, Direct Injection
Flow Control ModeConstant Linear Velocity (CLV)
System SoftwareCompass CDS (integrated)
ComplianceASTM, UOP, EN, ISO, GPA, USP methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCION
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
ModelPrimaide / Chromaster
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCION
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic (China)
Model456i
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range–100 °C to 450 °C
Maximum Ramp Rate150 °C/min
Maximum Cool-Down Rate150 °C/min
Carrier Gas Flow Range & Control0–1500 mL/min
Carrier Gas Pressure Range & Control0–150 psi
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–150 psi
Injector Total Flow Setting Range0–1500 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Temperature Control Range5 °C above ambient to 420 °C
Oven Ramp Rate0.1–80 °C/min
Cool-Down Performance350 °C to 50 °C in ≤5 min
Carrier Gas Flow Range & Control0–100 mL/min (EPC)
Carrier Gas Pressure Range & Control0–100 psi (EPC)
Injector Maximum Operating Temperature420 °C
Injector Pressure Setting Range0–100 psi (EPC)
Injector Total Flow Setting Range0–100 mL/min (EPC)
Electronic Pressure Control ChannelsUp to 18 independent gas channels
Independent Temperature Zones10
Injector Configurations SupportedUp to 3 (including packed-column, split/splitless capillary)
Signal Outputs3 digital + 3 analog + optional 4th detector interface
Method Storage Capacity9 methods onboard
Power Input Compatibility100–240 V AC, 50/60 Hz
External Event Inputs4 isolated TTL-compatible channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeBenchtop Laboratory Gas Chromatograph
Application ScopeGeneral-Purpose Analytical Chemistry
Oven Temperature Range5 °C above ambient to 400 °C
Oven Ramp Rate0.1–39 °C/min
Oven Cooling Rate50 °C/min
Injector Maximum Operating Temperature400 °C
Programmable Temperature Ramping9-Step
Injector ConfigurationsUp to 3 simultaneous inlets (Split/Splitless with septum purge, Packed Column, and Optional Capillary Inlet)
Detector CapacityUp to 3 detectors installed concurrently
Detector OptionsFID, TCD, ECD, FPD, NPD, PID, Micro-TCD
Signal Outputs3 analog channels + 1 digital interface (RS-232/USB)
User InterfaceTouch-sensitive keypad with large LCD display supporting dual real-time chromatogram overlay