Empowering Scientific Discovery

Techcomp Yituo Laboratory Equipment (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginFrance
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelBC
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelDNA800
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNuaire
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelNU-543-300S / 400S / 500S / 600S
Instrument TypeClass II A2 Biological Safety Cabinet
External Dimensions (L×W×H, mm)1057 / 1362 / 1669 / 1972 × 799 × 1572
Internal Dimensions (L×W×H, mm)873 / 1178 / 1483 / 1788 × 654 × 724
Filter Efficiency≥99.995% at 0.3 µm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKURABO
OriginJapan
ModelAUTO24S
Automation LevelDedicated Fully Automatic
Sample Throughput1–24 samples per run
Sample Volume Range20–200 µL
Processing Time (Blood)~30 min for 24 samples
Processing Time (Tissue)~40 min for 24 samples
Membrane Thickness80 µm
DNA Fragment Size Range175 bp – 97 kb
Purity (A260/A280)>1.7
Elution PrinciplePressure-driven membrane filtration (no centrifugation, no magnetic beads)
Integrated UV SterilizationYes
On-board Lysis HeatingYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginFrance
ModelBio-Memory
Temperature Range−86 °C
InsulationFull-enclosure Vacuum Insulation Panels (VIP)
VIP Thermal Conductivity<0.005 W/(m·K)
Wall Thickness80 mm
Energy Consumption Reduction15%
Power-Outage Hold Time Increase22%
Internal Volume Gain vs. Conventional ULT+20–30%
ComplianceRoHS-compliant, ODS-free manufacturing
Configuration OptionsUpright, Horizontal, Benchtop
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginFrance
ModelVSHIPPER
ConstructionAerospace-grade aluminum alloy
Intended UseShort-to-medium duration biological sample transport (including air freight)
Static Hold TimeUp to 10 days (typical, dependent on ambient conditions and fill level)
Capacity10–30 L liquid nitrogen (model-dependent)
Sample AccessTop-loading with porous cryo-absorbent liner for controlled LN₂ release and reduced boil-off during access
ComplianceIATA PI 650 compliant for air transport of biological substances
CertificationCE-marked per EU Pressure Equipment Directive (PED 2014/68/EU) for non-pressurized cryogenic vessels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginFrance
ModelVoyager
Capacity Range200–786 L
Sample Capacity10,400–38,400 × 2 mL Cryovials
Storage ModeDual-phase (Liquid & Vapor)
Neck OpeningWide-mouth
Evaporation RateOptimized Low-loss Design
Monitoring SystemCryoMemo Integrated Temperature & Level Monitoring
ConstructionMedical-grade 304/316 Stainless Steel
ComplianceDesigned to meet ISO 13485 principles for medical device storage environments
Intended UseLong-term cryopreservation of biological specimens in GxP-regulated settings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKURABO
OriginJapan
ModelQuickGene-610L
Sample Throughput1–6 samples per run
Input VolumeUp to 2 mL whole blood
DNA Yield>50 µg from 2 mL whole blood
Purity (A260/A280)DNA >1.7, RNA >1.8
Membrane Thickness80 µm
Processing Time~12 min for 6 whole blood samples
Dimensions448 W × 332 D × 398 H mm
Weight~24 kg
OperationPressure-driven, centrifuge-free, magnetic bead-free
Compatible KitQuickGene DNA Blood Kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginUSA
Manufacturer AuthorizationAuthorized Distributor
Import StatusImported
ModelXT Series
Price RangeUSD 6,800 – 13,500
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamica
ModelEHS-530
Cabinet ClassClass II, Type A2
Construction Material304 Stainless Steel Interior (One-Piece Seamless Welded)
External Dimensions (L×W×H)1950 × 750 × 2100 mm
Internal Work Area Dimensions (L×W×H)1862 × 574 × 628 mm
HEPA/ULPA Filtration Efficiency≥99.9995% @ 0.12 µm
Airflow SystemRecirculating (70% re-circulated, 30% exhausted via dedicated duct or thimble connection)
Motor TypeBrushless DC ECM Motor with Variable Speed Control
Control InterfaceDynaAir Color Touchscreen Controller with Real-Time Airflow Monitoring
SensorHigh-Sensitivity Thermal Anemometer for Inflow & Downflow Velocity Detection
ComplianceEN 12469:2000, NSF/ANSI 49-2022, ISO 14644-1 Class 5 (ISO Class 5 Equivalent), GLP-Ready Configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKurabo
OriginJapan
ModelAUTO12S
Automation LevelDedicated Fully Automated
Sample Throughput per Run1–12 samples
Sample Volume Range20–200 µL
Processing Time per Batch20–40 minutes
Membrane Thickness80 µm
Elution VolumeAdjustable (50–200 µL)
DNA Fragment Size Range175 bp – 97 kb
Purity (A260/A280)>1.7
Integrated UV DecontaminationYes
On-board Thermal LysisYes
FootprintBenchtop, Compact Design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKURABO
OriginJapan
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelGF-Q150
Instrument TypeReal-Time Fluorescent Quantitative PCR System
Sample Throughput10-well
Heating Rate8°C/sec
Temperature Accuracy±0.5°C
Inter-Well Temperature Uniformity±0.5°C
Reaction Volume10 µL
Operating Temperature Range (RT-PCR)35–65°C
PCR Temperature Range20–99°C (1.0°C increment)
Display4-line LCD
Built-in Protocols12
Power InputAC 100–230 V, 50/60 Hz (DC 12 V input)
Dimensions (W×L×H)20 × 20 × 12.5 cm
Weight≤3.2 kg
Data Analysis ModesReal-time amplification curves, qualitative positive/negative calling, melting curve analysis, ΔCT and ΔΔCT-based gene expression quantification
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMVE XC
Price RangeUSD $1,300 – $2,600
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
ModelOrigin
ConstructionStainless Steel
OriginFrance
Capacity Range500–1636 L
Sample Storage Capacity27,300–90,400 × 1.2/2 mL Cryovials
Storage ModeDual-phase (Liquid & Vapor)
Evaporation RateLow (Optimized Vacuum Insulation)
Optional AccessoriesAluminum Rotating Rack, CryoMemo Monitoring System
ComplianceDesigned for GLP/GMP-aligned biobanking workflows
Intended UseLong-term cryopreservation of biological specimens
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCryoSystem 750 / 2000 / 4000 / 6000
Price RangeUSD $2,500 – $6,200
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginFrance
Manufacturer AuthorizationAuthorized Distributor
Import StatusImported
ModelGT
PricingUpon Request
LN₂ Capacity2–40 L
Sample Storage Capacity150–7,300 × 0.5 mL Straws
Static Hold Time25–350 days
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKURABO
OriginJapan
Manufacturer StatusAuthorized Distributor
Product OriginImported
Modelmini480
Price RangeUSD 6,800–13,600 (est.)
Automation LevelSemi-Automated Assistant
Throughput1–48 samples per run
Sample Volume Range20–200 µL
Processing Time per Run20–40 minutes
Membrane Thickness80 µm
Elution Yieldup to 5 µg DNA from 200 µL whole blood
PurityDNA A260/A280 > 1.7
Workflow StagesBinding, Washing, Elution (3-pressure-step protocol)
FootprintBenchtop-compatible
Optional Modules2 mL tube handling (8-channel), high-volume sample processing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKurabo
OriginJapan
Manufacturer StatusAuthorized Distributor
Product OriginImported
Modelmini8L
Price RangeUSD 7,000–14,000 (FOB)
Automation LevelSemi-Automatic Assisted
Sample Throughput per Run1–8 samples
Sample Volume Range20–200 µL
Processing Time per Batch10–45 minutes
Membrane Thickness80 µm
Elution VolumeAdjustable (50–200 µL)
Typical DNA YieldUp to 50 µg from 2 mL whole blood
Purity (DNA A₂₆₀/A₂₈₀)>1.7
Extraction PrinciplePressure-Driven Vacuum Filtration via Porous Membrane
Compatible Sample TypesOropharyngeal swabs, whole blood, plasma/serum, cultured cells, fresh/frozen tissue, bacteria, fungi, and microbial lysates
FootprintBenchtop-Optimized (W × D × H: 280 × 320 × 260 mm)
Weight8.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNuAire
OriginUSA
ModelNU-543
Cabinet ClassClass II, Type A2
External Dimensions (L×W×H, mm)1057/1362/1669/1972 × 799 × 1572
Internal Dimensions (L×W×H, mm)873/1178/1483/1788 × 654 × 724
HEPA Filter Efficiency≥99.995% at 0.3 µm
Airflow Configuration70% recirculated (re-circulated after dual-stage HEPA filtration), 30% exhausted (ducted or via thimble connection)
ComplianceNSF/ANSI 49-2022, EN 12469:2000, ISO 14644-1 Class 5 (ISO Class 5 equivalent for work area)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginFrance
ModelTR Series
Construction MaterialAerospace-Grade Aluminum Alloy
Vessel TypeStatic, Non-Pressurized Liquid Nitrogen Dewar
Intended UseLong-Term Biological Sample Storage at –196 °C
Regulatory ContextDesigned for GLP/GMP-Compliant Environments
ComplianceMeets ISO 23775-1:2022 (Cryogenic Vessels — Part 1: Design and Construction)
Safety CertificationCE Marked per PED 2014/68/EU (Pressure Equipment Directive) for auxiliary pressure systems (e.g., optional LN₂ transfer pumps)
Capacity Range10 L to 100 L (nominal static hold time: 12–120 days depending on model and ambient conditions)
Evaporation Rate0.12–0.85 L/day (model-dependent, measured at 20 °C ambient, 50% fill level)
External DimensionsØ220–Ø520 mm × H500–H1200 mm
Net Weight8.5–42 kg (empty, aluminum-only configuration)
Neck Tube Diameter50–125 mm
Accessories SupportedProgrammable LN₂ Level Sensors, Auto-Fill Systems, RFID Sample Rack Integration Kits, Temperature Monitoring Probes (–200 °C to +85 °C), Locking Lid Assemblies
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginUnited Kingdom
ModelPolaris
Capacity Range5,200–94,500 × 2 mL Cryovials
ConstructionMedical-Grade Stainless Steel
Cooling ModeVapor-Phase Storage
LN₂ Evaporation RateOptimized Low-Loss Design
Control InterfaceCryoLog Color Touchscreen Display
SecurityThree-Tier User Authentication & Audit Trail Logging
ComplianceDesigned for GLP/GMP-aligned biobanking environments
CertificationCE-marked per EU Medical Device Regulation (MDR) Annex I essential requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelP3
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNUAIRE
OriginUSA
ModelNU-5800 Series
Temperature Range & AccuracyAmbient to 55°C
Temperature Uniformity±0.35°C
Humidity Range & Accuracy5–90% RH
Capacity235 L (not lbs — corrected per industry standard
Chamber ConstructionSeamless 304 stainless steel interior
Humidity Recovery≤15 min (from door opening)
CO₂ ControlIR sensor, 0–20% range, ±0.1% accuracy
Sterilization OptionsIntegrated dry-heat (180°C) and steam-humidity (≥90°C, 95% RH) cycles
FiltrationDual-stage HEPA (99.99% @ 0.3 µm) recirculating air system
ComplianceFDA-listed device, ISO 13485-manufactured, CE-marked, compliant with ISO 5, USP <797>, and GLP/GMP environmental monitoring requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFroilabo
OriginFrance
ModelBM 175 / BM 340 / BM 515 / BM 690 / BM 1000
Instrument TypeUpright
Net Capacity176 L to 1011 L
Inner Dimensions (W×D×H mm)452×630×620 to 765×920×1436
External Dimensions (W×D×H mm)875×712×1330 to 1200×1004×2000
Power Supply220 V AC, 50 Hz
Rated Power Consumption400 W
Noise Level<55 dBA
RefrigerantCFC-free & HCFC-free blend (R404A/R290 hybrid or equivalent)
Temperature Range–86 °C standard operating setpoint (stable operation from –80 °C to –86 °C)
Temperature Uniformity±1 °C (at –80 °C, measured per IEC 61000-4-2 and ISO 15502 protocols)
InsulationSix-sided Vacuum Insulation Panel (VIP) core with polyurethane foam secondary layer
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0