- All
- Favorite
- Popular
- Most rated
| Brand | Froilabo |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | BC |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DNA800 |
| Pricing | Available Upon Request |
| Brand | Nuaire |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | NU-543-300S / 400S / 500S / 600S |
| Instrument Type | Class II A2 Biological Safety Cabinet |
| External Dimensions (L×W×H, mm) | 1057 / 1362 / 1669 / 1972 × 799 × 1572 |
| Internal Dimensions (L×W×H, mm) | 873 / 1178 / 1483 / 1788 × 654 × 724 |
| Filter Efficiency | ≥99.995% at 0.3 µm |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Model | AUTO24S |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput | 1–24 samples per run |
| Sample Volume Range | 20–200 µL |
| Processing Time (Blood) | ~30 min for 24 samples |
| Processing Time (Tissue) | ~40 min for 24 samples |
| Membrane Thickness | 80 µm |
| DNA Fragment Size Range | 175 bp – 97 kb |
| Purity (A260/A280) | >1.7 |
| Elution Principle | Pressure-driven membrane filtration (no centrifugation, no magnetic beads) |
| Integrated UV Sterilization | Yes |
| On-board Lysis Heating | Yes |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Bio-Memory |
| Temperature Range | −86 °C |
| Insulation | Full-enclosure Vacuum Insulation Panels (VIP) |
| VIP Thermal Conductivity | <0.005 W/(m·K) |
| Wall Thickness | 80 mm |
| Energy Consumption Reduction | 15% |
| Power-Outage Hold Time Increase | 22% |
| Internal Volume Gain vs. Conventional ULT | +20–30% |
| Compliance | RoHS-compliant, ODS-free manufacturing |
| Configuration Options | Upright, Horizontal, Benchtop |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | VSHIPPER |
| Construction | Aerospace-grade aluminum alloy |
| Intended Use | Short-to-medium duration biological sample transport (including air freight) |
| Static Hold Time | Up to 10 days (typical, dependent on ambient conditions and fill level) |
| Capacity | 10–30 L liquid nitrogen (model-dependent) |
| Sample Access | Top-loading with porous cryo-absorbent liner for controlled LN₂ release and reduced boil-off during access |
| Compliance | IATA PI 650 compliant for air transport of biological substances |
| Certification | CE-marked per EU Pressure Equipment Directive (PED 2014/68/EU) for non-pressurized cryogenic vessels |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Voyager |
| Capacity Range | 200–786 L |
| Sample Capacity | 10,400–38,400 × 2 mL Cryovials |
| Storage Mode | Dual-phase (Liquid & Vapor) |
| Neck Opening | Wide-mouth |
| Evaporation Rate | Optimized Low-loss Design |
| Monitoring System | CryoMemo Integrated Temperature & Level Monitoring |
| Construction | Medical-grade 304/316 Stainless Steel |
| Compliance | Designed to meet ISO 13485 principles for medical device storage environments |
| Intended Use | Long-term cryopreservation of biological specimens in GxP-regulated settings |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Model | QuickGene-610L |
| Sample Throughput | 1–6 samples per run |
| Input Volume | Up to 2 mL whole blood |
| DNA Yield | >50 µg from 2 mL whole blood |
| Purity (A260/A280) | DNA >1.7, RNA >1.8 |
| Membrane Thickness | 80 µm |
| Processing Time | ~12 min for 6 whole blood samples |
| Dimensions | 448 W × 332 D × 398 H mm |
| Weight | ~24 kg |
| Operation | Pressure-driven, centrifuge-free, magnetic bead-free |
| Compatible Kit | QuickGene DNA Blood Kit |
| Brand | Froilabo |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | XT Series |
| Price Range | USD 6,800 – 13,500 |
| Brand | Dynamica |
|---|---|
| Model | EHS-530 |
| Cabinet Class | Class II, Type A2 |
| Construction Material | 304 Stainless Steel Interior (One-Piece Seamless Welded) |
| External Dimensions (L×W×H) | 1950 × 750 × 2100 mm |
| Internal Work Area Dimensions (L×W×H) | 1862 × 574 × 628 mm |
| HEPA/ULPA Filtration Efficiency | ≥99.9995% @ 0.12 µm |
| Airflow System | Recirculating (70% re-circulated, 30% exhausted via dedicated duct or thimble connection) |
| Motor Type | Brushless DC ECM Motor with Variable Speed Control |
| Control Interface | DynaAir Color Touchscreen Controller with Real-Time Airflow Monitoring |
| Sensor | High-Sensitivity Thermal Anemometer for Inflow & Downflow Velocity Detection |
| Compliance | EN 12469:2000, NSF/ANSI 49-2022, ISO 14644-1 Class 5 (ISO Class 5 Equivalent), GLP-Ready Configuration |
| Brand | Kurabo |
|---|---|
| Origin | Japan |
| Model | AUTO12S |
| Automation Level | Dedicated Fully Automated |
| Sample Throughput per Run | 1–12 samples |
| Sample Volume Range | 20–200 µL |
| Processing Time per Batch | 20–40 minutes |
| Membrane Thickness | 80 µm |
| Elution Volume | Adjustable (50–200 µL) |
| DNA Fragment Size Range | 175 bp – 97 kb |
| Purity (A260/A280) | >1.7 |
| Integrated UV Decontamination | Yes |
| On-board Thermal Lysis | Yes |
| Footprint | Benchtop, Compact Design |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | GF-Q150 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 10-well |
| Heating Rate | 8°C/sec |
| Temperature Accuracy | ±0.5°C |
| Inter-Well Temperature Uniformity | ±0.5°C |
| Reaction Volume | 10 µL |
| Operating Temperature Range (RT-PCR) | 35–65°C |
| PCR Temperature Range | 20–99°C (1.0°C increment) |
| Display | 4-line LCD |
| Built-in Protocols | 12 |
| Power Input | AC 100–230 V, 50/60 Hz (DC 12 V input) |
| Dimensions (W×L×H) | 20 × 20 × 12.5 cm |
| Weight | ≤3.2 kg |
| Data Analysis Modes | Real-time amplification curves, qualitative positive/negative calling, melting curve analysis, ΔCT and ΔΔCT-based gene expression quantification |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MVE XC |
| Price Range | USD $1,300 – $2,600 |
| Brand | Froilabo |
|---|---|
| Model | Origin |
| Construction | Stainless Steel |
| Origin | France |
| Capacity Range | 500–1636 L |
| Sample Storage Capacity | 27,300–90,400 × 1.2/2 mL Cryovials |
| Storage Mode | Dual-phase (Liquid & Vapor) |
| Evaporation Rate | Low (Optimized Vacuum Insulation) |
| Optional Accessories | Aluminum Rotating Rack, CryoMemo Monitoring System |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |
| Intended Use | Long-term cryopreservation of biological specimens |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoSystem 750 / 2000 / 4000 / 6000 |
| Price Range | USD $2,500 – $6,200 |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | GT |
| Pricing | Upon Request |
| LN₂ Capacity | 2–40 L |
| Sample Storage Capacity | 150–7,300 × 0.5 mL Straws |
| Static Hold Time | 25–350 days |
| Brand | KURABO |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | mini480 |
| Price Range | USD 6,800–13,600 (est.) |
| Automation Level | Semi-Automated Assistant |
| Throughput | 1–48 samples per run |
| Sample Volume Range | 20–200 µL |
| Processing Time per Run | 20–40 minutes |
| Membrane Thickness | 80 µm |
| Elution Yield | up to 5 µg DNA from 200 µL whole blood |
| Purity | DNA A260/A280 > 1.7 |
| Workflow Stages | Binding, Washing, Elution (3-pressure-step protocol) |
| Footprint | Benchtop-compatible |
| Optional Modules | 2 mL tube handling (8-channel), high-volume sample processing |
| Brand | Kurabo |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | mini8L |
| Price Range | USD 7,000–14,000 (FOB) |
| Automation Level | Semi-Automatic Assisted |
| Sample Throughput per Run | 1–8 samples |
| Sample Volume Range | 20–200 µL |
| Processing Time per Batch | 10–45 minutes |
| Membrane Thickness | 80 µm |
| Elution Volume | Adjustable (50–200 µL) |
| Typical DNA Yield | Up to 50 µg from 2 mL whole blood |
| Purity (DNA A₂₆₀/A₂₈₀) | >1.7 |
| Extraction Principle | Pressure-Driven Vacuum Filtration via Porous Membrane |
| Compatible Sample Types | Oropharyngeal swabs, whole blood, plasma/serum, cultured cells, fresh/frozen tissue, bacteria, fungi, and microbial lysates |
| Footprint | Benchtop-Optimized (W × D × H: 280 × 320 × 260 mm) |
| Weight | 8.2 kg |
| Brand | NuAire |
|---|---|
| Origin | USA |
| Model | NU-543 |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H, mm) | 1057/1362/1669/1972 × 799 × 1572 |
| Internal Dimensions (L×W×H, mm) | 873/1178/1483/1788 × 654 × 724 |
| HEPA Filter Efficiency | ≥99.995% at 0.3 µm |
| Airflow Configuration | 70% recirculated (re-circulated after dual-stage HEPA filtration), 30% exhausted (ducted or via thimble connection) |
| Compliance | NSF/ANSI 49-2022, EN 12469:2000, ISO 14644-1 Class 5 (ISO Class 5 equivalent for work area) |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | TR Series |
| Construction Material | Aerospace-Grade Aluminum Alloy |
| Vessel Type | Static, Non-Pressurized Liquid Nitrogen Dewar |
| Intended Use | Long-Term Biological Sample Storage at –196 °C |
| Regulatory Context | Designed for GLP/GMP-Compliant Environments |
| Compliance | Meets ISO 23775-1:2022 (Cryogenic Vessels — Part 1: Design and Construction) |
| Safety Certification | CE Marked per PED 2014/68/EU (Pressure Equipment Directive) for auxiliary pressure systems (e.g., optional LN₂ transfer pumps) |
| Capacity Range | 10 L to 100 L (nominal static hold time: 12–120 days depending on model and ambient conditions) |
| Evaporation Rate | 0.12–0.85 L/day (model-dependent, measured at 20 °C ambient, 50% fill level) |
| External Dimensions | Ø220–Ø520 mm × H500–H1200 mm |
| Net Weight | 8.5–42 kg (empty, aluminum-only configuration) |
| Neck Tube Diameter | 50–125 mm |
| Accessories Supported | Programmable LN₂ Level Sensors, Auto-Fill Systems, RFID Sample Rack Integration Kits, Temperature Monitoring Probes (–200 °C to +85 °C), Locking Lid Assemblies |
| Brand | Froilabo |
|---|---|
| Origin | United Kingdom |
| Model | Polaris |
| Capacity Range | 5,200–94,500 × 2 mL Cryovials |
| Construction | Medical-Grade Stainless Steel |
| Cooling Mode | Vapor-Phase Storage |
| LN₂ Evaporation Rate | Optimized Low-Loss Design |
| Control Interface | CryoLog Color Touchscreen Display |
| Security | Three-Tier User Authentication & Audit Trail Logging |
| Compliance | Designed for GLP/GMP-aligned biobanking environments |
| Certification | CE-marked per EU Medical Device Regulation (MDR) Annex I essential requirements |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | P3 |
| Pricing | Upon Request |
| Brand | NUAIRE |
|---|---|
| Origin | USA |
| Model | NU-5800 Series |
| Temperature Range & Accuracy | Ambient to 55°C |
| Temperature Uniformity | ±0.35°C |
| Humidity Range & Accuracy | 5–90% RH |
| Capacity | 235 L (not lbs — corrected per industry standard |
| Chamber Construction | Seamless 304 stainless steel interior |
| Humidity Recovery | ≤15 min (from door opening) |
| CO₂ Control | IR sensor, 0–20% range, ±0.1% accuracy |
| Sterilization Options | Integrated dry-heat (180°C) and steam-humidity (≥90°C, 95% RH) cycles |
| Filtration | Dual-stage HEPA (99.99% @ 0.3 µm) recirculating air system |
| Compliance | FDA-listed device, ISO 13485-manufactured, CE-marked, compliant with ISO 5, USP <797>, and GLP/GMP environmental monitoring requirements |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | BM 175 / BM 340 / BM 515 / BM 690 / BM 1000 |
| Instrument Type | Upright |
| Net Capacity | 176 L to 1011 L |
| Inner Dimensions (W×D×H mm) | 452×630×620 to 765×920×1436 |
| External Dimensions (W×D×H mm) | 875×712×1330 to 1200×1004×2000 |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 400 W |
| Noise Level | <55 dBA |
| Refrigerant | CFC-free & HCFC-free blend (R404A/R290 hybrid or equivalent) |
| Temperature Range | –86 °C standard operating setpoint (stable operation from –80 °C to –86 °C) |
| Temperature Uniformity | ±1 °C (at –80 °C, measured per IEC 61000-4-2 and ISO 15502 protocols) |
| Insulation | Six-sided Vacuum Insulation Panel (VIP) core with polyurethane foam secondary layer |