Empowering Scientific Discovery

Techcomp Yituo Laboratory Equipment (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Analytical
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Instrument TypeLaboratory Benchtop FTIR Spectrometer
Wavenumber Range350–8000 cm⁻¹
Spectral Resolution0.5 cm⁻¹
Signal-to-Noise Ratio (SNR)20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector)
Wavenumber Accuracy±0.05 cm⁻¹
Optical DesignMichelson Interferometer with KBr Beamsplitter and Dynamically Aligned Mirror Drive
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelMini-Tau
Spectral DispersionInterference Filter-Based
Instrument TypeSteady-State and Time-Resolved Fluorescence Spectrometer
Slit Width (Spectral Bandpass)0–60 nm
Spectral Resolution50 nm
Signal-to-Noise Ratio3000:1
Wavelength Accuracy±5 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamica
OriginAustralia
ModelDB20R
Optical DesignDual-beam
Detector TypePhotodiode Array
Wavelength Range190–1100 nm
Spectral Bandwidth1.0 nm
Stray Light≤0.05% (at 220 nm with NaI, 340 nm with NaNO₂)
Wavelength Accuracy±0.3 nm
Absorbance Range–3.0 to +3.0 A
Transmittance Range0–300% T
Concentration Range0.000–9.999 units
Scan Speeds10–3600 nm/min (8 selectable rates)
Baseline Stability0.0003 A/hr (500 nm, 2 h)
Noise Level0.0003 A (500 nm, RMS)
Light SourcesDeuterium Lamp + Tungsten-Halogen Lamp
Automatic Lamp Switching325–370 nm
InterfacePC-controlled (no built-in display)
Dimensions (W×D×H)505 × 705 × 225 mm
Net Weight29 kg
Power Supply110–220 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelFLS1000
Dispersion ElementGrating Monochromator
Instrument TypeSteady-State and Time-Resolved Fluorescence Spectrometer
Slit Width (Spectral Bandpass)0–30 nm
Optical Resolution0.05 nm
Sensitivity35,000:1 (RMS method)
Wavelength Accuracy±0.2 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelUV2600
Price RangeUSD 9,800–13,900 (FOB Shanghai)
Optical DesignDual-beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range190–900 nm
Wavelength ScanningMotorized, Software-Controlled
Spectral Bandwidth0.2, 0.5, 1, 2, 5 nm (Auto-Selectable)
Wavelength Accuracy±0.3 nm
Wavelength Repeatability±0.1 nm
Stray Light<0.010% T (at 220 nm, NaI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamica
OriginAustralia
ModelDB-30
Wavelength Range190–900 nm
Spectral Bandwidth0.1–5.0 nm (6 selectable slits)
Stray Light≤0.01%T (220 nm NaI, 340 nm NaNO₂)
Wavelength Accuracy±0.3 nm
Photometric Accuracy±0.002 Abs (0–0.5 Abs, NIST 900D)
Photometric Repeatability±0.001 Abs (0–0.5 Abs, NIST 930D)
Baseline Flatness±0.001 Abs (200–850 nm)
Baseline Stability0.0004 Abs/hr (500 nm, after 2 hr)
Noise Level±0.0003 Abs (500 nm)
Scan Speeds1–2,000 nm/min (8 selectable rates)
Light SourcesTungsten-halogen & Deuterium lamps with automatic switching (325–370 nm)
DetectorPhotomultiplier tube (PMT)
Control OSWindows XP or Windows 7 Pro
Dimensions710 × 630 × 268 mm (W×D×H)
Net Weight50 kg
Power110–220 V AC, 50/60 Hz, 300 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelFS5 v2
Dispersion ElementGrating
Instrument TypeSteady-State and Time-Resolved Fluorescence Spectrometer
Slit Width (Spectral Bandpass)0–30 nm
Optical Resolution0.01 nm
Sensitivity4000:1 (Signal-to-Noise Ratio)
Wavelength Accuracy±0.5 nm
Excitation SourcesXenon Arc Lamp, Pulsed Laser Diodes (e.g., 375 nm, 405 nm, 445 nm, 485 nm, 635 nm), Optional OPO/UV Laser Systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelRMS1000
Spectral Range50–30000 cm⁻¹
Spectral Resolution≤0.1 cm⁻¹ (FWHM) at ≥800 mm focal length
Spatial ResolutionXY ≤ 0.5 µm, Z ≤ 1 µm
Minimum Wavenumber50 cm⁻¹
Spectral Reproducibility≤ ±0.02 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSteady-State Fluorescence Spectrometer
Wavelength Dispersion ElementHolographic Grating
Slit Width (Spectral Bandpass)1.0–20.0 nm
Optical Resolution0.2 nm
Sensitivity1200:1 (RMS), 15,000:1 (RMS with Background Subtraction)
Wavelength Accuracy±2 nm
Excitation SourcePulsed Xenon Arc Lamp
PMT Detection RangeUp to 900 nm
Maximum Scan Speed30,000 nm/min
SoftwareFL Analyst (English & Chinese GUI)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Analytical
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelDB30
Instrument ArchitectureDual-Beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm
Wavelength Repeatability±0.1 nm
Spectral Bandwidth0.5, 1.0, 1.5, 2.0, 4.0 nm
Stray Light≤0.1%
Automation LevelAutomatic Wavelength Scanning
Scan SpeedUp to 6000 nm/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelIR5
Instrument TypeBenchtop Laboratory FTIR Spectrometer
Wavenumber Range350–8000 cm⁻¹
Spectral Resolution0.01 cm⁻¹
Signal-to-Noise Ratio (S/N)20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector)
Wavenumber Accuracy±0.5 cm⁻¹
Detector OptionsStandard DTGS
Software PlatformMiracle™ v5.x
Optional ModuleFT-PL (Fourier Transform Photoluminescence) with Integrated Laser Excitation Source
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelUV1200
Instrument ArchitecturePseudo-Double-Beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Automation LevelAutomatic Wavelength Scanning
Spectral Bandwidth2 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability≤0.3 nm
Stray Light≤0.05%
Display7-inch HD capacitive touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelRM5
Instrument TypeConfocal Raman Microspectrometer
Spectral Range50–15000 cm⁻¹
Spectral Resolution≥1 cm⁻¹ (FWHM)
Spatial ResolutionDown to 1 µm
Low-Wavenumber Cutoff<50 cm⁻¹
Spectral Reproducibility≤0.02 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSteady-State Fluorescence Spectrometer
Wavelength Dispersion ElementGrating
Slit Width (Spectral Bandpass)1.0–20 nm
Optical Resolution0.2 nm
Sensitivity>450:1 (Peak-to-Peak)
Wavelength Accuracy±2.0 nm
Excitation SourceXenon Arc Lamp
Standard PMT RangeUp to 900 nm
Maximum Scan Speed30,000 nm/min
Spectral CorrectionFull-mode (Excitation/Emission/Spectral Response)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelLifeSpec II
Wavelength Dispersion ElementDual Grating Monochromator
Spectral Bandpass (Slit)0–60 nm
Optical Resolution0.01 nm
Sensitivity (Signal-to-Noise Ratio)6000:1
Wavelength Accuracy±0.1 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Analytical
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Instrument TypeSteady-State Fluorescence Spectrometer
Wavelength Range200–900 nm
Excitation SourceXenon Arc Lamp
MonochromatorGrating-Based
Slit WidthAdjustable (Multiple Bandwidths)
Spectral Resolution1.0 nm
Wavelength Accuracy±2.0 nm
Signal-to-Noise Ratio (S/N)15,000:1
Maximum Scan Speed60,000 nm/min
SoftwareSpectracle™
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEdinburgh Instruments
OriginUnited Kingdom
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelLP980
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamica
OriginAustralia
ModelDNAmaster
Optical DesignSingle-beam
Light SourceLong-life xenon lamp
DetectorCCD array
Wavelength Range200–900 nm
Absorbance Range0–4.0 OD
Wavelength Accuracy±1 nm
Slit Width4 nm
Noise~0.005 OD (RMS)
Drift~0.005 OD
Photometric Accuracy±0.01 OD
Photometric Repeatability±0.005 OD
Stray Light0.5% T
Minimum Sample Volume0.5 µL
DNA Detection Limit20 ng/µL
Data StorageInternal memory or SD card
Power Supply110–240 V, 50/60 Hz
Energy-saving ModeYes
Startup Audio Selection7 options
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelUV2500
Price RangeUSD 9,800–13,900 (FOB Shanghai)
Optical DesignDual-Beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Scanning ModeMotorized Auto-Scan
Spectral Bandwidth1.5 nm
Wavelength Accuracy±0.3 nm
Wavelength Repeatability±0.1 nm
Stray Light≤0.05% T at 220 nm and 340 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTechcomp
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument StructureSingle-Beam
Detector TypePhotocell
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Wavelength Repeatability≤0.2 nm
Spectral Bandwidth2 nm
Stray Light≤0.05% T
Automation LevelAutomatic Wavelength Scanning
Display5-inch TFT Color Touchscreen
Optical PlatformIntegrated Die-Cast Optical Base
ComplianceDesigned for GLP-compliant routine analysis
ConnectivityUSB and RS-232 interfaces for PC control and printer output
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamica
OriginAustralia
ModelXB-10 VIS-20
Wavelength Range190–1000 nm (XB-10), 330–1000 nm (VIS-20)
Spectral Bandwidth5 nm (XB-10), 8 nm (VIS-20)
Wavelength Resolution1 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability1 nm
Photometric Accuracy±1% T
Photometric Repeatability0.50% T
Stray Light<0.5% at 220 nm, 340 nm, and 360 nm
Noise0.004 A at 250 nm, 0 A
Absorbance Range–0.3 to 1.999 A
Transmittance Range0–199.9% T
Concentration Range–300 to 1999 (user-selectable resolution: 1, 0.1, 0.01, or 0.001)
Data StorageSD card
Measurement ModesAbsorbance, Transmittance, Concentration, Multi-wavelength, Kinetic (Time Scan), Spectrum Scan
Peak DetectionAutomatic peak/valley identification in spectral scans
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0